Feiyu Zhu

Feiyu Zhu

Auto-generated profile, based on publicly available information

Feiyu Zhu

Faculty of Electrical and Control Engineering Liaoning Technical University Huludao City China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WHWeiyi Huang
Weiyi Huang
XYXiaoheng Yan
Xiaoheng Yan
WCwei-hua chen
wei-hua chen
FZFeiyu Zhu
Feiyu Zhu
YYYugang Yang
Yugang Yang
Yun ZhangYun Zhang
Yun Zhang

21 April 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
WCwei-hua chen
wei-hua chen
CWChao Wang
Chao Wang
XYXiaoheng Yan
Xiaoheng Yan
FZFeiyu Zhu
Feiyu Zhu
In response to the issues of low transmission efficiency, poor offset tolerance, and severe magnetic leakage in wireless energy transmission systems for cardiac pacemakers, this paper presents a novel wireless power transfer system for cardiac pacemakers based on Multi- magnetic negative materials(Multi-MNG). Based on the theory of equivalent medium for magnetic negative materials (MNG) and the distribution of magnetic fields, three different metamaterial units with varying magnetic permeabilities are designed and arranged in a mixed manner to ensure effective convergence of the system's magnetic field, shield magnetic field leakage, and reduce Specific Absorption Rate (SAR). The accuracy, high efficiency, robustness, and safety of the Multi-MNG system's transmission are validated through simulations at 8.94MHz, and it mitigates the impact of magnetic leakage on the human body without a significant decrease in transmission performance. The maximum SAR value of the system is 0.0000504. The transmission performance of the Multi-MNG system is compared with that of ferrite, an unshielded MNG array 1 system, and a traditional system. The experiment unequivocally verifies the high performance of the Multi-MNG system, with a demonstrated maximum system output power of 1.323W and a transmission efficiency peaking at 72.1%, The temperature rise is 2.9°C, which meets human safety standards.

22 November 2024 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
SGSouleiman Hassan Guirreh
Souleiman Hassan Guirreh
FZFeiyu Zhu
Feiyu Zhu
WCWeihua Chen
Weihua Chen
JPJishen Peng
Jishen Peng

1 January 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FZFeiyu Zhu
Feiyu Zhu
XYXiaoheng Yan
Xiaoheng Yan
WHWeiyi Huang
Weiyi Huang
WCWeihua Chen
Weihua Chen
JMJunqiang Ma
Junqiang Ma

4 February 2026 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
WCWeihua Chen
Weihua Chen
JWJianjun Wang
Jianjun Wang
XYXiaoheng Yan
Xiaoheng Yan
YSYu Shan
Yu Shan
FZFeiyu Zhu
Feiyu Zhu

22 March 2026 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
WCWeihua Chen
Weihua Chen
ZHZhishi Huang
Zhishi Huang
XYXiaoheng Yan
Xiaoheng Yan
WHWeiyi Huang
Weiyi Huang
FZFeiyu Zhu
Feiyu Zhu