Ioannis Kandarakis

Prof. Dr. Ioannis Kandarakis


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2020 in Crystals
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
VKVaia Koukou
Vaia Koukou
NMNiki Martini
Niki Martini
GSGeorge Saatsakis
George Saatsakis
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis ValaisIoannis Valais
Ioannis Valais
Background: In this study, the light output of a cadmium tungstate (CdWO4) single crystal was measured under various X-ray radiographic energies. Methods: A CdWO4 single crystal (10 × 10 × 10 mm3) was exposed to X-rays in the 50–130 kVp range. Measurements were evaluated against published data for single crystals of equal dimensions (CaF2:Eu and Lu3Al5O12:Ce). Since the crystal was examined for application in medical imaging detectors, the emitted optical spectrum was classified with respect to the spectral compatibility of numerous commercial optical sensors. Results: The luminescence efficiency (LE) was found to constantly increase with X-ray energy and was higher than that of CaF2:Eu for energies above 90 kVp. However, the efficiency of the previously published Lu3Al5O12:Ce was found to be constantly higher than that of CdWO4. The light emitted from CdWO4 can be optimally detected by certain charge-coupled devices (CCDs), amorphous silicon photodiodes, and photocathodes. Conclusions: The high density (7.9 g/cm3) of CdWO4 and the luminescence signal of this material make it suitable for medical imaging (such as dual energy), high-energy physics or for applications of scintillators in harsh environments.

7 February 2024 in Crystals
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
PLPanagiotis Liaparinos
Panagiotis Liaparinos
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis KandarakisIoannis Kandarakis
Ioannis Kandarakis
George FountosGeorge Fountos
George Fountos
Ioannis ValaisIoannis Valais
Ioannis Valais
Medical imaging instrumentation is mostly based on the use of luminescent materials coupled to optical sensors. These materials are employed in the form of granular screens, structured crystals, single transparent crystals, ceramics, etc. Storage phosphors are also incorporated in particular X-ray imaging systems. The physical properties of these materials should match the criteria required by the detective systems employed in morphological and functional biomedical imaging. The systems are analyzed based on theoretical frameworks emanating from the linear cascaded systems theory as well as the signal detection theory. Optical diffusion has been studied by different methodological approaches, such as experimental measurements and analytical modeling, including geometrical optics and Monte Carlo simulation. Analysis of detector imaging performance is based on image quality metrics, such as the luminescence emission efficiency (LE), the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE). Scintillators and phosphors may present total energy conversion on the order of 0.001–0.013 with corresponding DQE in the range of 0.1–0.6. Thus, the signal-to-noise ratio, which is crucial for medical diagnosis, shows clearly higher values than those of the energy conversion.

26 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
PLPanagiotis Liaparinos
Panagiotis Liaparinos
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis KandarakisIoannis Kandarakis
Ioannis Kandarakis
George FountosGeorge Fountos
George Fountos
Ioannis ValaisIoannis Valais
Ioannis Valais
Medical imaging instrumentation design and construction is based on radiation sources and radiation detectors/sensors. This review focuses on the detectors and sensors of medical imaging systems. These systems are subdivided into various categories depending on their structure, the type of radiation they capture, how the radiation is measured, how the images are formed, and the medical goals they serve. Related to medical goals, detectors fall into two major areas: (i) anatomical imaging, which mainly concerns the techniques of diagnostic radiology, and (ii) functional-molecular imaging, which mainly concerns nuclear medicine. An important parameter in the evaluation of the detectors is the combination of the quality of the diagnostic result they offer and the burden of the patient with radiation dose. The latter has to be minimized; thus, the input signal (radiation photon flux) must be kept at low levels. For this reason, the detective quantum efficiency (DQE), expressing signal-to-noise ratio transfer through an imaging system, is of primary importance. In diagnostic radiology, image quality is better than in nuclear medicine; however, in most cases, the dose is higher. On the other hand, nuclear medicine focuses on the detection of functional findings and not on the accurate spatial determination of anatomical data. Detectors are integrated into projection or tomographic imaging systems and are based on the use of scintillators with optical sensors, photoconductors, or semiconductors. Analysis and modeling of such systems can be performed employing theoretical models developed in the framework of cascaded linear systems analysis (LCSA), as well as within the signal detection theory (SDT) and information theory.

1 May 2019 in Crystals
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
NKNektarios Kalyvas
Nektarios Kalyvas
ABATHANASIOS Dimitrios BAKAS
ATHANASIOS Dimitrios BAKAS
KNKonstantinos Ninos
Konstantinos Ninos
ISIoannis Sianoudis
Ioannis Sianoudis
Ioannis ValaisIoannis Valais
Ioannis Valais
The absolute luminescence efficiency (AE) of a calcium fluoride (CaF2:Eu) single crystal doped with europium was studied using X-ray energies met in general radiography. A CaF2:Eu single crystal with dimensions of 10 × 10 × 10 mm3 was irradiated by X-rays. The emission light photon intensity of the CaF2:Eu sample was evaluated by measuring AE within the X-ray range from 50 to 130 kV. The results of this work were compared with data obtained under similar conditions for the commercially employed medical imaging modalities, Bi4Ge3O12 and Lu2SiO5:Ce single crystals. The compatibility of the light emitted by the CaF2:Eu crystal, with the sensitivity of optical sensors, was also examined. The AE of the 10 × 10 × 10 mm3 CaF2:Eu crystal peaked in the range from 70 to 90 kV (22.22 efficiency units; E.U). The light emitted from CaF2:Eu is compatible with photocathodes, charge coupled devices (CCD), and silicon photomultipliers, which are used as radiation sensors in medical imaging systems. Considering the AE results in the examined energies, as well as the spectral compatibility with various photodetectors, a CaF2:Eu single crystal could be considered for radiographic applications, including the detection of charged particles and soft gamma rays.

13 July 2015 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
VKV. Koukou
V. Koukou
NMN. Martini
N. Martini
Christos MichailChristos Michail
Christos Michail
PSP. Sotiropoulou
P. Sotiropoulou
CFC. Fountzoula
C. Fountzoula
George FountosGeorge Fountos
George Fountos
Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNRtc) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.

4 July 2019 in Crystals
Verified
Journal Article
Open access
PDF file
GSGeorge Saatsakis
George Saatsakis
NKNektarios Kalyvas
Nektarios Kalyvas
Christos MichailChristos Michail
Christos Michail
KNKonstantinos Ninos
Konstantinos Ninos
ABATHANASIOS Dimitrios BAKAS
ATHANASIOS Dimitrios BAKAS
GPGeorge Panayiotakis
George Panayiotakis
The aim of this article is to evaluate optical characteristics, such as the intrinsic conversion efficiency and the inherent light propagation efficiency of three polymethyl methacrylate (PMMA)/methyl methacrylate (MMA) composite ZnCuInS/ZnS (core/shell) nanocrystal flexible films. The concentrations of these were 100 mg/mL, 150 mg/mL, and 250 mg/mL, respectively. Composite films were prepared by homogeneously diluting dry powder quantum dot (QD) samples in toluene and subsequently mixing these with a PMMA/MMA polymer solution. The absolute luminescence efficiency (AE) of the films was measured using X-ray excitation. A theoretical model describing the optical photon propagation in scintillator materials was used to calculate the fraction of the generated optical photons passed through the different material layers. Finally, the intrinsic conversion efficiency was calculated by considering the QD quantum yield and the optical photon emission spectrum.