wei-hua chen

wei-hua chen


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiaoheng Yan
Xiaoheng Yan
SHShangfei Huang
Shangfei Huang
Waldemar Tomasz SmolikWaldemar Tomasz Smolik
Waldemar Tomasz Smolik
WCwei-hua chen
wei-hua chen
SYSonghan Yang
Songhan Yang
Efficient electrical impedance imaging fault detection in grounding grid is necessary. In this paper, we propose an optimized differential-Multigrid-Homotopy algorithm for grounding grid impedance imaging. To enhance the iteration speed, we introduced an optimized differential algorithm to obtain the Jacobian matrix and derive calculation methods for the two-dimensional constraint operator and interpolation operator. Moreover, we utilize multigrid fast iteration and homotopy methods simultaneously to improve the rapidity and ill-posedness of the inverse problem. We validate the proposed algorithm through numerical simulations and experimental studies. First, we verify the time and convergence of the optimized differential algorithm for solving the Jacobian matrix. Secondly, we investigate the CPU time and convergence of image reconstruction based on the Tikhonov algorithm, HT algorithm, and Multigrid-Homotopy (MG-HT) algorithm under different ground grid fault scenarios and noise levels. The simulation and experimental results show that the optimized differential-Multigrid-Homotopy algorithm has better robustness and convergence.

1 June 2023 in CES Transactions on Electrical Machines and Systems
Verified
Journal Article
Closed access
WCwei-hua chen
wei-hua chen
SWShuai Wang
Shuai Wang
XYXiaoheng Yan
Xiaoheng Yan
ZYZhiquan Ye
Zhiquan Ye
Magnetically coupled resonant technology is a novel method for solving the breakpoint locating of power grounding grid. But the method can only detect breakpoints of a single mesh grounding grid at present. In this paper, a magnetically coupled resonant detection method for four-hole grounding grid breakpoint is proposed. Firstly, the equivalent circuit model of the four mesh grounding grid with two types of breakpoints, namely edge branch and intermediate branch, is established. The input impedance and phase angle of the system are obtained by analyzing the equivalent capacitance and equivalent resistance in the model. Secondly, the magnetically coupled resonant physical process of grounding grid faults is solved via HFSS software. The magnetic field intensity and phase frequency characteristic curves of four mesh holes with different branches and positions of breakpoints and different corrosion degrees are studied, and an experimental system is built to verify the feasibility. The results show that under the condition of grounding grid buried depth of 0.5 m and input frequency of 1∼15MHz, and there is an inverse relationship between equivalent capacitance and distortion frequency, the phase angle is positively correlated with the degree of corrosion of grounding grid, and the error of signal distortion frequency can be positioned at 5%. This paper provides some ideas for the application of magnetic coupling grounding grid detection technology.

9 October 2021 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
XYXiaoheng Yan
Xiaoheng Yan
YHYu Hu
Yu Hu
SGSichen Guang
Sichen Guang
WCwei-hua chen
wei-hua chen

1 February 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WHWeiyi Huang
Weiyi Huang
XYXiaoheng Yan
Xiaoheng Yan
WCwei-hua chen
wei-hua chen
FZFeiyu Zhu
Feiyu Zhu
YYYugang Yang
Yugang Yang
Yun ZhangYun Zhang
Yun Zhang

21 April 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
WCwei-hua chen
wei-hua chen
CWChao Wang
Chao Wang
XYXiaoheng Yan
Xiaoheng Yan
FZFeiyu Zhu
Feiyu Zhu
In response to the issues of low transmission efficiency, poor offset tolerance, and severe magnetic leakage in wireless energy transmission systems for cardiac pacemakers, this paper presents a novel wireless power transfer system for cardiac pacemakers based on Multi- magnetic negative materials(Multi-MNG). Based on the theory of equivalent medium for magnetic negative materials (MNG) and the distribution of magnetic fields, three different metamaterial units with varying magnetic permeabilities are designed and arranged in a mixed manner to ensure effective convergence of the system's magnetic field, shield magnetic field leakage, and reduce Specific Absorption Rate (SAR). The accuracy, high efficiency, robustness, and safety of the Multi-MNG system's transmission are validated through simulations at 8.94MHz, and it mitigates the impact of magnetic leakage on the human body without a significant decrease in transmission performance. The maximum SAR value of the system is 0.0000504. The transmission performance of the Multi-MNG system is compared with that of ferrite, an unshielded MNG array 1 system, and a traditional system. The experiment unequivocally verifies the high performance of the Multi-MNG system, with a demonstrated maximum system output power of 1.323W and a transmission efficiency peaking at 72.1%, The temperature rise is 2.9°C, which meets human safety standards.

1 January 2019 in Progress in Electromagnetics Research C
Verified
Journal Article
Open access
PDF file
XYXiaoheng Yan
Xiaoheng Yan
FLFuyu Ling
Fuyu Ling
WCwei-hua chen
wei-hua chen
MCMingchen Cai
Mingchen Cai
When an implantable medical device is in radio energy transmission, due to eddy current effect, the temperature of the device will rise, causing a safety risk. In order to study the distribution law of its temperature field, this paper adopts the analysis method of electromagnetic-thermal-fluid-solid multi-physics coupling, and establishes a two-dimensional transient equivalent model of an implantable medical device radio energy transmission system, adopting the analysis method of the electromagneticthermal-fluid-solid multi-field full coupling. Among these, electromagnetic heat is applied as the heat source, considering the influence of factors, such as heat conduction and convection. By means of simulated calculation, this paper acquired one-dimensional, two-dimensional and three-dimensional images ,whose temperature and efficiency changed with frequency. Moreover, their distribution laws are also obtained. In order to verify the correctness of the simulation, this paper conducts infrared temperature measurement experiments to prove the rationality of the analysis through comparing the simulation results. The research findings of this paper can provide a basis for the design of a radio energy transmission system for an implantable medical device, improve the safety of implantable medical devices, and reduce the occurrence of medical accidents. Meanwhile, it has certain reference value to the clinical application of implantable medical devices.