Szabolcs Szekeres

Mr. Szabolcs Szekeres

University of Debrecen, Debrecen, Hajdú-Bihar, Hungary
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
SSSzabolcs Szekeres
Szabolcs Szekeres
AKAttila Kostyak
Attila Kostyak
Ferenc SzodraiFerenc Szodrai
Ferenc Szodrai
CICsáky Imre
Csáky Imre
As a result of COVID-19, many office buildings around the world have downsized their employees, but the comfort parameters in the building had to be kept. The facilities operation rearranged the workstations to keep physical distance and placed plexiglass sheets on the desks for physical protection. A series of measurements have been carried out with workstation set-ups to examine the fresh air rate in the occupied zone. The effect of plexiglass sheets placed on the desks was also examined to see how it changes the airflow pattern in the occupied zone. As the sheets act as a barrier, the primary air does not reach the occupied zone, therefore, the fresh air rate is less. To modify the properties of the ceiling diffusers a new air-ventilation service element was developed. This attachment allows modifying the properties of the ceiling diffusers. Simulations were made at the relevant zones to validate the measurements. Based on design software, the fresh air ratio for a standard ceiling swirl diffuser is 2.46 v% (volume percentage). A numerical model was used to show the fresh air ratio with the system elements for the two different table arrangements, which were 18.3 v% and 21.4 v%, respectively.

14 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
AKAttila Kostyak
Attila Kostyak
SSSzabolcs Szekeres
Szabolcs Szekeres
CICsáky Imre
Csáky Imre
Previous studies have shown that the amount of energy consumed by mechanical cooling can be significantly reduced by the indirect evaporative cooling (IEC) process. By increasing the heat recovery efficiency of air handling units (AHUs), sensible cooling performance can be achieved with the IEC process for a significant part of the cooling season. This study determined the sensible cooling performance under which outdoor air conditions can be achieved. With IEC, the indoor humidity load cannot be adequately managed and must be solved by a supplementary cooling system, which may require additional cooling energy. This study shows the effect of the set indoor humidity on the amount of cooling energy required. The increase in energy consumption of the supplementary cooling system has been determined by simulation and for which indoor air conditions the amount of cooling energy used can be optimized if only IEC cooling is used in the air handling unit.

1 December 2024 in Journal of Architectural Engineering
Verified
Journal Article
Open access
AKAttila Kostyák
Attila Kostyák
SSSzabolcs Szekeres
Szabolcs Szekeres
CICsáky Imre
Csáky Imre

1 June 2024 in Journal of Architectural Engineering
Verified
Journal Article
Open access
PDF file
SSSzabolcs Szekeres
Szabolcs Szekeres
AKAttila Kostyák
Attila Kostyák
CICsáky Imre
Csáky Imre
This article presents a study on the capture velocity of local exhaust ventilation (LEV) using a specially designed workstation within a laboratory setting. The workstation featured a workt...

24 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
AKAttila Kostyak
Attila Kostyak
CBCsaba Beres
Csaba Beres
SSSzabolcs Szekeres
Szabolcs Szekeres
CICsáky Imre
Csáky Imre
In this article, energy optimization of the cooling system of IKEA Budaörs is carried out. The cooling system is served by a centrifugal water chiller and includes a large-volume cooling buffer tank. The facility operates the hydraulic system of the buffer storage tank only during the transitional period. The main goal is to reduce energy consumption by changing the operating strategy of the existing system. To test the operating strategies, the operation and the thermal load of the shopping center during the summer season had to be simulated to find the best operation strategy. A hybrid method (real data and calculated values) was used in the simulation. The three operating scenarios examined show that the annual energy consumption and the number of operating hours of the chiller can be reduced by using the buffer tank with the right strategy. In the examined scenarios, a 30% energy improvement was achieved. The possibility of using a buffer tank is significantly limited by the fact that the heat exchangers were sized for low forward water temperatures. By re-sizing the heat exchangers, the utilization of the buffer tank could be considerably improved in conditions close to peak heat load.

21 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
AKAttila Kostyak
Attila Kostyak
SSSzabolcs Szekeres
Szabolcs Szekeres
CICsáky Imre
Csáky Imre
Energy consumption in buildings with large, glazed facades rises markedly in the summer, driven by cooling demands that vary with structural characteristics and external climate conditions. This study is unique in examining daily cooling needs in lightweight and heavyweight constructions, utilizing meteorological data from 782 summer days in Debrecen, Hungary. Unlike standard approaches, which often overlook localized meteorological variables, this analysis focuses on actual “clear sky” scenarios across distinct summer day types: normal, hot, and torrid. The findings indicate that orientation and construction type significantly affect cooling demands, with east-facing rooms demanding up to 14.2% more cooling in lightweight structures and up to 35.8% in heavyweight structures during peak hours (8 a.m. to 4 p.m.). This study reveals that for west-facing facades, extending use beyond 4 p.m. markedly increases energy loads. Furthermore, the cooling demand peak for heavyweight buildings occurs later in the day, driven by their higher thermal capacity. These insights underscore the importance of aligning HVAC system design with operational schedules and building orientation, offering data-driven strategies to enhance energy efficiency in buildings with diverse thermal and solar exposure profiles.