Roto Roto

Roto Roto

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2020 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
RRRoto Roto
Roto Roto
ARAditya Rianjanu
Aditya Rianjanu
ARAnnisa Rahmawati
Annisa Rahmawati
IFInnas Amaliya Fatyadi
Innas Amaliya Fatyadi
NYNursidik Yulianto
Nursidik Yulianto
Kuwat TriyanaKuwat Triyana
Kuwat Triyana

28 June 2019 in Chemosensors
Verified
Journal Article
Open access
PDF file
RRRoto Roto
Roto Roto
BMBella Mellisani
Bella Mellisani
AKAgus Kuncaka
Agus Kuncaka
MMMudasir Mudasir
Mudasir Mudasir
ASAdhitasari Suratman
Adhitasari Suratman
Colorimetric analysis of heavy metal ions can be realized by the aid of Ag nanoparticles to improve the analytical characteristics. The method is based on the localized surface plasmon resonance (LSPR) properties of the Ag nanoparticles (AgNPs). In this work, we applied the AgNPs with the addition of dithizone to further improve the selectivity and sensitivity of Pb2+ analysis. Colorimetric sensing of Pb2+ ions based on the polyvinyl alcohol (PVA)-stabilized-colloidal AgNPs in the presence of dithizone is reported. A linear decrease in the AgNPs LSPR absorbance at 421 nm was observed along with the increase in the Pb2+ concentration in the range of 0.50–10 µg/L. The other ions give a minor change in the LSPR absorbance of colloidal AgNPs. The Pb2+ limit of detection, the limit of quantification, and sensitivity were found to be 0.64 ± 0.04 µg/L, 2.1 ± 0.15 µg/L, 0.0282 ± 0.0040 L/µg (n = 5), respectively. The obtained sensitivity is comparable with that of the immunosensing method. The proposed method could offer a good alternative for colorimetric analysis of Pb2+ ions by using nanoparticles in the presence of ligands, which can improve selectivity.

8 September 2018 in Electronics
Verified
Journal Article
Open access
PDF file
Kuwat TriyanaKuwat Triyana
Kuwat Triyana
ASAgustinus Sembiring
Agustinus Sembiring
ARAditya Rianjanu
Aditya Rianjanu
SHShidiq Nur Hidayat
Shidiq Nur Hidayat
RRRiowirawan Riowirawan
Riowirawan Riowirawan
RRRoto Roto
Roto Roto
Short-chain alcohols are a group of volatile organic compounds (VOCs) that are often found in workplaces and laboratories, as well as medical, pharmaceutical, and food industries. Real-time monitoring of alcohol vapors is essential because exposure to alcohol vapors with concentrations of 0.15–0.30 mg·L−1 may be harmful to human health. This study aims to improve the detection capabilities of quartz crystal microbalance (QCM)-based sensors for the analysis of alcohol vapors. The active layer of chitosan was immobilized onto the QCM substrate through a self-assembled monolayer of L-cysteine using glutaraldehyde as a cross-linking agent. Before alcohol analysis, the QCM sensing chip was exposed to humidity because water vapor significantly interferes with QCM gas sensing. The prepared QCM sensor chip was tested for the detection of four different alcohols: n-propanol, ethanol, isoamyl alcohol, and n-amyl alcohol. For comparison, a non-alcohol of acetone was also tested. The prepared QCM sensing chip is selective to alcohols because of hydrogen bond formation between the hydroxyl groups of chitosan and the analyte. The highest response was achieved when the QCM sensing chip was exposed to n-amyl alcohol vapor, with a sensitivity of about 4.4 Hz·mg−1·L. Generally, the sensitivity of the QCM sensing chip is dependent on the molecular weight of alcohol. Moreover, the developed QCM sensing chips are stable after 10 days of repeated measurements, with a rapid response time of only 26 s. The QCM sensing chip provides an alternative method to established analytical methods such as gas chromatography for the detection of short-chain alcohol vapors.

10 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ARAditya Rianjanu
Aditya Rianjanu
RRRoto Roto
Roto Roto
TJTrisna Julian
Trisna Julian
SHShidiq Nur Hidayat
Shidiq Nur Hidayat
AKAhmad Kusumaatmaja
Ahmad Kusumaatmaja
Kuwat TriyanaKuwat Triyana
Kuwat Triyana
Safrole is the main precursor for producing the amphetamine-type stimulant (ATS) drug, N-methyl-3,4-methylenedioxyamphetamine (MDMA), also known as ecstasy. We devise a polyacrylonitrile (PAN) nanofiber-based quartz crystal microbalance (QCM) for detecting safrole. The PAN nanofibers were fabricated by direct electrospinning to modify the QCM chips. The PAN nanofiber on the QCM chips has a diameter of 240 ± 10 nm. The sensing of safrole by QCM modified with PAN nanofiber shows good reversibility and an apparent sensitivity of 4.6 Hz·L/mg. The proposed method is simple, inexpensive, and convenient for detecting safrole, and can be an alternative to conventional instrumental analytical methods for general volatile compounds.

22 April 2019 in Chemosensors
Verified
Journal Article
Open access
PDF file
ARAditya Rianjanu
Aditya Rianjanu
SHSiti A. Hasanah
Siti A. Hasanah
DNDoni Bowo Nugroho
Doni Bowo Nugroho
AKAhmad Kusumaatmaja
Ahmad Kusumaatmaja
RRRoto Roto
Roto Roto
Kuwat TriyanaKuwat Triyana
Kuwat Triyana
Vapors of volatile organic compounds such as benzene, toluene, and xylene (BTX) may cause health concerns. The sensitive detection of these compounds in air remains challenging. In this study, we reported on modification of the Quartz Crystal Microbalance (QCM) sensing chip using polyvinyl acetate (PVAc) film as active coating for the analysis of BTX vapors. The PVAc film was deposited on the QCM sensing chip surface by a spin coating technique. The morphology of the PVAc films was confirmed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The sensitivities of PVAc based QCM system for benzene, toluene, and xylene analyses were 0.018, 0.041, and 0.081 Hz/ppm, respectively. The high sensitivity of the proposed QCM system for analysis of BTX vapors is believed to be due to the effective interaction between the PVAc film and BTX molecules. The analyte vapor pressure appears to also affect the sensitivity. These data show that the prepared QCM sensor has a low time constant, good reproducibility, and excellent stability. It offers an alternative to the developed methods for detection of BTX and possibly other aromatic hydrocarbons in the air.

12 November 2018 in Indonesian Journal of Chemistry
Verified
Journal Article
Open access
PDF file
RRRoto Roto
Roto Roto
HRHani Prima Rasydta
Hani Prima Rasydta
ASAdhitasari Suratman
Adhitasari Suratman
NANurul Hidayat Aprilita
Nurul Hidayat Aprilita
Silver nanoparticles having uniform size and shape, a diameter range of 10–50 nm, excellent stability, and high zeta potential are always desirable for many applications. The silver nanoparticles were synthesized by chemical reduction method using some reducing agents in a polyvinyl alcohol solution. This study aims at determining the effect of reducing agents on the chemical and physical properties of silver nanoparticles. Ascorbic acid, sodium borohydride, hydrazine, sodium citrate, and glucose were used as reducing agents. Surface Plasmon Resonance (SPR) absorbance, morphology, zeta potential, crystal system, and stability of the products were studied. The results showed that the chemical and physical properties of the colloidal Ag nanoparticles were dependent on the reducing agents. In general, the produced silver nanoparticles have an fcc crystal system with a unit cell of 4.0906–4.0992 Å. The SPR absorbance of the colloids has the peak in the range of 401–433 nm. We found that the colloid of silver nanoparticles prepared by using ascorbic acid has uniform spherical shape, the diameter of about 20 nm, and zeta potential of -10.4 mV. After being stored for one month, the SPR absorbance of the colloid decreased by only 5%. This type of colloidal Ag nanoparticles prepared by using ascorbic acid is expected to be used for chemical sensors, an antibacterial agent, and so on.