21 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Relevant to mobile health, the design of a portable electrocardiograph (ECG) device using AD823X microchips as the analog front-end is presented. Starting with the evaluation board of the chip, open-source hardware and software components were integrated into a breadboard prototype. This required modifying the microchip with the breadboard-friendly Arduino Nano board in addition to a data logger and a Bluetooth breakout board. The digitized ECG signal can be transmitted by serial cable, via Bluetooth to a PC, or to an Android smartphone system for visualization. The data logging shield provides gigabytes of storage, as the signal is recorded to a microSD card adapter. A menu incorporates the device’s several operating modes. Simulation and testing assessed the system stability and performance parameters in terms of not losing any sample data throughout the length of the recording and finding the maximum sampling frequency; and validation determined and resolved problems that arose in open-source development. Ultimately, a custom printed circuit board was produced requiring advanced manufacturing options of 2.5 mils trace widths for the small package components. The fabricated device did not degrade the AD823X noise performance, and an ECG waveform with negligible distortion was obtained. The maximum number of samples/second was 2380 Hz in serial cable transmission, whereas in microSD recording mode, a continuous ECG signal for up to 36 h at 500 Hz was verified. A low-cost, high-quality portable ECG for long-term monitoring prototype that reasonably complies with electrical safety regulations and medical equipment design was realized.

Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
MGMaria Luisa Gonzalez
Maria Luisa Gonzalez
Interoperability is defined as the ability of a system or device to communicate between different technologies and software applications. This allows the exchange and use of data in an efficient, precise, and robust way. The present article gives researchers and healthcare information systems developers a qualitative and quantitative synthesis of the state of knowledge related to data formats and data standards proposed for mHealth devices interoperability in healthcare information systems that retrieve and store ECG data. We carry out a scoping review to answer to following questions: (1) What digital data formats or data standards have been proposed for the interoperability of electrocardiograph data between traditional healthcare information systems and mobile healthcare information systems? (2) What are the advantages and disadvantages of these data formats or data standards? The scoping review was conducted in four databases in accordance with the JBI methodology for scoping reviews, and in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). A total of 4018 studies were identified of which 30 studies met the inclusion criteria. Based on our findings, we identify four standards and nine formats for capturing and storing streaming ECG data in mobile health applications. The standards used were HL7, SCP-ECG, x73-PHD, and PDF/A. Formats include CSV, PDF-ECG, and seven XML-based formats. These are ECG-XML, HL7-XML, mPCG-XML, mECGML, JSON, SaECG, and CDA R2.

10 May 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
MCManuel M. Casas
Manuel M. Casas
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
FGFelix F. Gonzalez-Navarro
Felix F. Gonzalez-Navarro
JCJose A. Cardenas-Haro
Jose A. Cardenas-Haro
MRMarco A. Reyna
Marco A. Reyna
According to the American Heart Association, in its latest commission about Ventricular Arrhythmias and Sudden Death 2006, the epidemiology of the ventricular arrhythmias ranges from a series of risk descriptors and clinical markers that go from ventricular premature complexes and nonsustained ventricular tachycardia to sudden cardiac death due to ventricular tachycardia in patients with or without clinical history. The premature ventricular complexes (PVCs) are known to be associated with malignant ventricular arrhythmias and sudden cardiac death (SCD) cases. Detecting this kind of arrhythmia has been crucial in clinical applications. The electrocardiogram (ECG) is a clinical test used to measure the heart electrical activity for inferences and diagnosis. Analyzing large ECG traces from several thousands of beats has brought the necessity to develop mathematical models that can automatically make assumptions about the heart condition. In this work, 80 different features from 108,653 ECG classified beats of the gold-standard MIT-BIH database were extracted in order to classify the Normal, PVC, and other kind of ECG beats. Three well-known Bayesian classification algorithms were trained and tested using these extracted features. Experimental results show that the F1 scores for each class were above 0.95, giving almost the perfect value for the PVC class. This gave us a promising path in the development of automated mechanisms for the detection of PVC complexes.

14 November 2019 in Proceedings
Verified
Conference Paper
Open access
PDF file
Miguel Bravo-ZanogueraMiguel Bravo-Zanoguera
Miguel Bravo-Zanoguera
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
This paper presents the design of a portable electrocardiograph (ECG) device using the AD8232 microchip as the analog front-end (AFE). Starting with the manufacturer’s evaluation board of the AFE chip for testing circuit configurations, open-source hardware and software components were integrated into a breadboard prototype. Ultimately, a custom printed circuit board (PCB) was produced. The prototype required to accommodate the microchip on a SMD-to-DIP adapter for testing with the breadboard-friendly Arduino microcontroller alongside a data logger and a Bluetooth breakout board. The analog ECG signal from the AFE output was digitized using one channel of the 10-bit analog-to-digital Converter (ADC) of the ATmega328 microcontroller contained in the Arduino Nano board. The digitized ECG signal can be transmitted not only by serial cable using the Arduino functions, but also via Bluetooth to a PC or to an Android smartphone system when the HC-06 shield is used. The data logging shield provides gigabytes of storage, and the signal is recorded to a micro SD card adapter along with the date and time stamp data of the sample capture (real-time clock provided). In addition to hardware and software development, a simulation was used in the analog circuit design with SPICE Multisim software and the related macromodel library to assess system stability. Besides the analog filters in the AFE stage, digital filtering by means of simple difference equations was investigated. A menu was incorporated to choose from the several modes of operation of the device. The ECG test signals were obtained from a patient simulator (SimCube) and real patients. A portable ECG system for monitoring applications that complies with electrical safety regulations and medical equipment design was realized.

24 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
SESharon Ezrre
Sharon Ezrre
MRMarco Antonio Reyna
Marco Antonio Reyna
RARosa Anguiano
Rosa Anguiano
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
HMHeriberto Marquez
Heriberto Marquez
Lab-on-a-Chip (LoC) devices are described as versatile, fast, accurate, and low-cost platforms for the handling, detection, characterization, and analysis of a wide range of suspended particles in water-based environments. However, for gas-based applications, particularly in atmospheric aerosols science, LoC platforms are rarely developed. This review summarizes emerging LoC devices for the classification, measurement, and identification of airborne particles, especially those known as Particulate Matter (PM), which are linked to increased morbidity and mortality levels from cardiovascular and respiratory diseases. For these devices, their operating principles and performance parameters are introduced and compared while highlighting their advantages and disadvantages. Discussing the current applications will allow us to identify challenges and determine future directions for developing more robust LoC devices to monitor and analyze airborne PM.

23 April 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
AVAlvaro Osornio Vargas
Alvaro Osornio Vargas
Air pollution is caused by the presence of polluting elements. Ozone (O3), carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), sulfur dioxide (SO2), and particulate matter (PM) are the most controlled gasses because they can be released into the atmosphere naturally or as a result of human activity, which affects air quality and causes disease and premature death in exposed people. Depending on the substance being measured, ambient air monitors have different types of air quality sensors. In recent years, there has been a growing interest in designing drones as mobile sensors for monitoring air pollution. Therefore, the objective of this paper is to provide a comprehensive patent review to gain insight into the proprietary technologies currently used in drones used to monitor outdoor air pollution. Patent searches were conducted using three different patent search engines: Google Patents, WIPO’s Patentscope, and the United States Patent and Trademark Office (USPTO). The analysis of each patent consists of extracting data that supply information regarding the type of drone, sensor, or equipment for measuring PM, the lack or presence of a cyclone separator, and the ability to process the turbulence generated by the drone’s propellers. A total of 1473 patent documents were retrieved using the search engine. However, only 13 met the inclusion criteria, including patent documents reporting drone designs for outdoor air pollution monitoring. Therefore, was found that most patents fall under class G01N (measurement; testing) according to the International Patents Classification, where the most common sensors and devices are infrared or visible light cameras, cleaning devices, and GPS tracking devices. The most common tasks performed by drones are air pollution monitoring, assessment, and control. These categories cover different aspects of the air pollution management cycle and are essential to effectively address this environmental problem.