Leonardo D'Acquisto

Prof. Leonardo D'Acquisto

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Measurement
Verified
Journal Article
Closed access
Gloria CosoliGloria Cosoli
Gloria Cosoli
Susanna SpinsanteSusanna Spinsante
Susanna Spinsante
FSFrancesco Scardulla
Francesco Scardulla
LDLeonardo D'Acquisto
Leonardo D'Acquisto
LSLorenzo Scalise
Lorenzo Scalise

5 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
LDLeonardo D'Acquisto
Leonardo D'Acquisto
RCRaffaele Colombarini
Raffaele Colombarini
Sijung HuSijung Hu
Sijung Hu
Salvatore PastaSalvatore Pasta
Salvatore Pasta
DBDiego Bellavia
Diego Bellavia
Heart rate (HR) as an important physiological indicator could properly describe global subject’s physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland–Altman plot within ±11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.

12 July 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
DBDiego Bellavia
Diego Bellavia
LDLeonardo D'Acquisto
Leonardo D'Acquisto
GRGiuseppe Raffa
Giuseppe Raffa
Salvatore PastaSalvatore Pasta
Salvatore Pasta
Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdominal aorta. Then, the distribution of wall shear stress (WSS) was estimated by computational flow analysis. At a cardiac output of 5 L/min, the highest flow division was found in the mesenteric artery (13.6% for PIV and 14.6% for echocardiography), while the left renal artery exhibited the lowest amount in the celiac trunk model (2.6% for PIV and 2.4% for echocardiography). Bland-Altman analysis demonstrated a high agreement between echocardiographic and PIV-related flow measurements, while computational flow analysis revealed that WSS was high in the LVAD graft anastomosis site and just after the ostia of both the celiac trunk and mesenteric artery. This altered shear stress distribution in the celiac trunk may lead to a flow-mediated mechanism of adverse remodeling of the von Willebrand factor and ultimately to gastrointestinal bleeding as seen clinically in this patient.

24 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Gianluca DianaGianluca Diana
Gianluca Diana
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
SPSilvia Puleo
Silvia Puleo
Salvatore PastaSalvatore Pasta
Salvatore Pasta
LDLeonardo D'Acquisto
Leonardo D'Acquisto
With advancing age, blood vessels undergo deterioration that causes structural and functional changes, including a progressive increase in arterial wall stiffness. Since arterial stiffness is closely linked to the potential risks of cardiovascular diseases, which remains the leading cause of global mortality, it has become essential to develop effective techniques for early diagnosis and continuous monitoring over time. Photoplethysmography, a low-cost and non-invasive technology that measures blood volume changes, has gained increasing popularity in recent years and has proven to be a potential valuable tool for estimating arterial stiffness. This study employs an in vitro experimental setup designed to simulate the cardiovascular system performing under controlled velocity and pressure conditions, in which silicone phantom models with different geometric and mechanical properties were implemented to evaluate their stiffness using a pair of photoplethysmographic sensors. These were employed to measure the pulse wave velocity, currently considered the reference technique for estimating arterial stiffness, correlated through the well-known Moens–Korteweg equation. Photoplethysmographic sensors were placed at three specific distances to determine an optimal configuration for assessing arterial stiffness. Results showed the best performance for softer vascular models at a 15 cm sensor distance, with measurements demonstrating satisfactory accuracy. Variability and standard deviation values increased with model stiffness. The aim of this study is to improve the use of photoplethysmographic sensors for monitoring the mechanical properties of blood vessels and, therefore, to prevent potential cardiovascular diseases.

18 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Francesco ScardullaFrancesco Scardulla
Francesco Scardulla
Gloria CosoliGloria Cosoli
Gloria Cosoli
CGCosmina Gnoffo
Cosmina Gnoffo
LALuca Antognoli
Luca Antognoli
FBFrancesco Bongiorno
Francesco Bongiorno
Marco ArnesanoMarco Arnesano
Marco Arnesano
Photoplethysmographic (PPG) sensors are small and cheap wearable sensors which open the possibility of monitoring physiological parameters such as heart rate during normal daily routines, ultimately providing valuable information on health status. Despite their potential and distribution within wearable devices, their accuracy is affected by several influencing parameters, such as contact pressure and physical activity. In this study, the effect of contact pressure (i.e., at 20, 60, and 75 mmHg) and intensity of physical activity (i.e., at 3, 6, and 8 km/h) were evaluated on a sample of 25 subjects using both a reference device (i.e., an electrocardiography-based device) and a PPG sensor applied to the skin with controlled contact pressure values. Results showed differing accuracy and precision when measuring the heart rate at different pressure levels, achieving the best performance at a contact pressure of 60 mmHg, with a mean absolute percentage error of between 3.36% and 6.83% depending on the physical activity levels, and a Pearson’s correlation coefficient of between 0.81 and 0.95. Plus, considering the individual optimal contact pressure, measurement uncertainty significantly decreases at any contact pressure, for instance, decreasing from 15 bpm (at 60 mmHg) to 8 bpm when running at a speed of 6 km/h (coverage factor k = 2). These results may constitute useful information for both users and manufacturers to improve the metrological performance of PPG sensors and expand their use in a clinical context.

5 March 2008 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ASAntonino M. Siddiolo
Antonino M. Siddiolo
LDLeonardo D'Acquisto
Leonardo D'Acquisto
In this paper, a methodology to process fringe patterns is presented. The core of the signal processing technique is the use of the direction information, which is a modulo quantity that locally indicates the direction along which fringes grow at a maximum rate. By using this information, it was possible to perform adaptive and direction/orientation-based operations on fringe images to remove unwanted effects (mainly distortions at the image borders), to enhance the contrast, and to extract the phase information encoded. The method has been applied on shadow-moire interferograms with carrier fringes in order to measure the surface of small objects. The developed algorithm allows processing of fringes whose phase information is not monotonically increasing everywhere and to more accurately estimate the phase itself. The results from two experimental fringe patterns are presented. These results are compared with the measurements that are performed by means of a conoscopic system that is used as a reference. Hence, it was possible to calculate the uncertainty of the performed measurements. Aside from the possibility of decoding fringe patterns that present closed fringes, the proposed method provides measurements that are characterized by an uncertainty that is more than halved compared with Fourier-based methods.