Berenice Anina Dedavid

Berenice Anina Dedavid

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Cerâmica
Verified
Journal Article
Open access
PDF file
RAR. C. Abruzzi
R. C. Abruzzi
BDBerenice Anina Dedavid
Berenice Anina Dedavid
MPMarçal JOSE RODRIGUES Pires
Marçal JOSE RODRIGUES Pires
Tin dioxide (SnO2) is a promising material with great potential for applications such as gas sensors and catalysts. Nanostructures of this oxide exhibit greater activation efficiency given their larger effective surface. The present study presents results of the synthesis and characterization of tin dioxide under different conditions via oxidation of solid tin with nitric oxide. SnO2 powder was characterized primarily by X-ray diffraction and scanning electron microscopy, as well as complementary techniques such as energy-dispersive X-ray spectroscopy, dynamic light scattering and Fourier transform infrared spectroscopy. The results indicated that the established synthesis conditions were suitable for obtaining rutile tin dioxide nanoparticles with a tetragonal crystal structure.

5 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Sergio GehrkeSergio Gehrke
Sergio Gehrke
JJJaime Aramburú Junior
Jaime Aramburú Junior
Leticia Perez DiazLeticia Perez Diaz
Leticia Perez Diaz
TTTiago Treichel
Tiago Treichel
BDBerenice Anina Dedavid
Berenice Anina Dedavid
Juan-Carlos Prados-FrutosJuan-Carlos Prados-Frutos
Juan-Carlos Prados-Frutos
A new implant design with healing chambers in the threads was analyzed and compared with a conventional implant macrogeometry, both implants models with and without surface treatment. Eighty conical implants were prepared using commercially pure titanium (grade IV) by the company Implacil De Bortoli (São Paulo, Brazil). Four groups were performed, as described below: Group 1 (G1), traditional conical implants with surface treatment; group 2 (G2), traditional conical implants without surface treatment (machined surface); group 3 (G3), new conical implant design with surface treatment; group 4 (G4), new conical implant design without surface treatment. The implants were placed in the two tibias (n = 2 implants per tibia) of twenty New Zealand rabbits determined by randomization. The animals were euthanized after 15 days (Time 1) and 30 days (Time 2). The parameters evaluated were the implant stability quotient (ISQ), removal torque values (RTv), and histomorphometric evaluation to determine the bone to implant contact (%BIC) and bone area fraction occupancy (BAFO%). The results showed that the implants with the macrogeometry modified with healing chambers in the threads produced a significant enhancement in the osseointegration, accelerating this process. The statistical analyses of ISQ and RTv showed a significative statistical difference between the groups in both time periods of evaluation (p ≤ 0.0001). Moreover, an important increase in the histological parameters were found for groups G3 and G4, with significant statistical differences to the BIC% (in the Time 1 p = 0.0406 and in the Time 2 p < 0.0001) and the BAFO% ((in the Time 1 p = 0.0002 and in the Time 2 p = 0.0045). In conclusion, the result data showed that the implants with the new macrogeometry, presenting the healing chambers in the threads, produced a significant enhancement in the osseointegration, accelerating the process.

14 May 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Sergio GehrkeSergio Gehrke
Sergio Gehrke
JAJaime Aramburú
Jaime Aramburú
LPLeticia Pérez-Díaz
Leticia Pérez-Díaz
TPTales Dias Do Prado
Tales Dias Do Prado
BDBerenice Anina Dedavid
Berenice Anina Dedavid
Piedad De AzaPiedad De Aza
Piedad De Aza
The propose was to compare this new implant macrogeometry with a control implant with a conventional macrogeometry. Eighty-six conical implants were divided in two groups (n = 43 per group): group control (group CON) that were used conical implants with a conventional macrogeometry and, group test (group TEST) that were used implants with the new macrogeometry. The new implant macrogeometry show several circular healing cambers between the threads, distributed in the implant body. Three implants of each group were used to scanning electronic microscopy (SEM) analysis and, other eighty samples (n = 40 per group) were inserted the tibia of ten rabbit (n = 2 per tibia), determined by randomization. The animals were sacrificed (n = 5 per time) at 3-weeks (Time 1) and at 4-weeks after the implantations (Time 2). The biomechanical evaluation proposed was the measurement of the implant stability quotient (ISQ) and the removal torque values (RTv). The microscopical analysis was a histomorphometric measurement of the bone to implant contact (%BIC) and the SEM evaluation of the bone adhered on the removed implants. The results showed that the implants of the group TEST produced a significant enhancement in the osseointegration in comparison with the group CON. The ISQ and RTv tests showed superior values for the group TEST in the both measured times (3- and 4-weeks), with significant differences (p < 0.05). More residual bone in quantity and quality was observed in the samples of the group TEST on the surface of the removed implants. Moreover, the %BIC demonstrated an important increasing for the group TEST in both times, with statistical differences (in Time 1 p = 0.0103 and in Time 2 p < 0.0003). Then, we can conclude that the alterations in the implant macrogeometry promote several benefits on the osseointegration process.

1 December 2012 in Revista Árvore
Verified
Journal Article
Open access
PDF file
RARafael Colombo Abruzzi
Rafael Colombo Abruzzi
MPMarçal JOSE RODRIGUES Pires
Marçal JOSE RODRIGUES Pires
BDBerenice Anina Dedavid
Berenice Anina Dedavid
SKSilvia Baptista Kalil
Silvia Baptista Kalil
Este trabalho apresenta correlações obtidas entre propriedades mecânicas, densidade e o estado de deterioração de postes de eucalipto novos e retirados de serviço. O estado de deterioração foi determinado por inspeções em campo de postes da rede de distribuição de energia elétrica no sul do Brasil. Postes em diferentes estados de deterioração foram retirados da rede para os ensaios de flexão estática e medidas de densidade. Os testes mecânicos indicaram que os valores médios da resistência a flexão e da rigidez decrescem com o estado de deterioração do eucalipto. Entretanto, verificou-se uma grande variação nessas medidas com diferentes classes de deterioração apresentando resistência mecânica residual similar. Esse comportamento pode ser explicado pela influência da densidade da madeira nas correlações entre propriedades mecânicas e o estado de deterioração dos postes. Madeiras menos densas podem apresentar baixa resistência mecânica residual mesmo sem apresentar sinais de deterioração. O estudo da caracterização da madeira de eucalipto indicou que o estado de deterioração avaliado pela inspeção em campo, por si só não é um bom indicativo para prever a durabilidade das estruturas de madeiras, fazendo-se necessária uma análise preliminar da densidade da mesma.

6 August 2020 in Biology
Verified
Journal Article
Open access
PDF file
Sergio GehrkeSergio Gehrke
Sergio Gehrke
RBRaphaél Bettach
Raphaél Bettach
BCBenoit Cayron
Benoit Cayron
GBGilles Boukhris
Gilles Boukhris
BDBerenice Anina Dedavid
Berenice Anina Dedavid
Juan-Carlos Prados-FrutosJuan-Carlos Prados-Frutos
Juan-Carlos Prados-Frutos
The present in vitro study evaluated a new drill design to improve the temperature control during the osteotomies for dental implant installation, comparing with two drill designs that use conventional external irrigation. Three blocks of synthetic cortical bone were used for osteotomy procedures. Three groups were created: control group 1 (Con1), where a conical multiple drill system with a conventional external irrigation system was used; control group 2 (Con2), where a single bur with a conventional external irrigation system was used; and, test group (Test), where the new single bur (turbo drill) with a new irrigation system was used. Twenty osteotomies were made without irrigation and with intense irrigation, for each group. A thermocouple was used to measure the temperature produced during the osteotomies. The measured temperature were: 28.9 ± 1.68 °C for group Con1; 27.5 ± 1.32 °C for group Con2; 26.3 ± 1.28 °C for group Test. Whereas, the measured temperatures with irrigation were: 23.1 ± 1.27 °C for group Con1; 21.7 ± 1.36 °C for group Con2; 19.4 ± 1.29 °C for group Test. The single drill with a new design for improving the irrigation and temperature control, in comparison with the drill designs with conventional external irrigation.

1 April 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
Sergio GehrkeSergio Gehrke
Sergio Gehrke
BDBerenice Anina Dedavid
Berenice Anina Dedavid
Gustavo FernandesGustavo Fernandes
Gustavo Fernandes
The objective of this study was to evaluate a new design of multifunctional abutment for Morse taper implant connections, relative to the retentive stability after the application of cyclic loads in cemented and screwed crowns. Multifunctional abutments with two different angulations in the seating portion of the crown were tested, forming 2 groups (n = 30 samples per group): Group Abut11, where Smart abutments with an angle of 11.42° were used; Group Abut5, where Ideale abutments with an angle of 5° were used. Fifteen samples from each group received cemented crowns (CC) and another fifteen screwed crowns (SC). All crown samples were subjected to the mechanical cycling test at 360,000 cycles at a frequency of 4 Hz and 150 N of the load. The samples with CC were subjected to the tensile test to remove the crowns, while in the samples with SC, the detorque value of the fastening crown screws was measured. The mean tensile strength value of CC in the Abut11 group was 131.9 ± 13.5 N and, in the Abut5 group was 230.9 ± 11.3 N; while the detorque mean value in samples with SC 5.8 ± 1.8 N for the Abut11 group and, 7.6 ± 1.1 N for Abut5 group. Significant statistical differences were found between the two groups in both situations tested (p < 0.05). The multifunctional abutments, presenting a lesser angulation of the crown-seating portion, showed higher values of retention of the CC and a lesser screw loosening of torque of the fixing screws in the SC after the application of cyclic loads when compared to the abutments with more angulation in the crown-seating portion.