17 July 2019 in Science Robotics
The use of implantable myoelectric sensors showed substantial improvements in prosthetic function of above-elbow amputees.
2 September 2016 in PLOS ONE
TPTatjana Paternostro-Sluga
Tatjana Paternostro-Sluga
+7
Hand-transplantation and improvements in the field of prostheses opened new frontiers in restoring hand function in below-elbow amputees. Both concepts aim at restoring reliable hand function, however, the indications, advantages and limitations for each treatment must be carefully considered depending on level and extent of amputation. Here we report our findings of a multi-center cohort study comparing hand function and quality-of-life of people with transplanted versus prosthetic hands. Hand function in amputees with either transplant or prostheses was tested with Action Research Arm Test (ARAT), Southampton Hand Assessment Procedure (SHAP) and the Disabilities of the Arm, Shoulder and Hand measure (DASH). Quality-of-life was compared with the Short-Form 36 (SF-36). Transplanted patients (n = 5) achieved a mean ARAT score of 40.86 ± 8.07 and an average SHAP score of 75.00 ± 11.06. Prosthetic patients (n = 7) achieved a mean ARAT score of 39.00 ± 3.61 and an average SHAP score of 75.43 ± 10.81. There was no significant difference between transplanted and prosthetic hands in ARAT, SHAP or DASH. While quality-of-life metrics were equivocal for four scales of the SF-36, transplanted patients reported significantly higher scores in “role-physical” (p = 0.006), “vitality” (p = 0.008), “role-emotional” (p = 0.035) and “mental-health” (p = 0.003). The indications for hand transplantation or prosthetic fitting in below-elbow amputees require careful consideration. As functional outcomes were not significantly different between groups, patient’s best interests and the route of least harm should guide treatment. Due to the immunosuppressive side-effects, the indication for allotransplantation must still be restrictive, the best being bilateral amputees.
19 July 2017 in Frontiers in Neuroscience
Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user’s intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.
12 February 2014 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Targeted muscle reinnervation (TMR) redirects nerves that have lost their target, due to amputation, to remaining muscles in the region of the stump with the intent of establishing intuitive myosignals to control a complex prosthetic device. In order to directly recover the neural code underlying an attempted limb movement, in this paper, we present the decomposition of high-density surface electromyographic (EMG) signals detected from three TMR patients into the individual motor unit spike trains. The aim was to prove, for the first time, the feasibility of decoding the neural drive that would reach muscles of the missing limb in TMR patients, to show the accuracy of the decoding, and to demonstrate the representativeness of the pool of extracted motor units. Six to seven flexible EMG electrode grids of 64 electrodes each were mounted over the reinnervated muscles of each patient, resulting in up to 448 EMG signals. The subjects were asked to attempt elbow extension and flexion, hand open and close, wrist extension and flexion, wrist pronation and supination, of their missing limb. The EMG signals were decomposed using the Convolution Kernel Compensation technique and the decomposition accuracy was evaluated with a signal-based index of accuracy, called pulse-to-noise ratio (PNR). The results showed that the spike trains of 3 to 27 motor units could be identified for each task, with a sensitivity of the decomposition >90%, as revealed by PNR. The motor unit discharge rates were within physiological values of normally innervated muscles. Moreover, the detected motor units showed a high degree of common drive so that the set of extracted units per task was representative of the behavior of the population of active units. The results open a path for a new generation of human-machine interfaces in which the control signals are extracted from noninvasive recordings and the obtained neural information is based directly on the spike trains of motor neurons.
27 January 2016 in Current Surgery Reports
Composite tissue transplantation and new developments in the field of prosthetics have opened new frontiers in the restoration of function among upper limb amputees. It is now possible to restore hand function in affected patients; however, the indications, advantages, and limitations for either hand transplantation or prosthetic fitting must be carefully considered depending on the level and extent of the limb loss. Hand transplantation allows comprehensive hand function to be restored, yet composite tissue transplantation comes with disadvantages, making this method a controversial topic in the hand surgical community. Alternatively, prosthetic limb replacement represents the standard of care for upper limb amputees, but results in the known limitations of function, sensation, and usage. The indication for hand transplantation or prosthetic fitting strongly depends on the level of amputation, as well as on the extent (unilateral/bilateral) of the amputation. In this review, we discuss the advantages and disadvantages of hand transplantation and prosthetic replacement for upper limb amputees in general, as well as in regard to the different levels of amputation.