Eyad Radwan

Dr. Eyad Radwan

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
Bashar AldbaiatBashar Aldbaiat
Bashar Aldbaiat
Mutasim NourMutasim Nour
Mutasim Nour
EREyad Radwan
Eyad Radwan
Emad A. AwadaEmad A. Awada
Emad A. Awada
This paper presents a two-stage grid-connected PV system with reactive power management capability. The proposed model can send phase-shifted current to the grid during a low-voltage ride through (LVRT) to recover the voltage levels of the grid’s feeders. The novelty of the proposed algorithm, unlike the common methods, is that it does not need to disable the maximum power point tracking (MPPT) state while managing active and reactive power injection simultaneously. Moreover, the new method promotes a safety factor by offering overcurrent protection to the PV inverter. The phase-locked loop based on the synchronous reference frame (SRF-PLL) is optimized using a genetic algorithm (GA). The settling time of SRF-PLL’s step response is minimized, and the frequency dynamics are improved to enhance synchronization during LVRT. The system’s performance is tested and verified using MATLAB/Simulink simulations. The obtained results prove the effectiveness of the proposed control algorithm in managing reactive power interventions. The optimized phase-locked loop shows robust performance and is compared to the conventional low-gain PLL to spot the enhancement.

16 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
EREyad Radwan
Eyad Radwan
Mutasim NourMutasim Nour
Mutasim Nour
Emad A. AwadaEmad A. Awada
Emad A. Awada
ABAli Baniyounes
Ali Baniyounes
This paper presents a control scheme for a photovoltaic (PV) system that uses a single-phase grid-connected inverter with low-voltage ride-through (LVRT) capability. In this scheme, two PI regulators are used to adjust the power angle and voltage modulation index of the inverter; therefore, controlling the inverter’s active and reactive output power, respectively. A fuzzy logic controller (FLC) is also implemented to manage the inverter’s operation during the LVRT operation. The FLC adjusts (or de-rates) the inverter’s reference active and reactive power commands based on the grid voltage sag and the power available from the PV system. Therefore, the inverter operation has been divided into two modes: (i) Maximum power point tracking (MPPT) during the normal operating conditions of the grid, and (ii) LVRT support when the grid is operating under faulty conditions. In the LVRT mode, the de-rating of the inverter active output power allows for injection of some reactive power, hence providing voltage support to the grid and enhancing the utilization factor of the inverter’s capacity. The proposed system was modelled and simulated using MATLAB Simulink. The simulation results showed good system performance in response to changes in reference power command, and in adjusting the amount of active and reactive power injected into the grid.

1 October 2019 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
EREyad Radwan
Eyad Radwan
KSKhalil Salih
Khalil Salih
EAEmad Awada
Emad Awada
Mutasim NourMutasim Nour
Mutasim Nour
Connecting a single-phase or three-phase inverter to the grid in distributed generation applications requires synchronization with the grid. Synchronization of an inverter-connected distributed generation units in its basic form necessitates accurate information about the frequency and phase angle of the utility grid. Phase Locked Loop (PLL) circuit is usually used for the purpose of synchronization. However, deviation in the grid frequency from nominal value will cause errors in the PLL estimated outputs, and that’s a major drawback. Moreover, if the grid is heavily distorted with low order harmonics the estimation of the grid phase angle deteriorates resulting in higher oscillations (errors) appearing in the synchronization voltage signals. This paper proposes a modified time delay PLL (MTDPLL) technique that continuously updates a variable time delay unit to keep track of the variation in the grid frequency. The MTDPLL is implemented along a Multi-Harmonic Decoupling Cell (MHDC) to overcome the effects of distortion caused by gird lower order harmonics. The performance of the proposed MTDPLL is verified by simulation and compared in terms of performance and accuracy with recent PLL techniques.

29 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
Emad A. AwadaEmad A. Awada
Emad A. Awada
EREyad Radwan
Eyad Radwan
SASuzan Abed
Suzan Abed
AAAkram Al-Mahrouk
Akram Al-Mahrouk
Electrical vehicles are finding wide acceptance in the Jordanian transportation market; this has caused an accelerating shift in the emissions of greenhouse gases from the direct burning of fossil fuels consumed by the transportation sector towards the power generation sector. On the other hand, as electric vehicles gain more popularity, an extra load is added to the electrical power generation systems, raising essential concerns such as the capability of the power network to support this massive extra load and the increased emission of greenhouse gases caused by power plants. Studies show that Jordan’s weather is known for being bright, sunny, and very suitable for the generation of electric power from solar energy sources. Therefore, with an infrastructure that can support convenient off-grid charging, a huge burden will be taken off the national grid and the environment. Therefore, this work proposes a basic design for an off-grid PV-covered carport and presents a study of the economics and effectiveness of using such a system to charge electric vehicles owned by the students and employees of the Applied Science Private University. The study is based on actual solar irradiance data collected on-site during university working hours (8 a.m.–5 p.m.) to allow students and employees to charge their electric vehicles from an off-grid carport system while on campus. Space limitations for carport design, initial design cost, return on investment, and annual electricity consumption are discussed to demonstrate the benefits of such a system for both the consumer (convenience and low charging cost) and the power company provider (less load to maintain).

1 October 2022 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
Emad A. AwadaEmad A. Awada
Emad A. Awada
EREyad Radwan
Eyad Radwan
Mutasim NourMutasim Nour
Mutasim Nour
This paper presents a robust sliding mode controller of DC-DC buck converter for renewable energy applications, such as photovoltaic systems in off-grid configurations. Photovoltaic systems in off-grid configuration are exposed to significant variations in input voltage and power loads. The proposed sliding mode controller presents a simple and efficient method of continuously updating the duty cycle of a pulse width modulation unit (PWM) of a buck converter. The PWM unit is operated at constant switching frequency of 10 kHz carrier signal and varying duty cycle. The differences in input voltage and power load are treated as two bounded uncertainties, thus eliminating the need for input voltage sensor and output current sensors leaving the system with a single sensor required to measure the converter output voltage. That is, measured output voltage is compared with the reference voltage to continuously update the average duty cycle value of PWM unit. Adjustment of PWM duty cycle is performed while maintaining the sliding condition always fulfilled. The simulation results of the proposed controller showed robustness and accuracy against power load fluctuation, changes in desired output voltage, and variations in the input supply voltage that may result from the varying level of irradiance and temperature.

1 December 2005 in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
Verified
Journal Article
Closed access
PDF file
EREyad Radwan
Eyad Radwan
NMN. Mariun
N. Mariun
IAIshak Bin Aris
Ishak Bin Aris
SBS.M. Bash
S.M. Bash
AYA.H. Yatim
A.H. Yatim
Purpose – To provide a new and simple inverse rotor time constant identification method which can be used to update an indirect rotor field oriented controlled (IRFOC) induction motor algorithm. Design/methodology/approach – Two different equations are used to estimate the rotor flux in the stator reference frame. One of the equations is a function of the rotor time constant, rotor angular velocity and the stator currents. The other equation is a function of measured stator currents and voltages. The equation that uses the voltage and the current signals of the stator serves as reference model, however, the other equation works as an adjustable model with respect to the variation of the rotor time constant. Voltage signals used in the reference model equation are obtained from the measured DC bus voltage and the inverter gating signals. The proposed scheme is verified using a MATLAB/SIMULINK model for two different motors and experimentally using a DSP development tool (MCK 243) supplied by Technosoft S.A. Findings – The proposed estimator was able to successfully track the actual value of the inverse rotor time constant for different load torque and speed operating conditions. Increased oscillations in the estimated inverse rotor time constant appeared at lower speeds (below 10 per cent of rated speed) due to drift in a PI regulator (used at the estimator side), which was tuned under rated operating conditions and using parameters nominal values. Research limitations/implications – This estimation scheme is limited when near zero speed operation is demanded; otherwise it gives a simple and practical solution. A suggested way out of this, is to provide a self-tuning controller that can automatically adjust even for zero speed operation, or to automatically disconnect the estimator and take the most updated value as long as the operating speed is below a predetermined value. Originality/value – This paper presented a new inverse rotor time constant estimator for an IRFOC induction motor application and in conjunction rotor flux was estimated without voltage phase sensors.