Vapors of volatile organic compounds such as benzene, toluene, and xylene (BTX) may cause health concerns. The sensitive detection of these compounds in air remains challenging. In this study, we reported on modification of the Quartz Crystal Microbalance (QCM) sensing chip using polyvinyl acetate (PVAc) film as active coating for the analysis of BTX vapors. The PVAc film was deposited on the QCM sensing chip surface by a spin coating technique. The morphology of the PVAc films was confirmed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The sensitivities of PVAc based QCM system for benzene, toluene, and xylene analyses were 0.018, 0.041, and 0.081 Hz/ppm, respectively. The high sensitivity of the proposed QCM system for analysis of BTX vapors is believed to be due to the effective interaction between the PVAc film and BTX molecules. The analyte vapor pressure appears to also affect the sensitivity. These data show that the prepared QCM sensor has a low time constant, good reproducibility, and excellent stability. It offers an alternative to the developed methods for detection of BTX and possibly other aromatic hydrocarbons in the air.
30 November 2025 in Journal of Energy, Material, and Instrumentation Technology
In this study, polyvinylpyrrolidone (PVP) (Mw ~40,000 g/mol) fibers were fabricated using distilled water and ethanol via an electrospinning approach. Morphological evaluations were carried out with a Scanning Electron Microscopy (SEM). Fiber diameters were analyzed with ImageJ. Solution Concentration of PVP with solvents adjusted to 50% (m/v), respectively. Then, the solution was electrospun with voltages of 8 and 12 kV. PVP/distilled water solution produced a relatively regular fiber network with enlarged junctions at 8 kV. However, it was ribbon-like, bead-like, and film-like in voltages of 12 kV. This structure was attributed to high surface tension and slow solvent evaporation. Another solution, PVP/ethanol, produced a relatively regular fiber network at 8 kV. The structure was different at 12 kV voltages. Globular and particle-like morphologies appear in these conditions. Fiber diameter was analyzed in the layers formed under 8 kV electrospinning conditions. The fiber diameter in PVP/distilled water was 1.05 ± 0.50 µm. Meanwhile, the fiber diameter in PVP/ethanol was 2.46 ± 0.64 µm. Although the fiber diameter was larger in PVP/ethanol, the resulting fiber was more continuous and more stable.
16 September 2025 in METHODIKA: Jurnal Teknik Informatika dan Sistem Informasi
Accurate blood cell classification is crucial for diagnosing Acute Myeloid Leukemia (AML) but limited medical data poses challenges for traditional machine learning models. This study presents a Few-Shot Learning (FSL) framework utilizing a Prototypical Network architecture with a ResNet-34 backbone to classify AML blood cell types from microscopic images. In this study, we utilize datasets consisting of 15 morphologically distinct cell classes. A 15-way, 5-shot, 5-query episodic setup was adopted to simulate data-scarce conditions. Evaluation via 5-fold cross-validation yielded strong performance, with an average accuracy of 97.76%, precision of 98.78%, recall of 96.55%, and F1-score of 97.76%. FSL training times were consistent (4.22–4.26 minutes per fold), and t-SNE along with confusion matrices confirmed the model’s ability to distinguish similar cell types. To validate the approach, its performance was compared with a conventional supervised CNN using the same ResNet-34 backbone. The FSL model outperformed the CNN across all metrics such as accuracy (98.32% vs. 77.25%), precision (98.55% vs. 76.87%), recall (98.31% vs. 78.66%), and F1-score (98.33% vs. 75.26%), while also requiring far less training time (~4.24 min/fold vs. ~420 min total). These results highlight the promise of FSL based methods for accurate, efficient, and scalable hematologic diagnostics in data limited settings.
Tuberculosis (TB) is a highly contagious illness and a major contributor to global mortality, with over 1.5 million deaths reported annually. TB is caused by Mycobacterium tuberculosis (Mtb), which is often difficult to diagnose in the early stages of infection. Existing diagnostic methods are limited by long processing times, high costs, and suboptimal sensitivity. Therefore, this study aimed to develop a Quartz Crystal Microbalance (QCM)-based biosensor employing polyvinyl chloride (PVC) nanofibers coated with graphene oxide (GO) for rapid detection of volatile TB biomarkers, particularly benzene. The sensing platform utilized a 10 MHz AT-cut silver electrode QCM coated with electrospun PVC nanofibers, followed by GO deposition via immersion. Scanning Electron Microscopy (SEM) showed uniform nanofibers with diameters increasing from 183 ± 54 nm to 348 ± 50 nm after GO coating, while FTIR confirmed the presence of GO functional groups. Sensor evaluation revealed a clear and concentration-dependent frequency shift, with a sensitivity of 1.88 Hz·L/mg, a strong linear correlation (R² = 0.99) across 1.18–23.68 mg/L, and a fast response time of 71 seconds. The limits of detection and quantification were determined to be 0.88 mg/L and 2.66 mg/L, respectively. Adsorption followed the Langmuir isotherm model, indicating monolayer uptake. These results demonstrate that the GO/PVC nanofiber-coated QCM offers a promising, low-cost, and sensitive approach for TB biomarker detection in breath analysis.
Penelitian ini bertujuan untuk menganalisis karakteristik kinematika linier tumit selama aktivitas berjalan, berlari, dan berlari cepat sebagai dasar untuk mengevaluasi biomekanika gerak manusia. Metode yang digunakan meliputi perekaman gerak menggunakan kamera dan analisis kecepatan vertikal tumit melalui perangkat lunak analisis gerak berbasis video. Data dikumpulkan dari grafik kecepatan-waktu vertikal dan pengukuran parameter gaya berjalan seperti panjang langkah, durasi fase berdiri dan berayun, frekuensi langkah, dan waktu siklus gaya berjalan. Hasil penelitian menunjukkan bahwa kecepatan vertikal tumit menunjukkan fluktuasi yang khas pada setiap jenis gerakan, dengan amplitudo dan durasi fase yang berubah seiring dengan peningkatan kecepatan gerak. Selama berlari cepat, kecepatan puncak yang sangat tinggi terjadi pada langkah awal, diikuti oleh pola fluktuasi yang lebih teratur. Temuan ini menunjukkan penyesuaian biomekanika yang kompleks untuk menjaga keseimbangan dan efisiensi gerak. Penelitian ini menyimpulkan bahwa analisis kecepatan vertikal tumit dapat berfungsi sebagai indikator yang berharga dalam memahami pola gerak dan mengidentifikasi potensi ketidakseimbangan atau gangguan gaya berjalan. Disarankan agar metode analisis gerak berbasis video diterapkan lebih luas dalam rehabilitasi, pelatihan atletik, dan pengembangan alat bantu mobilitas manusia.