Tao Yu

Dr. Tao Yu


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
BQBin Qian
Bin Qian
TYTao Yu
Tao Yu
HBHaiquan Bi
Haiquan Bi
BLBo Lei
Bo Lei
In recent years, the energy performance of public buildings has attracted substantial attention due to the significant energy-saving potential. As a semi-open high-space building, the high-speed railway station is obviously different from other public buildings and even traditional stations in terms of energy consumption and internal environment. This paper investigates the current energy consumption situation and environmental quality of 15 high-speed railway passenger stations in China. Results show that the energy consumption of the high-speed railway station is between 117–470 kWh/(m2·a). The energy consumption of the station is related to the area and the passenger flow. The energy use of the station using district heating is higher than that of the station without district heating in the same region. The higher glazing ratio induces good natural lighting in the station, but the uniformity of the lighting in the station is not good. The acceptable temperature range of passengers in winter is larger than that in summer. The average air change rate of the high-speed railway station is 3.2 h−1 in winter and 1.8 h−1 in summer, which is the main reason of high energy consumption of the HVAC (Heating Ventilation Air Conditioning) system in this kind of building.

23 April 2014 in Building Simulation
Verified
Journal Article
Closed access
PDF file
TYTao Yu
Tao Yu
Per HeiselbergPer Heiselberg
Per Heiselberg
BLBo Lei
Bo Lei
Michał PomianowskiMichał Pomianowski
Michał Pomianowski

24 January 2023 in Building Simulation
Verified
Journal Article
Closed access
PDF file
BQBin Qian
Bin Qian
TYTao Yu
Tao Yu
CZChen Zhang
Chen Zhang
PHPer Heiselberg
Per Heiselberg
BLBo Lei
Bo Lei
LYLi Yang
Li Yang

3 September 2022 in Building Simulation
Verified
Journal Article
Closed access
PDF file
JZJiacheng Zheng
Jiacheng Zheng
TYTao Yu
Tao Yu
BLBo Lei
Bo Lei
XLXiujing Luo
Xiujing Luo

1 March 2020 in Renewable Energy
Verified
Journal Article
Closed access
TYTao Yu
Tao Yu
JZJiangdong Zhao
Jiangdong Zhao
JZJiri Zhou
Jiri Zhou
BLBo Lei
Bo Lei

2 January 2023 in Indoor and Built Environment
Verified
Journal Article
Closed access
JZJiacheng Zheng
Jiacheng Zheng
TYTao Yu
Tao Yu
BLBo Lei
Bo Lei
CCChen Chen
Chen Chen
In some buildings with radiant floor systems for heating, solar radiation can irradiate the local floor surface, causing overheating and affecting the heating performance of the radiant floor. In this paper, an experiment was carried out to study the thermal performance of radiant floor partially irradiated by solar radiation. Results show that the solar radiation can promote the heat transfer from the irradiated floor to the room and reduce the heat transfer from the hot water to the floor. Compared with the cases without the solar radiation, the heat transfer from the hot water to the floor was reduced from 131.8 W/m2 to 79.7 W/m2 and the heating capacity of radiant floor surface was increased from 128.0 W/m2 to 402.8 W/m2 with the solar radiation on one third of the floor surface and the absorbed intensity of 456.2 W/m2. With the same irradiation area, if the solar radiation irradiated at the centre of the floor, the reduction effect on the heat transfer from the hot water was more obvious. Based on this experiment, these results can be used to evaluate the thermal performance of irradiated radiant floor, and are beneficial to the design of heating systems.