Ning Ji

Ning Ji

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2019 in IEEE Access
Verified
Journal Article
Open access
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
MAMojisola Grace Asogbon
Mojisola Grace Asogbon
YGYanjuan Geng
Yanjuan Geng
AAAli H. Al-Timemy
Ali H. Al-Timemy
SPSandeep Pirbhulal
Sandeep Pirbhulal
GLGuanglin Li
Guanglin Li
Upper-limb amputation imposes significant burden on amputees thereby restricting them from fully exploring their environments during activities of daily living. The use of intelligent learning algorithm for electromyogram-pattern recognition (EMG-PR)-based control in upper-limb prostheses is considered as an important clinical option. Though the existing EMG-PR prostheses could discriminate multiple degrees of freedom (DOF) limb movements, their transition to clinically viable option is still being challenged by some confounding factors. Toward realizing a clinically viable multiple DOF prostheses, this paper first explored the principles and dynamics of the existing intelligently driven EMG-PR-based prostheses control scheme. Then, investigations on core issues including variation in muscle contraction force, electrode shift, and subject mobility affecting the existing EMG-PR prosthetic control scheme were reported. For instance, variation in muscle contraction force and subject mobility led to degradation in the performance of the EMG-PR controlled prostheses with approximately 17.00% and 8.98% error values, respectively, which are still challenging issues among others. Thus, this paper reports core issues and best practices with respect to intelligent EMG-PR controlled prosthesis, the major challenges in implementing adaptively robust control scheme and provides future research directions that may result in the clinical realization of intuitively dexterous multiple DOF EMG-PR-based prostheses in the near future.

8 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NJNing Ji
Ning Ji
HZHui Zhou
Hui Zhou
KGKaifeng Guo
Kaifeng Guo
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
ZHZhen Huang
Zhen Huang
GLGuanglin Li
Guanglin Li
Gait event detection is a crucial step towards the effective assessment and rehabilitation of motor dysfunctions. Recently, the continuous wavelet transform (CWT) based methods have been increasingly proposed for gait event detection due to their robustness. However, few investigations on determining the appropriate mother wavelet with proper selection criteria have been performed, especially for hemiplegic patients. In this study, the performances of commonly used mother wavelets in detecting gait events were systematically investigated. The acceleration signals from the tibialis anterior muscle of both healthy and hemiplegic subjects were recorded during ground walking and the two core gait events of heel strike (HS) and toe off (TO) were detected from the signal recordings by a CWT algorithm with different mother wavelets. Our results showed that the overall performance of the CWT algorithm in detecting the two gait events was significantly different when using various mother wavelets. By using different wavelet selection criteria, we also found that the accuracy criteria based on time-error minimization and F1-score maximization could provide the appropriate mother wavelet for gait event detection. The findings from this study will provide an insight on the selection of an appropriate mother wavelet for gait event detection and facilitate the development of adequate rehabilitation aids.

12 November 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
NJNing Ji
Ning Ji
WLWan-Hua Lin
Wan-Hua Lin
FCFei Chen
Fei Chen
LXLisheng Xu
Lisheng Xu
JHJianping Huang
Jianping Huang
GLGuanglin Li
Guanglin Li
Objective: For hypertensive individuals, their blood pressure (BP) is often managed by taking medications. However, antihypertensive drugs might cause adverse effects such as congestive heart failure and are ineffective in significant numbers of hypertensive population. As alternative method for hypertension management, non-drug devices-based neuromodulation approaches such as functional electrical stimulation (FES) have been proposed. FES approach requires the implantation of a stimulator into body. One recently emerging technique, called low-intensity focused ultrasound stimulation (LIFUS), has been proposed to non-invasively modulate neural activities. In this pilot study, the feasibility of adopting LIFUS neuromodulation for BP regulation was investigated using animal models. Methods: A LIFUS system was developed for BP modulation in rabbits. For each rabbit, the LIFUS with different acoustic intensities was used to stimulate its exposed left vagus nerve, and the BP waveform was synchronously recorded in its right common carotid artery. The effects of the different LIFUS intensities on systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and heart rate (HR) were extensively examined from the BP recordings. Results: The results demonstrated that the proposed LIFUS method could successfully induce changes in SBP, DBP, MAP, and HR values. When increasing acoustic intensities, the values of SBP, DBP, and MAP would decrease more substantially. Conclusion: The findings of this study suggested that BP could be modulated through the LIFUS, which might provide a new way for non-invasive and non-drug management of hypertension.

1 December 2022 in Journal of Neural Engineering
Verified
Journal Article
Open access
NJNing Ji
Ning Ji
YLYuanheng Li
Yuanheng Li
JWJingjing Wei
Jingjing Wei
FCFei Chen
Fei Chen
LXLisheng Xu
Lisheng Xu
WLWan-Hua Lin
Wan-Hua Lin
Objective. Our previous study has shown that low-intensity focused ultrasound stimulation (FUS) of the vagus nerve could modulate blood pressure (BP), but its underlying mechanisms remain unclear. We hypothesized that low-intensity FUS of the vagus nerve would regulate autonomic function and thus BP. Approach. 17 anesthetized spontaneously hypertensive rats were treated with low-intensity FUS of the left vagus nerve for 15 min each trial. Continuous BP, heart rate, respiration rate (RR), and core body temperature were simultaneously recorded to evaluate the effects on BP and other physiological parameters. Heart rate variability (HRV), systolic BP variability, and baroreflex sensitivity were computed to evaluate the autonomic modulation function. A Control-sham group without stimulation and another Control-FUS group with non-target stimulation were also examined to exclude the influence of potential confounding factors on autonomic modulation. Main results. A prolonged significant decrease in BP, pulse pressure, RR, the normalized low-frequency power of HRV, and the low-to-high frequency power ratio of HRV were found after the low-intensity FUS of the left vagus nerve in comparison with the baseline and those of the control groups, demonstrating that activities of the sympathetic nervous system were inhibited. The prolonged significant increase of the normalized high-frequency power of HRV suggested the activation of parasympathetic activity. Significance. Low-intensity FUS of the left vagus nerve effectively improved the autonomic function by activating parasympathetic efferent and inhibiting sympathetic efferent, which contributes to BP reduction. The findings shed light on the hypotensive mechanism underlying FUS.

25 September 2012 in Journal of Obstetrics and Gynaecology Research
Verified
Journal Article
Closed access
PDF file
NJNing Ji
Ning Ji
YZYou Zhou
You Zhou
YZYing Zhang
Ying Zhang
DHDian He
Dian He
CPCHENG PANG
CHENG PANG
YCYimin Cheng
Yimin Cheng

7 April 2026 in Physiological Measurement
Verified
Journal Article
Closed access
XLXiangni Lin
Xiangni Lin
GLGengxing Liu
Gengxing Liu
LWLin Wang
Lin Wang
XZXiaomeng Zhou
Xiaomeng Zhou
XDXinping Deng
Xinping Deng
WLWan-Hua Lin
Wan-Hua Lin
Objective: Heart rate variability (HRV) is widely used to assess autonomic function, but the minimum data length required for reliable ultra-short-term frequency-domain analysis remains without consensus. This study aimed to (1) identify factors determining the minimum required length and (2) determine minimum length for reliable estimation. Methods: Simulated relatively stationary inter-beat intervals (IBIs) were used to examine spectral factors influencing minimum data length. Relatively stationary IBIs from 20-min resting electrocardiogram (ECG) recordings in eight healthy subjects were analyzed to determine practical requirements. High frequency (HF) and low frequency (LF) estimates were compared against 5-min references, and very low frequency (VLF) against 20-min references, using limits of agreement (LoA) and intraclass correlation coefficient (ICC). Results: Both signal properties (spectral distribution proximity to defined band edges) and spectral analysis parameters (window and segment length) are critical factors determining the minimum required length. Data lengths of ~60 s, 100s, and 1000 s provided coarse estimates for HF, LF, and VLF, respectively, with ICC > 0.9. More reliable estimates were achieved at ~90 s, 250 s, and 1080 s, where the LoA remained within ±20%. Even stricter reliability was obtained at ~200 s, 290 s, and 1180 s, where the LoA further narrowed to within ±10%. Although LF achieved ICC >0.90 at ~100 s, the LoA remained wide (>±50%), reliable LF estimation required ≥220 s, where both absolute values and ICC stabilized. Conclusion: These findings offer methodological insights into the selection of recording durations and parameters for ultra-short-term frequency-domain HRV analysis in clinical, wearable, and research applications.