Miren Itsaso Martínez Aguirre

Miren Itsaso Martínez Aguirre


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
ASAna Susperregui
Ana Susperregui
MAMiren Itsaso Martínez Aguirre
Miren Itsaso Martínez Aguirre
GOGerardo Tapia Otaegui
Gerardo Tapia Otaegui
AEAitor Etxeberria
Aitor Etxeberria
In order to smoothly connect to permanently disturbed grids, DFIG-based wind turbines must precisely synchronize the voltage induced at their open stator with that of the grid. Hence, aiming at addressing the still unpublished task of synchronizing DFIGs to simultaneously unbalanced and harmonically distorted grids, a phase-locked loop (PLL)-less and naturally chatter-free sliding-mode control (SMC) algorithm is proposed. The strategies developed so far were formulated considering synchronous reference frames. However, by designing a stationary reference frame-based solution, decomposition into positive- and negative-sequences and harmonic components is avoided. As a result, a relatively straightforward control structure with strong potential for industrialization is obtained, consisting of a single voltage loop per component with just one parameter to be tuned. The stability and robustness resulting from its application are analytically studied under both uncertainties and disturbances. Additionally, a simple method for rotor positioning, independent of grid disturbances, is provided. Simulation over a 2-MW DFIG model and rapid control prototyping (RCP) over a 7-kW DFIG experimental rig are carried out. In this way, the performance and robustness of the suggested control scheme are validated under both unbalanced and harmonically distorted grid voltage, substantial parameter deviations, and varying wind speed and grid frequency profiles.

1 July 2017 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
MAMiren Itsaso Martínez Aguirre
Miren Itsaso Martínez Aguirre
ASAna Susperregui
Ana Susperregui
GTGerardo Tapia
Gerardo Tapia
Control algorithms for both the rotor‐ and grid‐side power converters of a wind turbine‐driven doubly‐fed induction generator (DFIG) are detailed, and tuning equations are also provided to assist adjustment of their gains and constants. Those algorithms are based on the second‐order sliding‐mode control (2‐SMC) approach, and they allow the wind turbine to satisfactorily operate under grid voltage non‐idealities, such as simultaneously distorted and unbalanced scenarios. The presented solution turns out to be robust against parameter deviations and disturbances, and of high‐performance dynamic response. Moreover, it drives the transistors of both power converters at a constant switching frequency, also avoiding decomposition in symmetrical sequences of either the grid voltage or currents. The controllers proposed for the two power converters are validated through experimentation on a 7‐kW DFIG test bench subject to a significantly unbalanced and harmonically distorted grid voltage. Their robustness in the presence of both substantial parameter mismatch and disturbances attributable to wind variability is also assessed.

5 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
ASAna Susperregui
Ana Susperregui
JHJuan Herrero
Juan Herrero
MAMiren Itsaso Martínez Aguirre
Miren Itsaso Martínez Aguirre
GOGerardo Tapia Otaegui
Gerardo Tapia Otaegui
Xavier BlascoXavier Blasco
Xavier Blasco
In this paper, a posteriori multi-objective optimisation (MOO) is applied to tune the parameters of a second-order sliding-mode control (2-SMC) scheme commanding the grid-side converter (GSC) of a doubly-fed induction generator (DFIG) subject to unbalanced and harmonically distorted grid voltage. Two variants (i.e., design concepts) of the same 2-SMC algorithm are assessed, which only differ in the format of their switching functions and which contain six and four parameters to be adjusted, respectively. A single set of parameters which stays valid for nine different operating regimes of the DFIG is also sought. As two objectives, related to control performances of grid active and reactive powers, are established for each operating regime, the optimisation process considers 18 objectives simultaneously. A six-parameter set derived in a previous work without applying MOO is taken as reference solution. MOO results reveal that both the six- and four-parameter versions can be tuned to overcome said reference solution in each and every objective, as well as showing that performances comparable to those of the six-parameter variant can be achieved by adopting the four-parameter one. Overall, the experimental results confirm the latter and prove that the performance of the reference parameter set can be significantly improved by using either of the six- or four-parameter versions.

1 May 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SJSebastian Gomez Jorge
Sebastian Gomez Jorge
JSJorge Solsona
Jorge Solsona
CBClaudio A. Busada
Claudio A. Busada
GOGerardo Tapia Otaegui
Gerardo Tapia Otaegui
ASAna Susperregui
Ana Susperregui
MAMiren Itsaso Martínez Aguirre
Miren Itsaso Martínez Aguirre
In this article, we propose an instantaneous complex power control (ICPC) for a grid-tied voltage-source converter, which has two important features: it allows injecting currents with low distortion to the grid, and it allows to significantly reduce the value of the dc link capacitor, which can potentially increase the reliability of the system and decrease its cost (considering different capacitor technologies). The proposal is based on finding the exact active power reference that the controller requires to keep the mean value of the energy in the dc link constant at all times. This means that, even when the loading conditions change, the mean value of the dc link voltage remains unchanged, allowing the reduction of the value of dc link capacitor. The proposed control scheme is validated both through simulations and experimental results.

10 January 2025 in Control Engineering Practice
Verified
Journal Article
Open access
GOGerardo Tapia Otaegui
Gerardo Tapia Otaegui
SJSebastián Gómez Jorge
Sebastián Gómez Jorge
JSJorge A. Solsona
Jorge A. Solsona
ASAna Susperregui
Ana Susperregui
MAMiren Itsaso Martínez Aguirre
Miren Itsaso Martínez Aguirre
CBClaudio A. Busada
Claudio A. Busada

18 October 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SJSebastian Gomez Jorge
Sebastian Gomez Jorge
JSJorge Solsona
Jorge Solsona
CBClaudio A. Busada
Claudio A. Busada
GOGerardo Tapia Otaegui
Gerardo Tapia Otaegui
ASAna Susperregui
Ana Susperregui
MAMiren Itsaso Martínez Aguirre
Miren Itsaso Martínez Aguirre
This paper proposes a solution for the self-synchronization of grid-tied feeding inverters. Since the proposed algorithm allows the self-synchronization, it avoids using a voltage sensor for measuring the Point of Common Coupling (PCC) voltage. The algorithm is based on an adaptive non-linear observer that uses the measurement of the output inductor current. Unlike synchronization schemes based on the virtual synchronous generator, which is often used in control strategies based on power synchronization, when combined with a non-linear control strategy, the proposed algorithm allows obtaining an excellent dynamic performance, even in presence of large PCC voltage disturbances and fast varying references. The performance of the proposed observer when combined with a non-linear control strategy, designed by considering the non-linear model of the converter, is illustrated through experimental results.