Daewoon Seong

Mr. Daewoon Seong

School of Electronics Engineering, College of IT engineering, Kyungpook National University, Daegu 41566, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
DSDaewoon Seong
Daewoon Seong
DJDeokmin Jeon
Deokmin Jeon
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
KPKibeom Park
Kibeom Park
HKHyeree Kim
Hyeree Kim
JKJeehyun Kim
Jeehyun Kim
The primary optimization of the imaging speed of optical coherence tomography (OCT) has been keenly studied. In order to overcome the major speed limitation of spectral-domain OCT (SD-OCT), we developed an ultrahigh-speed SD-OCT system, with an A-scan rate of up to 1 MHz, using the method of space–time-division multiplexing (STDM). Multicameras comprising a single spectrometer were implemented in the developed ultrahigh-speed STDM method to eliminate the dead time of operation, whereas STDM was simultaneously employed to enable wide-range scanning measurements at a high speed. By successfully integrating the developed STDM method with GPU parallel processing, 8 vol/s for an image range of $250\times 250\times2048$ pixels ( $9\times 4.5\times 5$ mm) was achieved, with an adjustable volume rate according to the required scanning speed and range. The examined STDM-OCT results of the customized optical thin film confirmed its feasibility for various fields that require rapid and wide-field scanning.

30 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SSSm Abu Saleah
Sm Abu Saleah
SKShinheon Kim
Shinheon Kim
JLJannat Amrin Luna
Jannat Amrin Luna
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
DSDaewoon Seong
Daewoon Seong
Mansik JeonMansik Jeon
Mansik Jeon
Characterizing plant material is crucial in terms of early disease detection, pest control, physiological assessments, and growth monitoring, which are essential parameters to increase production in agriculture and prevent unnecessary economic losses. The conventional methods employed to assess the aforementioned parameters have several limitations, such as invasive inspection, complexity, high time consumption, and costly features. In recent years, optical coherence tomography (OCT), which is an ultra-high resolution, non-invasive, and real-time unique image-based approach has been widely utilized as a significant and potential tool for assessing plant materials in numerous aspects. The obtained OCT cross-sections and volumetrics, as well as the amplitude signals of plant materials, have the capability to reveal vital information in both axial and lateral directions owing to the high resolution of the imaging system. This review discusses recent technological trends and advanced applications of OCT, which have been potentially adapted for numerous agricultural applications, such as non-invasive disease screening, optical signals-based growth speed detection, the structural analysis of plant materials, and microbiological discoveries. Therefore, this review offers a comprehensive exploration of recent advanced OCT technological approaches for agricultural applications, which provides insights into their potential to incorporate OCT technology into numerous industries.

7 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoonseok Kim
Yoonseok Kim
Gu-In JungGu-In Jung
Gu-In Jung
DJDeokmin Jeon
Deokmin Jeon
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
DSDaewoon Seong
Daewoon Seong
JKJeehyun Kim
Jeehyun Kim
The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.

20 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
DSDaewoon Seong
Daewoon Seong
JKJaehwan Kwon
Jaehwan Kwon
DJDeokmin Jeon
Deokmin Jeon
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
JLJaeyul Lee
Jaeyul Lee
JKJeehyun Kim
Jeehyun Kim
Non-invasive characterization of micro-vibrations in the tympanic membrane (TM) excited by external sound waves is considered as a promising and essential diagnosis in modern otolaryngology. To verify the possibility of measuring and discriminating the vibrating pattern of TM, here we describe a micro-vibration measurement method of latex membrane resembling the TM. The measurements are obtained with an externally generated audio stimuli of 2.0, 2.2, 2.8, 3.1 and 3.2 kHz, and their respective vibrations based tomographic, volumetric and quantitative evaluations were acquired using optical Doppler tomography (ODT). The micro oscillations and structural changes which occurred due to diverse frequencies are measured with sufficient accuracy using a highly sensitive ODT system implied phase subtraction method. The obtained results demonstrated the capability of measuring and analyzing the complex varying micro-vibration of the membrane according to implied sound frequency.

11 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SSSm Abu Saleah
Sm Abu Saleah
DSDaewoon Seong
Daewoon Seong
SHSangyeob Han
Sangyeob Han
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
JKJeehyun Kim
Jeehyun Kim
Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a limited portion of the sample by utilizing unidirectional and bidirectional scanning methods. Therefore, in this paper an integrated quad-scanner (QS) strategy-based OCT method was implemented to obtain the whole-directional volumetry of a sample by employing four scanning arms installed around the sample. The simultaneous and sequential image acquisition capabilities are the conceptual key points of the proposed QS-OCT method, and were implemented using four precisely aligned scanning arms and applied in a complementary way according to the experimental criteria. To assess the feasibility of obtaining whole-directional morphological structures, a roll of Scotch tape, an ex vivo mouse heart, and kidney specimens were imaged and independently obtained tissue images at different directions were delicately merged to compose the 3D volume data set. The results revealed the potential merits of QS-OCT-based whole-directional imaging, which can be a favorable inspection method for various discoveries that require the dynamic coordinates of the whole physical structure.

30 July 2021 in Photonics
Verified
Journal Article
Open access
PDF file
DSDaewoon Seong
Daewoon Seong
SHSangyeob Han
Sangyeob Han
JLJaeyul Lee
Jaeyul Lee
ELEuimin Lee
Euimin Lee
YKYoonseok Kim
Yoonseok Kim
JKJeehyun Kim
Jeehyun Kim
Photoacoustic imaging (PAI) is a hybrid non-invasive imaging technique used to merge high optical contrast and high acoustic resolution in deep tissue. PAI has been extensively developed by utilizing its advantages that include deep imaging depth, high resolution, and label-free imaging. As a representative implementation of PAI, photoacoustic microscopy (PAM) has been used in preclinical and clinical studies for its micron-scale spatial resolution capability with high optical absorption contrast. Several handheld and portable PAM systems have been developed that improve its applicability to several fields, making it versatile. In this study, we developed a laboratory-customized, two-axis, waterproof, galvanometer scanner-based handheld PAM (WP-GVS-HH-PAM), which provides an extended field of view (14.5 × 9 mm2) for wide-range imaging. The fully waterproof handheld probe enables free movement for imaging regardless of sample shape, and volume rate and scanning region are adjustable per experimental conditions. Results of WP-GVS-HH-PAM-based phantom and in vivo imaging of mouse tissues (ear, iris, and brain) confirm the feasibility and applicability of our system as an imaging modality for various biomedical applications.