This study aims to help professionals in the field of running and running-related technology (i.e., sports watches and smartphone applications) to address the needs of runners. It investigates the various runner types—in terms of their attitudes, interests, and opinions (AIOs) with regard to running—and studies how they differ in the technology they use. Data used in this study were drawn from the standardized online Eindhoven Running Survey 2016 (ERS2016). In total, 3723 participants completed the questionnaire. Principal component analysis and cluster analysis were used to identify the different running types, and crosstabs obtained insights into the use of technology between different typologies. Based on the AIOs, four distinct runner types were identified: casual individual, social competitive, individual competitive, and devoted runners. Subsequently, we related the types to their use of sports watches and apps. Our results show a difference in the kinds of technology used by different runner types. Differentiation between types of runners can be useful for health professionals, policymakers involved in public health, engineers, and trainers or coaches to adapt their services to specific segments, in order to make use of the full potential of running-related systems to support runners to stay active and injury-free and contribute to a healthy lifestyle.
Living labs are an extremely attractive open innovation landscape for collaborative research and development activities targeting the complexity of today’s societal challenges. However, although there is plenty of support for collaboration, we still lack clear guidelines to direct transdisciplinary stakeholder networks of academics and practitioners through collaboration processes in the living lab ecosystem. In other words, we lack answers to the question of “how to collaborate?” In the present paper we propose a conceptual framework defining relevant stages to initiate and facilitate transdisciplinary collaboration processes. We base our framework on collaboration challenges described in the literature, specifically the need for stakeholder alignment, as well as challenges experienced in practice, which we report through exploratory case studies. In the proposed conceptual framework, we advocate the application of co-creation methods, both at the level of the living lab (macro) and in projects (meso) within the living lab, in order to define, with all involved parties and stakeholders, the scope and strategy of the living lab and to facilitate stakeholder alignment. Additionally, we integrate an iterative approach and a feedback loop in order to account for the dynamic nature of the collaboration process and to enable reflection and evaluation.
Background: There is increasing interest in the role that technology can play in improving the vitality of knowledge workers. A promising and widely adopted strategy to attain this goal is to reduce sedentary behavior (SB) and increase physical activity (PA). In this paper, we review the state-of-the-art SB and PA interventions using technology in the office environment. By scoping the existing landscape, we identified current gaps and underexplored possibilities. We discuss opportunities for future development and research on SB and PA interventions using technology. Methods: A systematic search was conducted in the Association for Computing Machinery digital library, the interdisciplinary library Scopus, and the Institute of Electrical and Electronics Engineers Xplore Digital Library to locate peer-reviewed scientific articles detailing SB and PA technology interventions in office environments between 2009 and 2019. Results: The initial search identified 1130 articles, of which 45 studies were included in the analysis. Our scoping review focused on the technologies supporting the interventions, which were coded using a grounded approach. Conclusion: Our findings showed that current SB and PA interventions using technology provide limited possibilities for physically active ways of working as opposed to the common strategy of prompting breaks. Interventions are also often offered as additional systems or services, rather than integrated into existing office infrastructures. With this work, we have mapped different types of interventions and provide an increased understanding of the opportunities for future multidisciplinary development and research of technologies to address sedentary behavior and physical activity in the office context.
Physical inactivity and chronic stress at work increase the risks of developing metabolic disorders, mental illnesses, and musculoskeletal injuries, threatening office workers’ physical and psychological well-being. Although several guidelines and interventions have been developed to prevent theses subhealth issues, their effectiveness and health benefits are largely limited when they cannot match workday contexts. This paper presents LightSit, a health-promoting system that helps people reduce physically inactive behaviors and manage chronic stress at work. LightSit comprises a sensor mat that can be embedded into an office chair for measuring a user’s sitting posture and heart rate variability and a lighting display that is integrated into a monitor stand to present information unobtrusively, facilitating fitness and relaxation exercises during microbreaks. Following the showroom approach, we evaluated LightSit during a public exhibition at Dutch Design Week 2018. During the eight days of the exhibition, we observed more than 500 sessions of experiences with healthy microbreaks using our prototype. Semistructured interviews were conducted with 50 participants who had office-based jobs and had experienced LightSit. Our qualitative findings indicated the potential benefits of LightSit in facilitating health-promoting behaviors during office work. Based on the insights learned from this study, we discuss the implications for future designs of interactive health-promoting systems.
Cardiovascular diseases (CVD) represent a serious health problem worldwide, of which atrial fibrillation (AF) is one of the most common conditions. Early and timely diagnosis of CVD is essential for successful treatment. When implemented in the healthcare system this can ease the existing socio-economic burden on health institutions and government. Therefore, developing technologies and tools to diagnose CVD in a timely way and detect AF is an important research topic. ECG monitoring patches allowing ambulatory patient monitoring over several days represent a novel technology, while we witness a significant proliferation of ECG monitoring patches on the market and in the research labs, their performance over a long period of time is not fully characterized. This paper analyzes the signal quality of ECG signals obtained using a single-lead ECG patch featuring self-adhesive dry electrode technology collected from six cardiac patients for 5 days. In particular, we provide insights into signal quality degradation over time, while changes in the average ECG quality per day were present, these changes were not statistically significant. It was observed that the quality was higher during the nights, confirming the link with motion artifacts. These results can improve CVD diagnosis and AF detection in real-world scenarios.
Background: There is growing evidence that physical activity is related to a better prognosis after a breast cancer diagnosis, whereas sedentary behavior is associated with worse outcomes. It is therefore important to stimulate physical activity and reduce sedentary time among patients with breast cancer. Activity trackers offer a new opportunity for interventions directed at stimulating physical activity behavior change. Objective: This study aimed to explore the experience of patients with breast cancer who used an activity tracker in addition to a supervised exercise intervention in the randomized UMBRELLA Fit trial. Methods: A total of 10 patients with breast cancer who completed cancer treatment participated in semistructured in-depth interviews about their experience with and suggestions for improvements for the Jawbone UP2 activity tracker. Results: The activity tracker motivated women to be physically active and created more awareness of their (sedentary) lifestyles. The women indicated that the automatically generated advice (received via the Jawbone UP app) lacked individualization and was not applicable to their personal situations (ie, having been treated for cancer). Furthermore, women felt that the daily step goal was one-dimensional, and they preferred to incorporate other physical activity goals. The activity tracker’s inability to measure strength exercises was a noted shortcoming. Finally, women valued personal feedback about the activity tracker from the physiotherapist. Conclusions: Wearing an activity tracker raised lifestyle awareness in patients with breast cancer. The women also reported additional needs not addressed by the system. Potential improvements include a more realistic total daily physical activity representation, personalized advice, and personalized goals.