Yifan Hu

Yifan Hu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Electronics
Verified
Journal Article
Open access
PDF file
YHYifan Hu
Yifan Hu
PXPeng Xun
Peng Xun
WKWenjie Kang
Wenjie Kang
PZPeidong Zhu
Peidong Zhu
YXYinqiao Xiong
Yinqiao Xiong
SWShi Weiheng
Shi Weiheng
The ever-expanding power system is developed into an interconnected pattern of power grids. Zone partitioning is an essential technique for the operation and management of such an interconnected power system. Owing to the transmission capacity limitation, transmission congestion may occur with a regional influence on power system. If transmission congestion is considered when the system is decomposed into several regions, the power consumption structure can be optimized and power system planning can be more reasonable. At the same time, power resources can be properly allocated and system safety can be improved. In this paper, we propose a power system zone partitioning method where the potential congested branches are identified and the spectral clustering algorithm is improved. We transform the zone partitioning problem into a graph segmentation problem by constructing an undirected weighted graph of power system where the similarities between buses are measured by the power transfer distribution factor (PTDF) corresponding to the potential congested branches. Zone partitioning results show that the locational marginal price (LMP) in the same zone is similar, which can represent regional price signals and provide regional auxiliary decisions.

16 April 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
YZyufei zhu
yufei zhu
ZXZC XING
ZC XING
ZLZerun Li
Zerun Li
Yang ZhangYang Zhang
Yang Zhang
YHYifan Hu
Yifan Hu
This paper presents a novel parallel quasi-cyclic low-density parity-check (QC-LDPC) encoding algorithm with low complexity, which is compatible with the 5th generation (5G) new radio (NR). Basing on the algorithm, we propose a high area-efficient parallel encoder with compatible architecture. The proposed encoder has the advantages of parallel encoding and pipelined operations. Furthermore, it is designed as a configurable encoding structure, which is fully compatible with different base graphs of 5G LDPC. Thus, the encoder architecture has flexible adaptability for various 5G LDPC codes. The proposed encoder was synthesized in a 65 nm CMOS technology. According to the encoder architecture, we implemented nine encoders for distributed lifting sizes of two base graphs. The eperimental results show that the encoder has high performance and significant area-efficiency, which is better than related prior art. This work includes a whole set of encoding algorithm and the compatible encoders, which are fully compatible with different base graphs of 5G LDPC codes. Therefore, it has more flexible adaptability for various 5G application scenarios.

24 August 2023 in Electric Power Systems Research
Verified
Journal Article
Closed access
YHYifan Hu
Yifan Hu
GZGuomin Zhang
Guomin Zhang
XWXiulei Wang
Xiulei Wang
CXChangyou Xing
Changyou Xing
BXBo Xu
Bo Xu
WDWei Ding
Wei Ding

2 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PZPeidong Zhu
Peidong Zhu
PXPeng Xun
Peng Xun
YHYifan Hu
Yifan Hu
YXYinqiao Xiong
Yinqiao Xiong
A large-scale Cyber-Physical System (CPS) such as a smart grid usually provides service to a vast number of users as a public utility. Security is one of the most vital aspects in such critical infrastructures. The existing CPS security usually considers the attack from the information domain to the physical domain, such as injecting false data to damage sensing. Social Collective Attack on CPS (SCAC) is proposed as a new kind of attack that intrudes into the social domain and manipulates the collective behavior of social users to disrupt the physical subsystem. To provide a systematic description framework for such threats, we extend MITRE ATT&CK, the most used cyber adversary behavior modeling framework, to cover social, cyber, and physical domains. We discuss how the disinformation may be constructed and eventually leads to physical system malfunction through the social-cyber-physical interfaces, and we analyze how the adversaries launch disinformation attacks to better manipulate collective behavior. Finally, simulation analysis of SCAC in a smart grid is provided to demonstrate the possibility of such an attack.

26 October 2021 in Security and Communication Networks
Verified
Journal Article
Open access
PDF file
YHYifan Hu
Yifan Hu
PXPeng Xun
Peng Xun
PZPeidong Zhu
Peidong Zhu
WKWenjie Kang
Wenjie Kang
YXYinqiao Xiong
Yinqiao Xiong
CHChenxi Hu
Chenxi Hu
Static characteristics of supervisory control and data acquisition (SCADA) system are often exploited to perform malicious activities on smart grids. Most of the time, the success of cyberattacks begins with the profiling of the target system and follows by the analysis of the limited resources. To alleviate the asymmetry between attack and defense, network-based moving target defense (MTD) techniques have been applied in the network system to defend against cyberattacks by constructing a dynamic attack surface to the adversary. In this paper, we propose a novel MTD technique based on adaptive forwarding path migration (AFPM) that focuses on improving the defense capability and optimizing the network performance of path mutation. Considering the transient problems present in path mutation caused by the dynamic switching of the forwarding path, we formalize the mutation constraints based on the satisfiability modulo theory (SMT) to select the mutation path. Considering the limited defense capability of path mutation owing to the traditional mutation selection mechanism, we design the mutation path generation algorithm based on the network security capacity matrix to obtain an optimal combination of mutation path and mutation period. Finally, we compare and analyze various cyber defense techniques used in the SCADA network and demonstrate experimentally that our MTD technique can prevent more than 92% of passive monitoring under specified conditions while ensuring the quality of service (QoS) to be almost the same as the static network.

1 January 2026 in IEEE Transactions on Audio, Speech and Language Processing
Verified
Journal Article
Closed access
CHChenxi Hu
Chenxi Hu
TWTao Wu
Tao Wu
YHYifan Hu
Yifan Hu
YHYangyi Hu
Yangyi Hu
NZNing Zhu
Ning Zhu