Barbara Dymerska

Barbara Dymerska

Auto-generated profile, based on publicly available information

Barbara Dymerska

The Functional Imaging Laboratory, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, UK

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in NeuroImage
Verified
Journal Article
Open access
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
ESElisabeth Springer
Elisabeth Springer
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
SRSimon Daniel Robinson
Simon Daniel Robinson
The growing interest in ultra-high field MRI, with more than 35.000 MR examinations already performed at 7T, is related to improved clinical results with regard to morphological as well as functional and metabolic capabilities. Since the signal-to-noise ratio increases with the field strength of the MR scanner, the most evident application at 7T is to gain higher spatial resolution in the brain compared to 3T. Of specific clinical interest for neuro applications is the cerebral cortex at 7T, for the detection of changes in cortical structure, like the visualization of cortical microinfarcts and cortical plaques in Multiple Sclerosis. In imaging of the hippocampus, even subfields of the internal hippocampal anatomy and pathology may be visualized with excellent spatial resolution. Using Susceptibility Weighted Imaging, the plaque-vessel relationship and iron accumulations in Multiple Sclerosis can be visualized, which may provide a prognostic factor of disease. Vascular imaging is a highly promising field for 7T which is dealt with in a separate dedicated article in this special issue. The static and dynamic blood oxygenation level-dependent contrast also increases with the field strength, which significantly improves the accuracy of pre-surgical evaluation of vital brain areas before tumor removal. Improvement in acquisition and hardware technology have also resulted in an increasing number of MR spectroscopic imaging studies in patients at 7T. More recent parallel imaging and short-TR acquisition approaches have overcome the limitations of scan time and spatial resolution, thereby allowing imaging matrix sizes of up to 128×128. The benefits of these acquisition approaches for investigation of brain tumors and Multiple Sclerosis have been shown recently. Together, these possibilities demonstrate the feasibility and advantages of conducting routine diagnostic imaging and clinical research at 7T.

13 September 2016 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
SRSimon Daniel Robinson
Simon Daniel Robinson
KBKristian Bredies
Kristian Bredies
DKDiana Khabipova
Diana Khabipova
BDBarbara Dymerska
Barbara Dymerska
JMJosé P. Marques
José P. Marques
FSFerdinand Schweser
Ferdinand Schweser
Phase imaging benefits from strong susceptibility effects at very high field and the high signal‐to‐noise ratio (SNR) afforded by multi‐channel coils. Combining the information from coils is not trivial, however, as the phase that originates in local field effects (the source of interesting contrast) is modified by the inhomogeneous sensitivity of each coil. This has historically been addressed by referencing individual coil sensitivities to that of a volume coil, but alternative approaches are required for ultra‐high field systems in which no such coil is available. An additional challenge in phase imaging is that the phase that develops up to the echo time is “wrapped” into a range of 2π radians. Phase wraps need to be removed in order to reveal the underlying phase distribution of interest.Beginning with a coil combination using a homogeneous reference volume coil – the Roemer approach – which can be applied at 3 T and lower field strengths, we review alternative methods for combining single‐echo and multi‐echo phase images where no such reference coil is available. These are applied to high‐resolution data acquired at 7 T and their effectiveness assessed via an index of agreement between phase values over channels and the contrast‐to‐noise ratio in combined images. The virtual receiver coil and COMPOSER approaches were both found to be computationally efficient and effective.The main features of spatial and temporal phase unwrapping methods are reviewed, placing particular emphasis on recent developments in temporal phase unwrapping and Laplacian approaches. The features and performance of these are illustrated in application to simulated and high‐resolution in vivo data. Temporal unwrapping was the fastest of the methods tested and the Laplacian the most robust in images with low SNR. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

26 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BDBarbara Dymerska
Barbara Dymerska
KEKorbinian Eckstein
Korbinian Eckstein
BBBeata Bachrata
Beata Bachrata
BSBernard Siow
Bernard Siow
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
SRSimon Daniel Robinson
Simon Daniel Robinson
Purpose: To develop a rapid and accurate MRI phase‐unwrapping technique for challenging phase topographies encountered at high magnetic fields, around metal implants, or postoperative cavities, which is sufficiently fast to be applied to large‐group studies including Quantitative Susceptibility Mapping and functional MRI (with phase‐based distortion correction).Methods: The proposed path‐following phase‐unwrapping algorithm, ROMEO, estimates the coherence of the signal both in space—using MRI magnitude and phase information—and over time, assuming approximately linear temporal phase evolution. This information is combined to form a quality map that guides the unwrapping along a 3D path through the object using a computationally efficient minimum spanning tree algorithm. ROMEO was tested against the two most commonly used exact phase‐unwrapping methods, PRELUDE and BEST PATH, in simulated topographies and at several field strengths: in 3T and 7T in vivo human head images and 9.4T ex vivo rat head images.Results: ROMEO was more reliable than PRELUDE and BEST PATH, yielding unwrapping results with excellent temporal stability for multi‐echo or multi‐time‐point data. It does not require image masking and delivers results within seconds, even in large, highly wrapped multi‐echo data sets (eg, 9 seconds for a 7T head data set with 31 echoes and a 208 × 208 × 96 matrix size).Conclusion: Overall, ROMEO was both faster and more accurate than PRELUDE and BEST PATH, delivering exact results within seconds, which is well below typical image acquisition times, enabling potential on‐console application.

16 October 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
KEKorbinian Eckstein
Korbinian Eckstein
BDBarbara Dymerska
Barbara Dymerska
BBBeata Bachrata
Beata Bachrata
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
KPKarin Poljanc
Karin Poljanc
SRSimon Daniel Robinson
Simon Daniel Robinson

1 August 2016 in Investigative Radiology
Verified
Journal Article
Closed access
ESElisabeth Springer
Elisabeth Springer
BDBarbara Msc Dymerska
Barbara Msc Dymerska
PCPedro De Lima Cardoso
Pedro De Lima Cardoso
SRSimon Daniel Robinson
Simon Daniel Robinson
CWChristian Weisstanner
Christian Weisstanner
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
Objective: The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating disease, gliomas, cerebrovascular disease, and epilepsy, with comparable sequence protocols and acquisition times at 3 T and at 7 T. Materials and Methods: Ten healthy volunteers and 4 subgroups of 40 patients in total underwent comparable magnetic resonance protocols with standard diffusion-weighted imaging, 2D and 3D turbo spin echo, 2D and 3D gradient echo and susceptibility-weighted imaging of the brain (10 sequences) at 3 T and 7 T. The subgroups comprised patients with either lesional (n = 5) or nonlesional (n = 4) epilepsy, intracerebral tumors (n = 11), demyelinating disease (n = 11) (relapsing-remitting multiple sclerosis [MS, n = 9], secondary progressive MS [n = 1], demyelinating disease not further specified [n = 1]), or chronic cerebrovascular disorders [n = 9]). For quantitative analysis, SNR and CNR were determined. For a semiquantitative assessment of the diagnostic confidence, a 10-point scale diagnostic confidence score (DCS) was applied. Two experienced radiologists with additional qualification in neuroradiology independently assessed, blinded to the field strength, 3 pathology-specific imaging criteria in each of the 4 disease groups and rated their diagnostic confidence. The overall image quality was semiquantitatively assessed using a 4-point scale taking into account whether diagnostic decision making was hampered by artifacts or not. Results: Without correction for spatial resolution, SNR was higher at 3 T except in the T2 SPACE 3D, DWI single shot, and DIR SPACE 3D sequences. The SNR corrected by the ratio of 3 T/7 T voxel sizes was higher at 7 T than at 3 T in 10 of 11 sequences (all except for T1 MP2RAGE 3D). In CNR, there was a wide variation between sequences and patient cohorts, but average CNR values were broadly similar at 3 T and 7 T. DCS values for all 4 pathologic entities were higher at 7 T than at 3 T. The DCS was significantly higher at 7 T for diagnosis and exclusion of cortical lesions in vascular disease. A tendency to higher DCS at 7 T for cortical lesions in MS was observed, and for the depiction of a central vein and iron deposits within MS lesions. Despite motion artifacts, DCS values were higher at 7 T for the diagnosis and exclusion of hippocampal sclerosis in mesial temporal lobe epilepsy (improved detection of the hippocampal subunits). Interrater agreement was 69.7% at 3 T and 93.3% at 7 T. There was no significant difference in the overall image quality score between 3 T and 7 T taking into account whether diagnostic decision making was hampered by artifacts or not. Conclusions: Ultra–high-field magnetic resonance imaging at 7 T compared with 3 T yielded an improved diagnostic confidence in the most frequently encountered neurologic disorders. Higher spatial resolution and contrast were identified as the main contributory factors.

1 March 2018 in NeuroImage
Verified
Journal Article
Open access
BDBarbara Dymerska
Barbara Dymerska
BPBenedikt A Poser
Benedikt A Poser
MBMarkus Barth
Markus Barth
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
SRSimon D. Robinson
Simon D. Robinson
We propose a method to calculate field maps from the phase of each EPI in an fMRI time series. These field maps can be used to correct the corresponding magnitude images for distortion caused by inhomogeneity in the static magnetic field. In contrast to conventional static distortion correction, in which one 'snapshot' field map is applied to all subsequent fMRI time points, our method also captures dynamic changes to B0 which arise due to motion and respiration. The approach is based on the assumption that the non-B0-related contribution to the phase measured by each radio-frequency coil, which is dominated by the coil sensitivity, is stable over time and can therefore be removed to yield a field map from EPI. Our solution addresses imaging with multi-channel coils at ultra-high field (7T), where phase offsets vary rapidly in space, phase processing is non-trivial and distortions are comparatively large. We propose using dual-echo gradient echo reference scan for the phase offset calculation, which yields estimates with high signal-to-noise ratio. An extrapolation method is proposed which yields reliable estimates for phase offsets even where motion is large and a tailored phase unwrapping procedure for EPI is suggested which gives robust results in regions with disconnected tissue or strong signal decay. Phase offsets are shown to be stable during long measurements (40min) and for large head motions. The dynamic distortion correction proposed here is found to work accurately in the presence of large motion (up to 8.1°), whereas a conventional method based on single field map fails to correct or even introduces distortions (up to 11.2mm). Finally, we show that dynamic unwarping increases the temporal stability of EPI in the presence of motion. Our approach can be applied to any EPI measurements without the need for sequence modification.