In order to smoothly connect to permanently disturbed grids, DFIG-based wind turbines must precisely synchronize the voltage induced at their open stator with that of the grid. Hence, aiming at addressing the still unpublished task of synchronizing DFIGs to simultaneously unbalanced and harmonically distorted grids, a phase-locked loop (PLL)-less and naturally chatter-free sliding-mode control (SMC) algorithm is proposed. The strategies developed so far were formulated considering synchronous reference frames. However, by designing a stationary reference frame-based solution, decomposition into positive- and negative-sequences and harmonic components is avoided. As a result, a relatively straightforward control structure with strong potential for industrialization is obtained, consisting of a single voltage loop per component with just one parameter to be tuned. The stability and robustness resulting from its application are analytically studied under both uncertainties and disturbances. Additionally, a simple method for rotor positioning, independent of grid disturbances, is provided. Simulation over a 2-MW DFIG model and rapid control prototyping (RCP) over a 7-kW DFIG experimental rig are carried out. In this way, the performance and robustness of the suggested control scheme are validated under both unbalanced and harmonically distorted grid voltage, substantial parameter deviations, and varying wind speed and grid frequency profiles.
In this paper, a posteriori multi-objective optimisation (MOO) is applied to tune the parameters of a second-order sliding-mode control (2-SMC) scheme commanding the grid-side converter (GSC) of a doubly-fed induction generator (DFIG) subject to unbalanced and harmonically distorted grid voltage. Two variants (i.e., design concepts) of the same 2-SMC algorithm are assessed, which only differ in the format of their switching functions and which contain six and four parameters to be adjusted, respectively. A single set of parameters which stays valid for nine different operating regimes of the DFIG is also sought. As two objectives, related to control performances of grid active and reactive powers, are established for each operating regime, the optimisation process considers 18 objectives simultaneously. A six-parameter set derived in a previous work without applying MOO is taken as reference solution. MOO results reveal that both the six- and four-parameter versions can be tuned to overcome said reference solution in each and every objective, as well as showing that performances comparable to those of the six-parameter variant can be achieved by adopting the four-parameter one. Overall, the experimental results confirm the latter and prove that the performance of the reference parameter set can be significantly improved by using either of the six- or four-parameter versions.
1 May 2023 in IEEE Transactions on Industrial Electronics
In this article, we propose an instantaneous complex power control (ICPC) for a grid-tied voltage-source converter, which has two important features: it allows injecting currents with low distortion to the grid, and it allows to significantly reduce the value of the dc link capacitor, which can potentially increase the reliability of the system and decrease its cost (considering different capacitor technologies). The proposal is based on finding the exact active power reference that the controller requires to keep the mean value of the energy in the dc link constant at all times. This means that, even when the loading conditions change, the mean value of the dc link voltage remains unchanged, allowing the reduction of the value of dc link capacitor. The proposed control scheme is validated both through simulations and experimental results.
This paper proposes a solution for the self-synchronization of grid-tied feeding inverters. Since the proposed algorithm allows the self-synchronization, it avoids using a voltage sensor for measuring the Point of Common Coupling (PCC) voltage. The algorithm is based on an adaptive non-linear observer that uses the measurement of the output inductor current. Unlike synchronization schemes based on the virtual synchronous generator, which is often used in control strategies based on power synchronization, when combined with a non-linear control strategy, the proposed algorithm allows obtaining an excellent dynamic performance, even in presence of large PCC voltage disturbances and fast varying references. The performance of the proposed observer when combined with a non-linear control strategy, designed by considering the non-linear model of the converter, is illustrated through experimental results.
In this document, a nonlinear control law for a grid-tied converter is introduced. The converter topology consists of a voltage source inverter (VSI) linked to the grid through an inductive-capacitive second-order filter, its input being connected to a capacitive DC-link supplied by a renewable energy-based input power source. In order to achieve good performance in presence of large state excursions caused mainly by substantial set-point modifications and/or considerable disturbances, a nonlinear control law based on a complex-valued feedback linearization strategy is designed. Specifically, a flat output is adopted, which is given by the summation of the energy stored in the DC-link capacitor and in the output filter's inductor and capacitor, as well as by the reactive energy at the output. After linearizing the system through a pertinent coordinate transformation and a nonlinear feedback, a linear trajectory tracking control law is implemented. The performance of the system controlled by applying the proposed strategy is tested via simulation for a very weak grid of unity X/R ratio, yielding satisfactory results.