Nikita Nekrasov

Mr. Nikita Nekrasov

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
NNNikita Nekrasov
Nikita Nekrasov
SJStefan Jarić
Stefan Jarić
Dmitry KireevDmitry Kireev
Dmitry Kireev
AEAleksei Emelianov
Aleksei Emelianov
AOAlexey V. Orlov
Alexey V. Orlov
IBIvan Bobrinetskiy
Ivan Bobrinetskiy

20 September 2019 in Toxins
Verified
Journal Article
Open access
PDF file
NNNikita Nekrasov
Nikita Nekrasov
Dmitry KireevDmitry Kireev
Dmitry Kireev
AEAleksei Emelianov
Aleksei Emelianov
IBIvan Bobrinetskiy
Ivan Bobrinetskiy
In this work, we report an on-chip aptasensor for ochratoxin A (OTA) toxin detection that is based on a graphene field-effect transistor (GFET). Graphene-based devices are fabricated via large-scale technology, allowing for upscaling the sensor fabrication and lowering the device cost. The sensor assembly was performed through covalent bonding of graphene’s surface with an aptamer specifically sensitive towards OTA. The results demonstrate fast (within 5 min) response to OTA exposure with a linear range of detection between 4 ng/mL and 10 pg/mL, with a detection limit of 4 pg/mL. The regeneration time constant of the sensor was found to be rather small, only 5.6 s, meaning fast sensor regeneration for multiple usages. The high reproducibility of the sensing response was demonstrated via using several recycling procedures as well as various GFETs. The applicability of the aptasensor to real samples was demonstrated for spiked red wine samples with recovery of about 105% for a 100 pM OTA concentration; the selectivity of the sensor was also confirmed via addition of another toxin, zearalenone. The developed platform opens the way for multiplex sensing of different toxins using an on-chip array of graphene sensors.

10 November 2023 in Microchemical Journal
Verified
Journal Article
Closed access
SJStefan Jarić
Stefan Jarić
АКАнастасия Кудрявцева
Анастасия Кудрявцева
NNNikita Nekrasov
Nikita Nekrasov
AOAlexey Orlov
Alexey Orlov
IKIvan Alexandrovich Komarov
Ivan Alexandrovich Komarov
IBIvan Bobrinetskiy
Ivan Bobrinetskiy

16 January 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
NNNikita Nekrasov
Nikita Nekrasov
NYNatalya Yakunina
Natalya Yakunina
APAveryan V. Pushkarev
Averyan V. Pushkarev
AOAlexey Orlov
Alexey Orlov
IGIvana Gadjanski
Ivana Gadjanski
IBIvan Bobrinetskiy
Ivan Bobrinetskiy
In this work, we report a novel method of label-free detection of small molecules based on direct observation of interferometric signal change in graphene-modified glasses. The interferometric sensor chips are fabricated via a conventional wet transfer method of CVD-grown graphene onto the glass coverslips, lowering the device cost and allowing for upscaling the sensor fabrication. For the first time, we report the use of graphene functionalized by the aptamer as the bioreceptor, in conjunction with Spectral-Phase Interferometry (SPI) for detection of ochratoxin A (OTA). In a direct assay with an OTA-specific aptamer, we demonstrated a quick and significant change of the optical signal in response to the maximum tolerable level of OTA concentration. The sensor regeneration is possible in urea solution. The developed platform enables a direct method of kinetic analysis of small molecules using a low-cost optical chip with a graphene-aptamer sensing layer.

23 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
NNNikita Nekrasov
Nikita Nekrasov
АКАнастасия Кудрявцева
Анастасия Кудрявцева
AOAlexey Orlov
Alexey Orlov
IGIvana Gadjanski
Ivana Gadjanski
MNMaxim Nikitin
Maxim Nikitin
Nikola KneževićNikola Knežević
Nikola Knežević
A novel photochemical technological route for one-step functionalization of a graphene surface with an azide-modified DNA aptamer for biomarkers is developed. The methodology is demonstrated for the functionalization of a DNA aptamer for an N-terminal B-type natriuretic peptide (NT-proBNP) heart failure biomarker on the surface of a graphene channel within a system based on a liquid-gated graphene field effect transistor (GFET). The limit of detection (LOD) of the aptamer-functionalized sensor is 0.01 pg/mL with short response time (75 s) for clinically relevant concentrations of the cardiac biomarker, which could be of relevance for point-of-care (POC) applications. The novel methodology could be applicable for the development of different graphene-based biosensors for fast, stable, real-time, and highly sensitive detection of disease markers.

26 April 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
АКАнастасия Кудрявцева
Анастасия Кудрявцева
SJStefan Jarić
Stefan Jarić
NNNikita Nekrasov
Nikita Nekrasov
AOAlexey Orlov
Alexey Orlov
IGIvana Gadjanski
Ivana Gadjanski
Nikola KneževićNikola Knežević
Nikola Knežević
Graphene-based materials are actively being investigated as sensing elements for the detection of different analytes. Both graphene grown by chemical vapor deposition (CVD) and graphene oxide (GO) produced by the modified Hummers’ method are actively used in the development of biosensors. The production costs of CVD graphene- and GO-based sensors are similar; however, the question remains regarding the most efficient graphene-based material for the construction of point-of-care diagnostic devices. To this end, in this work, we compare CVD graphene aptasensors with the aptasensors based on reduced GO (rGO) for their capabilities in the detection of NT-proBNP, which serves as the gold standard biomarker for heart failure. Both types of aptasensors were developed using commercial gold interdigitated electrodes (IDEs) with either CVD graphene or GO formed on top as a channel of liquid-gated field-effect transistor (FET), yielding GFET and rGO-FET sensors, respectively. The functional properties of the two types of aptasensors were compared. Both demonstrate good dynamic range from 10 fg/mL to 100 pg/mL. The limit of detection for NT-proBNP in artificial saliva was 100 fg/mL and 1 pg/mL for rGO-FET- and GFET-based aptasensors, respectively. While CVD GFET demonstrates less variations in parameters, higher sensitivity was demonstrated by the rGO-FET due to its higher roughness and larger bandgap. The demonstrated low cost and scalability of technology for both types of graphene-based aptasensors may be applicable for the development of different graphene-based biosensors for rapid, stable, on-site, and highly sensitive detection of diverse biochemical markers.