Hyun Deok Kim

Prof. Hyun Deok Kim

Kyungpook National University, School of Electronics Engineering
+1

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
SASheikh Faisal Ahmad
Sheikh Faisal Ahmad
YKYOUNG CHEOL KIM
YOUNG CHEOL KIM
ICIck Chang Choi
Ick Chang Choi
HKHyun Deok Kim
Hyun Deok Kim
The radio frequency (RF) coil is one of the key components of the magnetic resonance imaging (MRI) system. It has a significant impact on the performance of the nuclear magnetic resonance (NMR) detection. Among numerous practical designs of RF coils for NMR imaging, the birdcage RF coil is the most popular choice from low field to ultra-high field MRI systems. In the transmission mode, it can establish a strong and homogeneous transverse magnetic field B1 for any element at its Larmor frequency. Similarly, in the reception mode, it exhibits extremely high sensitivity for the detection of even faint NMR signals from the volume of interest. Despite the sophisticated 3D structure of the birdcage coil, the developments in the design, analysis, and implementation technologies during the past decade have rendered the development of the birdcage coils quite reasonable. This article provides a detailed review of the recent progress in the birdcage RF coil technology for the MRI system.

7 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKTae-Gu Kim
Tae-Gu Kim
BYByoung-Ju Yun
Byoung-Ju Yun
TKTae-Hun Kim
Tae-Hun Kim
JLJae-Young Lee
Jae-Young Lee
KPKil-houm Park
Kil-houm Park
HKHyun Deok Kim
Hyun Deok Kim
In this study, we have proposed an algorithm that solves the problems which occur during the recognition of a vehicle license plate through closed-circuit television (CCTV) by using a deep learning model trained with a general database. The deep learning model which is commonly used suffers with a disadvantage of low recognition rate in the tilted and low-resolution images, as it is trained with images acquired from the front of the license plate. Furthermore, the vehicle images acquired by using CCTV have issues such as limitation of resolution and perspective distortion. Such factors make it difficult to apply the commonly used deep learning model. To improve the recognition rate, an algorithm which is a combination of the super-resolution generative adversarial network (SRGAN) model, and the perspective distortion correction algorithm is proposed in this paper. The accuracy of the proposed algorithm was verified with a character recognition algorithm YOLO v2, and the recognition rate of the vehicle license plate image was improved 8.8% from the original images.

7 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoonseok Kim
Yoonseok Kim
Gu-In JungGu-In Jung
Gu-In Jung
DJDeokmin Jeon
Deokmin Jeon
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
DSDaewoon Seong
Daewoon Seong
JKJeehyun Kim
Jeehyun Kim
The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.

26 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YKYOUNG CHEOL KIM
YOUNG CHEOL KIM
HKHyun Deok Kim
Hyun Deok Kim
BYByoung-Ju Yun
Byoung-Ju Yun
SASheikh Faisal Ahmad
Sheikh Faisal Ahmad
A novel analytical solution for the designing of the birdcage RF coil has been demonstrated in this paper. A new concept of dominant resonance path has been introduced in this paper which is used to identify the specific closed current loop in the birdcage RF coil which is responsible for the dominant resonance frequency mode. This concept is used to determine the precise numerical values of the lumped capacitance deployed in the legs and/or end-rings of the birdcage RF coil for its proper operation at the desired resonance frequency. The analytical solution presented in this paper has been established by performing the two-port network based equivalent circuit modeling of the birdcage RF coil. The proposed analytical solution uses T-matrix theory and develops a relationship between the input impedance of the birdcage coil and the impedances of its leg and end-ring segments. The proposed analytical solution provides the information about the resonance frequency spectrum of the birdcage RF coil and solves the issue of its interfacing with external circuits without affecting its resonance characteristics. Based upon the proposed analysis and designing strategy presented in this paper, the low pass, high pass and band pass configurations of the birdcage RF coil were successfully implemented with FPCB (Flexible Printed Circuit board) technique for small volume NMR imaging applications at 1.5 T and 3.0 T MRI system. The results obtained for the implemented birdcage coils using the proposed analysis and designing technique are in closed agreement with already established methods.

30 April 2021 in Journal of Welding and Joining
Verified
Journal Article
Open access
PDF file
SSSeongSeon Shin
SeongSeon Shin
SKSung-Min Kwon
Sung-Min Kwon
CKChiYen Kim
ChiYen Kim
JLJongHoon Lee
JongHoon Lee
JHJunHo Hwang Hwang
JunHo Hwang Hwang
HKHyun Deok Kim
Hyun Deok Kim

22 September 2023 in Journal of Functional Biomaterials
Verified
Journal Article
Open access
PDF file
SBSoo Kyum Bihn
Soo Kyum Bihn
KeunBaDa SonKeunBaDa Son
KeunBaDa Son
YSYoung-Tak Son
Young-Tak Son
Ram Hari DahalRam Hari Dahal
Ram Hari Dahal
SKShukho Kim
Shukho Kim
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
(1) Background: The purpose of this study was to evaluate how a zirconia implant surface treated with laser technology affects the degree of biofilm formation. (2) Methods: Experimental titanium (Ti) disks were produced that were sandblasted with large grit and acid-etched (T), and they were compared with zirconia (ZrO2) discs with a machined (M) surface topography; a hydrophilic surface topography with a femtosecond laser (HF); and a hydrophobic surface topography with a nanosecond laser (HN) (N = 12 per surface group). An in vitro three-species biofilm sample (Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi)) was applied to each disc type, and bacterial adhesion was assessed after 48 and 72 h of incubation using an anaerobic flow chamber model. Statistical significance was determined using the Kruskal–Wallis H test, with Bonferroni correction used for the post-hoc test (α = 0.05). (3) Results: Compared to the T group, the M group exhibited more than twice as many viable bacterial counts in the three-species biofilm samples (p < 0.05). In comparison to the T group, the HF group had significantly higher viable bacterial counts in certain biofilm samples at 48 h (Aa and Pi) and 72 h (Pi) (p < 0.05). The HN group had higher viable bacterial counts in Pi at 48 h (5400 CFU/mL, p < 0.05) than the T group (4500 CFU/mL), while showing significantly lower viable bacterial counts in Pg at both 48 (3010 CFU/mL) and 72 h (3190 CFU/mL) (p < 0.05). (4) Conclusions: The surface treatment method for zirconia discs greatly influences biofilm formation. Notably, hydrophobic surface treatment using a nanosecond laser was particularly effective at inhibiting Pg growth.