Arianna Goi

Ms. Arianna Goi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in Journal of Dairy Science
Verified
Journal Article
Open access
ACAngela Costa
Angela Costa
NSNicholas William Sneddon
Nicholas William Sneddon
AGArianna Goi
Arianna Goi
GVGiulio Visentin
Giulio Visentin
LMLudovica Mammi
Ludovica Mammi
MMMassimo De Marchi
Massimo De Marchi
Mammalian colostrum, known as "liquid gold," is considered a valuable source of essential nutrients, growth factors, probiotics, prebiotics, antibodies, and other bioactive compounds. Precisely for this reason, bovine colostrum (BC) is an emerging ingredient for the feed, food, and pharmaceutical industries, being nowadays commercially available in a variety of forms in several countries. Moreover, quite a large number of functional foods and supplements for athletes, human medicines, pet nutrition plans, and complementary feed for some livestock categories, such as piglets and calves, contain BC. The amount of BC yielded by a cow after calving represents approximately 0.5% of the yearly output in dairy breeds. For its nutritional properties and low availability, BC is characterized by a greater market value and an increasing demand compared with other by-products of the dairy sector. However, information regarding the market size of BC for the food and pharmaceutical industries, as well as future developments and perspectives, is scarcely available in the scientific literature. This lack can be attributed to industrial secrecy as well as to the relatively small scale of the BC business when compared with other dairy products, which makes the BC market limited, specific, and intended for a restricted audience. From a legal perspective, regulations assign BC to the large family of milk-derived powders; thus, collecting specific production data, as well as import-export trend information, is not straightforward and can result in unprecise estimates. Given that the interest in BC is increasing in different fields, it is important to have an overview of the production steps and of pros and cons of this emerging ingredient. The present narrative review discloses why BC has started to be considered a product rather than a by-product of the dairy industry. Moreover, the present document aims to summarize the existing methodologies used to assess BC quality in terms of immunoglobulin concentration, the different applications of BC in the industry, and the BC processing technologies. Finally, a panoramic view of the current international market is provided for the first time for this dairy product.

20 March 2023 in Meat Science
Verified
Journal Article
Open access
MKMoïse Kombolo-Ngah
Moïse Kombolo-Ngah
AGArianna Goi
Arianna Goi
MSMatteo Santinello
Matteo Santinello
NRNicola Rampado
Nicola Rampado
SAStefka Atanassova
Stefka Atanassova
JHJean-François Hocquette
Jean-François Hocquette
Only few studies have used Near-Infrared (NIR) spectroscopy to assess meat quality traits directly in the chiller. The aim of this study was therefore to investigate the ability of a handheld NIR spectrometer to predict marbling scores on intact meat muscles in the chiller. A total of 829 animals from 2 slaughterhouses in France and Italy were involved. Marbling was assessed according to the 3G (Global Grading Guaranteed) protocol using 2 different scores. NIR measurements were collected by performing 5 scans at different points of the Longissimus thoracis. An average MSA marbling score of 330-340 was obtained in the two countries. The prediction models provided a R2 in external validation between 0.46 and 0.59 and a standard error of prediction between 83.1 and 105.5. Results did provide a moderate prediction of the marbling scores but can be useful in the European industry context to predict classes of MSA marbling.

10 November 2021 in Genetics Selection Evolution
Verified
Journal Article
Open access
PDF file
ACAngela Costa
Angela Costa
MFMarco Franzoi
Marco Franzoi
GVGiulio Visentin
Giulio Visentin
AGArianna Goi
Arianna Goi
MMMassimo De Marchi
Massimo De Marchi
Mauro PenasaMauro Penasa
Mauro Penasa
Background: The quality of colostrum administered to calves is based on its concentration in immunoglobulins G (IgG, g/L). Immunoglobulins A (IgA) and M (IgM) are also present but at a lower level. The gold standard reference analysis for these traits, radial immunodiffusion, is time-consuming and expensive. In order to define breeding strategies that are aimed at improving colostrum quality in dairy cattle, a large amount of data is needed, and the use of indicator traits would be beneficial. In the study presented here, we explored the heritabilities of reference (radial immunodiffusion) and near infrared-predicted IgG, IgA, and IgM concentrations and estimated their genetic correlations. First, the colostrum of 765 Holstein cows from nine herds was sampled to perform a reference analysis and the near-infrared spectra (400–2500 nm) were stored. We used a calibration set (28% of the initial samples) that was representative of the herds and cow parity orders to develop prediction equations for IgG, IgA, and IgM concentrations. Finally, these traits were predicted in the validation set (72% of the initial samples) to estimate genetic parameters for the predictions. Genetic correlations between reference and predicted values of each trait were estimated through bivariate linear animal models. Results: The three near-infrared-predicted immunoglobulin fractions were genetically correlated with their reference value. In particular, the reference and predicted IgG concentrations were strongly correlated at both the genetic (0.854 ± 0.314) and phenotypic level (0.767 ± 0.019). Weaker associations were observed for IgA and IgM concentrations, which were predicted with lower accuracy compared to IgG. Simulation analyses suggested that improving colostrum quality by selective breeding in Holstein cattle based on near-infrared predicted colostrum immunoglobulins concentrations is feasible. In addition, less than 10 mL of colostrum are needed for spectra acquisition and thus implementation of such analyses is possible in the near future. Conclusions: The concentrations of colostrum immunoglobulins can be predicted from near-infrared spectra and the genetic correlation between the reference and the predicted traits is positive and favourable, in spite of the large standard errors of the estimates. Near-infrared spectroscopy can be exploited in selective breeding of dairy cattle to improve colostral immunoglobulins concentration.

1 September 2019 in Animals
Verified
Journal Article
Open access
PDF file
AGArianna Goi
Arianna Goi
CMCarmen L. Manuelian
Carmen L. Manuelian
SCSarah Currò
Sarah Currò
MMMassimo De Marchi
Massimo De Marchi
The pet food industry is interested in performing fast analyses to control the nutritional quality of their products. This study assessed the feasibility of near-infrared spectroscopy to predict mineral content in extruded dry dog food. Mineral content in commercial dry dog food samples (n = 119) was quantified by inductively coupled plasma optical emission spectrometry and reflectance spectra (850–2500 nm) captured with FOSS NIRS DS2500 spectrometer. Calibration models were built using modified partial least square regression and leave-one-out cross-validation. The best prediction models were obtained for S (coefficient of determination; R2 = 0.89), K (R2 = 0.85), and Li (R2 = 0.74), followed by P, B, and Sr (R2 = 0.72 each). Only prediction models for S and K were adequate for screening purposes. This study supports that minerals are difficult to determine with NIRS if they are not associated with organic molecules.

16 September 2020 in Animals
Verified
Journal Article
Open access
PDF file
AGArianna Goi
Arianna Goi
MSMARICA SIMONI
MARICA SIMONI
FRFederico Righi
Federico Righi
GVGiulio Visentin
Giulio Visentin
MMMassimo De Marchi
Massimo De Marchi
The aim of the present study was to investigate the ability of a handheld near-infrared spectrometer to predict total and gelatinized starch, insoluble fibrous fractions, and mineral content in extruded dry dog food. Intact and ground samples were compared to determine if the homogenization could improve the prediction performance of the instrument. Reference analyses were performed on 81 samples for starch and 99 for neutral detergent fiber (NDF), acid detergent fiber (ADF), acid detergent lignin (ADL), and minerals, and reflectance infrared spectra (740 to 1070 nm) were recorded with a SCiO™ near-infrared (NIR) spectrometer. Prediction models were developed using modified partial least squares regression and both internal (leave-one-out cross-validation) and external validation. The best prediction models in cross-validation using ground samples were obtained for gelatinized starch (residual predictive deviation, RPD = 2.54) and total starch (RPD = 2.33), and S (RPD = 1.92), while the best using intact samples were obtained for gelatinized starch (RPD = 2.45), total starch (RPD = 2.08), and K (RPD = 1.98). Through external validation, the best statistics were obtained for gelatinized starch, with an RPD of 2.55 and 2.03 in ground and intact samples, respectively. Overall, there was no difference in prediction models accuracy using ground or intact samples. In conclusion, the miniaturized NIR instrument offers the potential for screening purposes only for total and gelatinized starch, S, and K, whereas the results do not support its applicability for the other traits.

1 January 2021 in Italian Journal of Animal Science
Verified
Journal Article
Open access
MSMARICA SIMONI
MARICA SIMONI
AGArianna Goi
Arianna Goi
MMMassimo De Marchi
Massimo De Marchi
FRFederico Righi
Federico Righi
Data about diet and digestion process of cattle are important for the fine-tuning of the diet and from an environmental point of view. Given the capacity of the near-infrared reflectance spectroscopy (NIRS) to provide easily, quickly and cheap data its ability in predicting dietary and faecal chemical composition, fibre-bound N and total-tract apparent digestibility (ttaD) of beef cattle were tested. The ttaD was estimated using the dietary and faecal undigestible neutral detergent fibre (uNDF) as an internal marker. A total of 172 pool faecal samples and 164 total mixed ration (TMR) samples were randomly collected 24 h post-feeding across the fattening groups of young males and females Charolaise beef cattle. Both TMR and faeces were analysed chemically and through visible/NIRS instrument. Calibration models were developed using a modified partial least squares (mPLS) regression analysis and tested by a leave-one-out cross-validation procedure and the best calibrations were selected based on various parameters including the coefficient of determination of calibration (R2CrV) and the residual predictive deviation (RPD). The overall composition of TMR and faeces were similar to that reported in literature and the coefficient of variation was higher than 12% for most of the parameters studied. The NIRS was able to accurately predict the ADF, nitrogen (N), and ash content in the TMR, whereas in faeces only the ADF prediction was acceptable. The ttaD and total-tract true digestibility of N using the uNDF as an internal marker were inaccurately predicted both in TMR and in faeces (R2CrV ≤0.66; RPD ≤ 1.71).