YANG TAO

Mr. YANG TAO

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
YZYi Zhang
Yi Zhang
YTYANG TAO
YANG TAO
MYMiao Yiru
Miao Yiru
Compared to the voltage source inverter, the current source inverter (CSI) can boost voltage and improve filtering performance. However, the DC side of CSI is not a real current source, and the DC input current comprises a DC power supply and an inductor. In the switching process, the DC-link inductor is charged or discharged and is in an uncontrollable state. This paper proposes a novel CSI topology containing five switching tubes and a modulation strategy based on the hysteresis control strategy of the DC-link current. Due to the conduction and switching loss being positive to the DC-link current, the calculation method for the least reference value of the DC-link current is derived to meet power requirements. By constructing a virtual axis, we then present the control strategy of the output voltage in a two-phase rotating reference frame. Finally, we carry out the simulation and experiment are to validate the proposed topology, modulation, and control strategy.

21 May 2024 in IET Power Electronics
Verified
Journal Article
Open access
YTYANG TAO
YANG TAO
LCLan Chen
Lan Chen
YMYiru Miao
Yiru Miao
This paper proposes a predictive power control strategy for the three‐phase, six‐switch Vienna rectifier without grid voltage sensors to reduce the hardware cost and complexity of a high‐power PWM rectifier system. Firstly, an algorithm for calculating the AC‐side voltage in the αβ coordinate system is derived according to the operating principle of the Vienna rectifier, and a voltage observer is constructed by combining a second‐order low‐pass filter to estimate the grid voltage. Secondly, a soft start method is designed to solve the problem that the rectifier is prone to inrush current when it is started. Furthermore, the control method of grid voltage sensorless is combined with predictive power control with good dynamic characteristics and simple parameter settings to form the control strategy proposed in this paper. Finally, simulation analysis and experimental verification are carried out on the proposed control strategy. Simulation and experimental results show that the grid voltage estimation has high accuracy, a good surge current suppression effect, unit power factor operation, low input current harmonic content, and good dynamic and steady‐state performance. Therefore, the correctness and effectiveness of the strategy proposed in this paper are verified.

2 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
YTYANG TAO
YANG TAO
YLYong Liao
Yong Liao
Since the zero initial conditions of the boost converter are far from the target equilibrium point, the overshoot of the input current and the output voltage will cause energy loss during the start-up process when the converter adopts the commonly used small-signal model design control method. This paper presents a sliding mode control strategy that combines two switching surfaces. One switching surface based on the large-signal model is employed for the start-up to minimize inrush current and voltage overshoot. The stability of this strategy is verified by Lyapunov theory and simulation. Once the converter reaches the steady-state, the other switching surface with PI compensation of voltage error is employed to improve the robustness. The latter switching surface, which is adopted to regulate the voltage, can not only suppress the perturbation of input voltage and load, but also achieve a better dynamic process and a zero steady-state error. Furthermore, the discrete sliding mode controller is implemented by digital signal processor (DSP). Finally, the results of simulation, experiment and theoretical analysis are consistent.

15 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
YTYANG TAO
YANG TAO
XCXiaoqing Chen
Xiaoqing Chen
YLYixin Liu
Yixin Liu
LLLingyan Luo
Lingyan Luo
YWYiming Wang
Yiming Wang
SBShibo Bin
Shibo Bin
This paper presents a strategy to mitigate electromagnetic noise in induction motors for electric vehicles by optimizing the rotor slot count and skewing distance. Initially, the magnetomotive forces (MMF) of the stator and rotor windings, air-gap permeance, and the predominant radial electromagnetic force waves in the air-gap magnetic field were analytically determined and compiled. A finite element model of the original 36/42 straight-slot configuration was established for simulation validation. Subsequently, a preliminary optimization scheme for rotor slot number was proposed. A systematic analysis was conducted of the circumferential distribution of radial force waves and their harmonic components in both temporal and spatial orders by comparing electromagnetic vibration characteristics across different rotor slot configurations (42 versus 53 slots) using two-dimensional Fourier decomposition. Furthermore, building upon the mechanism of tooth harmonic suppression via rotor skewing, an advanced optimization strategy for skewing distance was developed. Comparative analysis of harmonic content in air-gap flux density under three configurations (straight slot, 1.0× skewing, and 1.2× skewing) revealed the optimal solution. Experimental vibration tests demonstrated significant improvements: the optimized 53-slot rotor with 1.2× skewing reduced vibration amplitudes by 5 dB·Hz at the 2nd-order natural frequency, 5 dB·Hz at the 3rd-order natural frequency, and 18 dB·Hz at the 3rd-order resonance peak compared to the original 42-slot straight-slot design. These results confirm that coordinated optimization of rotor slot number and skewing distance effectively mitigates electromagnetic vibration and noise in traction motors.

24 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
QXQiuyue Xie
Qiuyue Xie
XQXu Qiwei
Xu Qiwei
YTYANG TAO
YANG TAO
YTYuxiaoying Tu
Yuxiaoying Tu
In order to improve the current dynamic performance of induction motor (IM) drive systems, an internal model current decoupling control strategy is proposed to suppress the stator’s internal coupling effect. First, the IM mathematical model in the complex frequency domain is established, and the expressions of the coupling terms are derived. Then, according to the zero-pole distribution diagram and Bode plots, the design details for the structure and parameters of the internal model controller are presented in a continuous domain, and the impact of stator inductance mismatch on decoupling performance is analyzed. In addition to considering sampling and control delays, the IM mathematical model is established in the discrete domain, and the principle of the controller parameter is presented. Finally, the experimental results prove that the proposed internal model current decoupling control strategy can effectively improve the dynamic performance of IMs. Compared with the traditional feedforward current decoupling control strategy, the proposed method has superior decoupling performance under the operating conditions of low switching frequency. At the same time, a better steady-state performance is obtained by the proposed internal model control strategy.

10 June 2024 in IET Electric Power Applications
Verified
Journal Article
Open access
YTYANG TAO
YANG TAO
YWYiming Wang
Yiming Wang
YMYiru Miao
Yiru Miao
QXQiwei Xu
Qiwei Xu
QGQiang Guo
Qiang Guo
In the cost function of model predictive torque control (MPTC) of permanent magnet synchronous motor (PMSM), torque and flux linkage have different dimensions, and the weighting factor needs to be properly adjusted to optimise the control performance. Therefore, based on the discrete mathematical model of PMSM, the torque predictive error and flux predictive error expressions are mapped to the two‐phase static coordinate system, which is equivalent to the distance expressions from the endpoint of the voltage vector to the straight line and to the circle respectively. Because they have the same dimension, they can be directly superimposed to form the cost function proposed, which eliminates the selection process of the weighting factor. Then, the candidate voltage vector is substituted into the cost function in turn, and the optimal voltage vector with the minimum cost function is selected as the voltage input of the next control cycle. Finally, the simulation model and an experimental platform are established to compare the steady‐state and dynamic performance of the geometric solution‐based weighting factor determined method proposed with other MPTC methods.