Power flow controllers and circuit breakers are important devices in a DC grid, and combining them and expanding their ports can save many components. This paper proposes an integrated multiport DC power flow controller with a DC circuit breaker that can achieve power flow control and fault removal on multiple DC lines during steady and fault states, respectively. First, the device's topology based on modular multilevel converters is proposed, and the principles of power flow control and self-power balance based on bridge arm voltage are introduced. Second, it is improved by adding a fault removal capability. The equivalent circuit and fault currents in different time sequences are analyzed, and the component parameter selection method is designed. Third, in the PSCAD/EMTDC, the power flow control and fault removal capabilities are verified using three conditions: flow control, line fault, and bus fault. Finally, the number of components and steady-state losses are analyzed. Overall, the proposed device has power flow control and fault removal functions as well as a certain limiting effect on the fault current, which greatly reduces the system construction cost.
Partial discharge (PD) detection can effectively achieve the status maintenance of XLPE (Cross Linked Polyethylene) cable, so it is the direction of the development of equipment maintenance in power systems. At present, a main method of PD detection is the broadband electromagnetic coupling with a high-frequency current transformer (HFCT). Due to the strong electromagnetic interference (EMI) generated among the mass amount of cables in a tunnel and the impedance mismatching of HFCT and the data acquisition equipment, the features of the pulse current generated by PD are often submerged in the background noise. The conventional method for the stationary signal analysis cannot analyze the PD signal, which is transient and non-stationary. Although the algorithm of Shannon wavelet singular entropy (SWSE) can be used to analyze the PD signal at some level, its precision and anti-interference capability of PD feature extraction are still insufficient. For the above problem, a novel method named Renyi wavelet packet singular entropy (RWPSE) is proposed and applied to the PD feature extraction on power cables. Taking a three-level system as an example, we analyze the statistical properties of Renyi entropy and the intrinsic correlation with Shannon entropy under different values of α . At the same time, discrete wavelet packet transform (DWPT) is taken instead of discrete wavelet transform (DWT), and Renyi entropy is combined to construct the RWPSE algorithm. Taking the grounding current signal from the shielding layer of XLPE cable as the research object, which includes the current pulse feature of PD, the effectiveness of the novel method is tested. The theoretical analysis and experimental results show that compared to SWSE, RWPSE can not only improve the feature extraction accuracy for PD, but also can suppress EMI effectively.
16 August 2019 in Journal of Electrical Engineering & Technology
To address the challenge of bird species detection on transmission lines, this paper proposes a detection method based on dual data enhancement and an improved YOLOv8s model. The method aims to improve the accuracy of identifying small- and medium-sized targets in bird detection scenes on transmission lines, while also accounting for the impact of changing weather conditions. To address these issues, a dual data enhancement strategy is introduced. The model’s generalization ability in outdoor environments is enhanced by simulating various weather conditions, including sunny, cloudy, and foggy days, as well as halo effects. Additionally, an improved Mosaic augmentation technique is proposed, which incorporates target density calculation and adaptive scale stitching. Within the improved YOLOv8s architecture, the CBAM attention mechanism is embedded in the Backbone network, and BiFPN replaces the original Neck module to facilitate bidirectional feature extraction and fusion. Experimental results demonstrate that the proposed method achieves high detection accuracy for all bird species, with an average precision rate of 94.2%, a recall rate of 89.7%, and an mAP@50 of 94.2%. The model also maintains high inference speed, demonstrating potential for real-time detection requirements. Ablation and comparative experiments validate the effectiveness of the proposed model, confirming its suitability for edge deployment and its potential as an effective solution for bird species detection and identification on transmission lines.
By using a soft normal open point (SNOP) to connect multiple distribution networks to form a flexible interconnected distribution system (FIDS), the power distribution can be flexibly and controllably regulated among distribution stations, but it is also necessary to ensure the system’s operational efficiency and maintain voltage quality when carrying out optimal scheduling. In this paper, a FIDS optimal scheduling strategy considering dynamic weight grading is proposed. By considering the voltage overrun status of each distribution station area, the voltage level of each distribution station area is divided into three voltage overrun situations, including normal operation, safe boundary, and protection boundary levels, and an optimal scheduling model applicable to the multi-level operation of the FIDS is constructed. In order to adapt to the coordinated optimal operation objectives under different overrun levels, an optimal operation strategy considering the dynamic weights of system operation cost, voltage deviation, customer satisfaction, and SNOP regulation capability is proposed and finally simulated and verified using the improved IEEE33 node arithmetic case. The results verify the effectiveness of the method proposed in this paper in improving the system’s operational efficiency and node voltage quality.