High performance concrete (HPC) is a high strength concrete that undergoes a lot of early-age autogenous shrinkage (AS). If shrinkage is restrained, then micro-cracks arise and threaten the durability of the structure. Superabsorbent polymers (SAPs) can reduce/mitigate the autogenous shrinkage, due to their promising application as internal curing agents. In this paper, large-scale demonstrators were built to investigate the efficiency of SAPs to mitigate autogenous shrinkage in HPC. For this purpose, different measurement techniques were used like embedded fiber optic sensors and demountable mechanical strain gauges, complemented by AS measurements in corrugated tubes and restrained ring tests. The SAP wall showed an AS reduction of 22%, 54%, and 60% at the bottom, middle, and top, respectively, as recorded by the sensors (in comparison with the reference wall (REF)). In the corrugated tubes, mitigation of AS was shown in the SAP mixture, and under restrained conditions, in the ring test, the reference mixture cracked after two days, while the SAP mixture had not cracked at the end of the measurement period (20 days). Cracks were shown on REF wall after one day, while the SAP wall was crack-free. Water flow tests performed on the main crack of the REF wall confirmed that the flow rate is related to the third power of the crack width. All tests showed that SAPs could highly reduce AS in HPC and avoid cracking.
Many studies have already been published concerning autogenous shrinkage in cementitious materials. Still, no consensus can be found in the literature regarding the determination of the time-zero to initiate the recording of autogenous shrinkage. With internal curing agents, a correct evaluation of their efficiency depends on an appropriate choice of the time-zero. This study investigates different approaches to estimate the time-zero for cement paste mixtures with and without superabsorbent polymers as internal curing agents. The initial and final setting times were determined by an electronic Vicat and ultrasonic pulse velocity measurements (UPV); the transition point between the fluid and solid state was determined from the autogenous strain curve; the development of the capillary pressure was also studied. The choice of time-zero before the transition point led to higher values of shrinkage strain that should not be taken into account for autogenous shrinkage. A negligible difference was found between the strains when the final setting time and the transition point were taken as time-zero. Considering the artefacts and practical issues involving the different methods, the use of the transition point from the autogenous strain curve is the most suitable technique for determining the time-zero.
Modern infrastructure heavily relies on robust concrete structures, underscoring the critical need for effective monitoring to ensure their safety and durability. This paper addresses this imperative issue by introducing an innovative automated and wireless system for continuous structural monitoring. By employing embedded electrical resistivity sensors coupled with a wireless-based data transmission mechanism, real-time data collection becomes feasible. We provide a general description of the system’s architecture and its application in a pilot study covering the effects of the devices on concrete properties and data transmission. The dielectric properties of concrete specimens were investigated under natural and accelerated curing/degradation and the results were used in the final design of the antenna device. Furthermore, a pilot test comprising four reinforced concrete columns was used to investigate the range of data transmission from inside to outside of the concrete, the effects of the hardware device on the compressive strength and concrete distribution in the columns, and the data transmission quality in real time under realistic exposure conditions.