Francesco Scardulla

Dr. Francesco Scardulla

Department of Engineering, University of Palermo, Viale delle Scienze, 90128 Palermo, Italy

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
LDLeonardo D'Acquisto
Leonardo D'Acquisto
RCRaffaele Colombarini
Raffaele Colombarini
Sijung HuSijung Hu
Sijung Hu
Salvatore PastaSalvatore Pasta
Salvatore Pasta
DBDiego Bellavia
Diego Bellavia
Heart rate (HR) as an important physiological indicator could properly describe global subject’s physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland–Altman plot within ±11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.

1 November 2015 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
PDF file
ARAntonino Rinaudo
Antonino Rinaudo
GRGiuseppe Raffa
Giuseppe Raffa
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
MPMichele Pilato
Michele Pilato
CSCesare Scardulla
Cesare Scardulla
Salvatore PastaSalvatore Pasta
Salvatore Pasta

23 October 2015 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
ARAntonino Rinaudo
Antonino Rinaudo
GRGiuseppe Raffa
Giuseppe Raffa
GDGiuseppe D’aNcona
Giuseppe D’aNcona
CSCesare Scardulla
Cesare Scardulla
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protrusion extension exhibited the maximum TAG device displacement (1.66 mm), while the lowest protrusion extension configuration led to the minimum amount of both displacement and rotation parameters (0.25 mm and 0.6°, respectively). A positive relationship was found between the infolding parameters and the flow circulating in the aorta and left subclavian artery. Similarly, TAG device displacement was positively and significantly (p<0.05) correlated with the pulse pressure for all bird-beak configurations and device sizes. However, no collapse was observed under chronic perfusion testing maintained for 30 days and pulse pressure of 100 mm Hg. Conclusion: These findings suggest that endograft infolding depends primarily on the amount of aortic pulsatility and flow rate and that physiological flows do not necessarily engender hemodynamic loads on the proximal bird-beak segment sufficient to cause TAG collapse. Hemodynamic variables may allow for identification of patients at high risk of endograft infolding and help guide preventive intervention to avert its occurrence.

12 July 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
DBDiego Bellavia
Diego Bellavia
LDLeonardo D'Acquisto
Leonardo D'Acquisto
GRGiuseppe Raffa
Giuseppe Raffa
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdominal aorta. Then, the distribution of wall shear stress (WSS) was estimated by computational flow analysis. At a cardiac output of 5 L/min, the highest flow division was found in the mesenteric artery (13.6% for PIV and 14.6% for echocardiography), while the left renal artery exhibited the lowest amount in the celiac trunk model (2.6% for PIV and 2.4% for echocardiography). Bland-Altman analysis demonstrated a high agreement between echocardiographic and PIV-related flow measurements, while computational flow analysis revealed that WSS was high in the LVAD graft anastomosis site and just after the ostia of both the celiac trunk and mesenteric artery. This altered shear stress distribution in the celiac trunk may lead to a flow-mediated mechanism of adverse remodeling of the von Willebrand factor and ultimately to gastrointestinal bleeding as seen clinically in this patient.

24 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Gianluca DianaGianluca Diana
Gianluca Diana
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
SPSilvia Puleo
Silvia Puleo
Salvatore PastaSalvatore Pasta
Salvatore Pasta
LDLeonardo D'Acquisto
Leonardo D'Acquisto
With advancing age, blood vessels undergo deterioration that causes structural and functional changes, including a progressive increase in arterial wall stiffness. Since arterial stiffness is closely linked to the potential risks of cardiovascular diseases, which remains the leading cause of global mortality, it has become essential to develop effective techniques for early diagnosis and continuous monitoring over time. Photoplethysmography, a low-cost and non-invasive technology that measures blood volume changes, has gained increasing popularity in recent years and has proven to be a potential valuable tool for estimating arterial stiffness. This study employs an in vitro experimental setup designed to simulate the cardiovascular system performing under controlled velocity and pressure conditions, in which silicone phantom models with different geometric and mechanical properties were implemented to evaluate their stiffness using a pair of photoplethysmographic sensors. These were employed to measure the pulse wave velocity, currently considered the reference technique for estimating arterial stiffness, correlated through the well-known Moens–Korteweg equation. Photoplethysmographic sensors were placed at three specific distances to determine an optimal configuration for assessing arterial stiffness. Results showed the best performance for softer vascular models at a 15 cm sensor distance, with measurements demonstrating satisfactory accuracy. Variability and standard deviation values increased with model stiffness. The aim of this study is to improve the use of photoplethysmographic sensors for monitoring the mechanical properties of blood vessels and, therefore, to prevent potential cardiovascular diseases.

18 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
Gloria CosoliGloria Cosoli
Gloria Cosoli
CGCosmina Gnoffo
Cosmina Gnoffo
LALuca Antognoli
Luca Antognoli
FBFrancesco Bongiorno
Francesco Bongiorno
Marco ArnesanoMarco Arnesano
Marco Arnesano
Photoplethysmographic (PPG) sensors are small and cheap wearable sensors which open the possibility of monitoring physiological parameters such as heart rate during normal daily routines, ultimately providing valuable information on health status. Despite their potential and distribution within wearable devices, their accuracy is affected by several influencing parameters, such as contact pressure and physical activity. In this study, the effect of contact pressure (i.e., at 20, 60, and 75 mmHg) and intensity of physical activity (i.e., at 3, 6, and 8 km/h) were evaluated on a sample of 25 subjects using both a reference device (i.e., an electrocardiography-based device) and a PPG sensor applied to the skin with controlled contact pressure values. Results showed differing accuracy and precision when measuring the heart rate at different pressure levels, achieving the best performance at a contact pressure of 60 mmHg, with a mean absolute percentage error of between 3.36% and 6.83% depending on the physical activity levels, and a Pearson’s correlation coefficient of between 0.81 and 0.95. Plus, considering the individual optimal contact pressure, measurement uncertainty significantly decreases at any contact pressure, for instance, decreasing from 15 bpm (at 60 mmHg) to 8 bpm when running at a speed of 6 km/h (coverage factor k = 2). These results may constitute useful information for both users and manufacturers to improve the metrological performance of PPG sensors and expand their use in a clinical context.