Hyun Young Choi

Prof. Hyun Young Choi

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BKBongyoung Kim
Bongyoung Kim
HCHyun Young Choi
Hyun Young Choi
WKWonhee Kim
Wonhee Kim
Chiwon AhnChiwon Ahn
Chiwon Ahn
JLJuncheol Lee
Juncheol Lee
SMShinje Moon
Shinje Moon
The current methods available for determining insulin resistance are complicated; hence, they are only applicable to small-scale studies. Therefore, this study aimed to classify the characteristics of surrogate measures for insulin resistance and establish valid cut-off values for predicting the development of type 2 diabetes mellitus (DM) in Korean populations. This prospective study included 7,643 participants aged 40–69 years from the Ansung-Ansan cohort database (2001–2012). Four surrogate measures, namely homeostasis model assessment-insulin resistance (HOMA-IR), visceral adiposity index (VAI), lipid accumulation product (LAP), and triglycerides and glucose (TyG) index, were analyzed. We analyzed each measure using receiver operating characteristic (ROC) curve for the development of type 2 DM. The cut-off value was determined as the value with the highest Youden index score in the specificity dominant area. The area under the curve (AUC) was 0.566 (95% confidence interval [CI], 0.548–0.583) for HOMA-IR, 0.622 (95% CI, 0.605–0.639) for VAI, 0.642 (95% CI, 0.625–0.658) for LAP, and 0.672 (95% CI, 0.656–0.687) for TyG index. The AUC of TyG index was significantly higher than that of HOMA-IR, VAI, and LAP (p < 0.001). The cut-off value was 2.54 (sensitivity 36.8%; specificity 73.1%; hazard ratio [HR], 1.41, 95% CI, 1.25–1.59) for HOMA-IR, 2.54 (sensitivity 50.4%; specificity 68.8%; HR, 1.75, 95% CI, 1.55–1.96) for VAI, 36.6 (sensitivity 59.2%; specificity 63.9%; HR, 1.87, 95% CI, 1.64–2.14) for LAP, and 4.69 (sensitivity 62.1%; specificity 63.1%; HR, 2.17, 95% CI, 1.92–2.45) for TyG index. The TyG index was a better predictor for DM than HOMA-IR. VAI and LAP showed the modest predictability for DM. The TyG index could be a useful supplementary method for identifying individuals at risk for insulin resistance and DM development.

24 January 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YLYoonje Lee
Yoonje Lee
YKYu-Seop Kim
Yu-Seop Kim
DLDAIN LEE
DAIN LEE
SJSeri Jeong
Seri Jeong
GKGu-Hyun Kang
Gu-Hyun Kang
SCSang-Hoon Choi
Sang-Hoon Choi
Reducing the time to diagnose COVID-19 helps to manage insufficient isolation-bed resources and adequately accommodate critically ill patients. There is currently no alternative method to real-time reverse transcriptase polymerase chain reaction (RT-PCR), which requires 40 cycles to diagnose COVID-19. We propose a deep learning (DL) model to improve the speed of COVID-19 RT-PCR diagnosis. We developed and tested a DL model using the long short-term memory method with a dataset of fluorescence values measured in each cycle of 5810 RT-PCR tests. Among the DL models developed here, the diagnostic performance of the 21st model showed an area under the receiver operating characteristic (AUROC), sensitivity, and specificity of 84.55%, 93.33%, and 75.72%, respectively. The diagnostic performance of the 24th model showed an AUROC, sensitivity, and specificity of 91.27%, 90.00%, and 92.54%, respectively.

24 June 2016 in Journal of Molecular Neuroscience
Verified
Journal Article
Closed access
PDF file
JPJoon Ha Park
Joon Ha Park
HCHyun Young Choi
Hyun Young Choi
JCJeong-Hwi Cho
Jeong-Hwi Cho
IKIn Hye Kim
In Hye Kim
TLTae-Kyeong Lee
Tae-Kyeong Lee
JKJongDai Kim
JongDai Kim

21 May 2016 in Neurochemical Research
Verified
Journal Article
Closed access
PDF file
HCHyun Young Choi
Hyun Young Choi
JPJoon Ha Park
Joon Ha Park
BCBai Hui Chen
Bai Hui Chen
BSBich Na Shin
Bich Na Shin
YLYun Lyul Lee
Yun Lyul Lee
SKSung Koo Kim
Sung Koo Kim

16 June 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
HCHyun Young Choi
Hyun Young Choi
YOYoung Min Oh
Young Min Oh
GKGu Hyun Kang
Gu Hyun Kang
HKHyunggoo Kang
Hyunggoo Kang
YJYong Soo Jang
Yong Soo Jang
GKGyoung Yong Kim
Gyoung Yong Kim
Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.

30 June 2016 in Clinical and Experimental Emergency Medicine
Verified
Journal Article
Open access
PDF file
YKYoung Yong Kim
Young Yong Kim
GKGu Hyun Kang
Gu Hyun Kang
WKWon Hee Kim
Won Hee Kim
HCHyun Young Choi
Hyun Young Choi
YJYong Soo Jang
Yong Soo Jang
GKGyoung Yong Kim
Gyoung Yong Kim
This study aimed to compare intubation performance between blind intubation through supraglottic airway devices and direct laryngoscopy by novices under manikin simulation. We hypothesized that the intubation time by novices using supraglottic airway devices was superior to that with the Macintosh laryngoscope (MCL). A prospective, randomized crossover study was conducted with 95 participants, to evaluate i-gel, air-Q, LMA Fastrach, and MCL devices. Primary outcomes were the intubation time and the success rate for intubation. The i-gel showed the shortest insertion and tube passing time among the four devices; the i-gel and air-Q also showed the shortest total intubation time (all P<0.0083; i-gel vs. air-Q, P=0.03). The i-gel and MCL showed the highest cumulative success rate (all P<0.0083; i-gel vs. MCL, P=0.12). Blind intubation through the i-gel showed almost equal intubation performance compared to direct laryngoscopy.