Adam Tomaszewski

Dr. Adam Tomaszewski

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
PRPaulina Rolka
Paulina Rolka
RKRoman Kwidzinski
Roman Kwidzinski
TPTomasz Przybyliński
Tomasz Przybyliński
ATAdam Tomaszewski
Adam Tomaszewski
To reduce energy consumption and increase energy efficiency in the building sector, thermal energy storage with phase change materials (PCMs) is used. The knowledge of the thermophysical properties and the characteristics of PCMs (like their enthalpy changes and the distribution of stored energy over a specified temperature range) is essential for proper selection of the PCM and optimal design of the latent thermal energy store (LHTES). This paper presents experimental tests of the thermophysical properties of three medium-temperature PCMs: OM65, OM55, RT55, which can be used in domestic hot water installations and heating systems. Self-made test chambers with temperature control using Peltier cells were used to perform measurements according to the T-history method. In this way the temperature range of the phase transition, latent heat, specific heat capacity, enthalpy and the distributions of stored energy of the three PCMs were determined. The paper also presents measurements of the thermal conductivity of these PCMs in liquid and solid state using a self-made pipe Poensgen apparatus. The presented experimental tests results are in good agreement with the manufacturers’ data and the results of other researchers obtained with the use of specialized instruments. The presented research results are intended to help designers in the selection of the right PCM for the future LHTES co-working with renewable energy systems, waste heat recovery systems and building heating systems.

18 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ATAdam Tomaszewski
Adam Tomaszewski
TPTomasz Przybyliński
Tomasz Przybyliński
MLMarcin Lackowski
Marcin Lackowski
The paper presents the results of the experimental and numerical analysis of a six-hole orifice flow meter. The experiments were performed on humid air in a 100 mm diameter duct. The aim of this research was to investigate the mass flow and pressure drop dependency in an orifice of a predetermined shape and to compare the results obtained with computational formulas recommended in the ISO 5167-2 standard for a single-hole orifice flow meter. The experiments and calculations were performed on several multi-hole orifice geometries with different contraction coefficient in a wide range of Reynolds numbers. The pressure was probed immediately upstream and downstream of the orifice. The flow coefficient determined for the six-hole orifice flow meter investigated was compared with the flow coefficient of conventional single-hole orifice with the same contraction coefficient. The results from computational formulas for single-hole orifice from ISO 5167 are also included in the paper. During some experiments, an obstacle has been introduced in the duct at variable distance upstream from the orifice. The effect of the thus generated velocity field disturbance on the measured pressure drop was then investigated. Numerical simulation of the flow with the presence of the obstacle was also performed and compared with experimental data.

20 January 2023 in Fire
Verified
Journal Article
Open access
PDF file
SSSeweryn Szultka
Seweryn Szultka
Stanislaw CzappStanislaw Czapp
Stanislaw Czapp
ATAdam Tomaszewski
Adam Tomaszewski
HUHayat Ullah
Hayat Ullah
Evaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum permissible temperature in unfavorable ambient conditions. Overheated and damaged cable insulation can be a source of electric shock and a strong leakage current causing fire. In the case of typical PV connectors (MC4 connectors), the main problem is poor contact at the connections of the PV cables. A poor connection can even cause the connector to melt, as shown in this study. In the paper, the authors present a computer simulation regarding critical thermal points of electrical installations, in particular, of the PV type. It may be an indication of what should be paid attention to when designing and implementing such installations. This is important for the safety of people and buildings.

30 June 2020 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
Stanislaw CzappStanislaw Czapp
Stanislaw Czapp
SSSeweryn Szultka
Seweryn Szultka
FRFilip Ratkowski
Filip Ratkowski
ATAdam Tomaszewski
Adam Tomaszewski
Low-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In some cases, the ampacity of power cables placed in free air is lower than in the ground. Differences in ampacities can be very high if thermal resistivity of the soil is very low, and simultaneously solar irradiation of cables in air occurs. This paper presents the risk of power cables overheating and in consequence the risk of their failure, when part of the underground power cable line is placed in free air. Temperature distribution of cables in the air (with and without solar radiation) for various load currents is presented. Thermal endurance of power cables insulation, operating with the overheating, is estimated.


22 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
Stanislaw CzappStanislaw Czapp
Stanislaw Czapp
SSSeweryn Szultka
Seweryn Szultka
ATAdam Tomaszewski
Adam Tomaszewski
Power cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying capacity of power cables—during exposure to direct solar radiation—are evaluated. An effective method of limiting the unfavourable impact of the sun is discussed. In the presence of solar radiation, the proposed method enables a significant increase in the power cables current-carrying capacity.