Kwang Hyo Jung

Dr. Kwang Hyo Jung

Dept. of Naval Architecture and Ocean Engineering, Pusan National Uinveristy, Busan, Korea

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SHSang Soo Hwang
Sang Soo Hwang
SGSung Jin Gil
Sung Jin Gil
GLGang Nam Lee
Gang Nam Lee
JLJi Won Lee
Ji Won Lee
HPHyun Park
Hyun Park
SSSung Bu Suh
Sung Bu Suh
In this study, the environmental impacts of various alternative ship fuels for a coastal ferry were assessed by the life cycle assessment (LCA) analysis. The comparative study was performed with marine gas oil (MGO), natural gas, and hydrogen with various energy sources for a 12,000 gross tonne (GT) coastal ferry operating in the Republic of Korea (ROK). Considering the energy imports of ROK, i.e., MGO from Saudi Arabia and natural gas from Qatar, these countries were chosen to provide the MGO and the natural gas for the LCA. The hydrogen is considered to be produced by steam methane reforming (SMR) from natural gas with hard coal, nuclear energy, renewable energy, and electricity in the ROK model. The lifecycles of the fuels were analyzed in classifications of Well-to- Tank, Tank-to-Wake, and Well-to-Wake phases. The environmental impacts were provided in terms of global warming potential (GWP), acidification potential (AP), photochemical potential (POCP), eutrophication potential (EP), and particulate matter (PM). The results showed that MGO and natural gas cannot be used for ships to meet the International Maritime Organization’s (IMO) 2050 GHG regulation. Moreover, it was pointed out that the energy sources in SMR are important contributing factors to emission levels. The paper concludes with suggestions for a hydrogen application plan for ships from small, nearshore ships in order to truly achieve a ship with zero emissions based on the results of this study.

Verified
Journal Article
Open access
PDF file
SHSangsoo Hwang
Sangsoo Hwang
Byongug JeongByongug Jeong
Byongug Jeong
Kwang Hyo JungKwang Hyo Jung
Kwang Hyo Jung
MKMingyu Kim
Mingyu Kim
Peilin ZhouPeilin Zhou
Peilin Zhou
This research was focused on a comparative analysis of using LNG as a marine fuel with a conventional marine gas oil (MGO) from an environmental point of view. A case study was performed using a 50K bulk carrier engaged in domestic services in South Korea. Considering the energy exporting market for South Korea, the fuel supply chain was designed with the two largest suppliers: Middle East (LNG-Qatar/MGO-Saudi Arabia) and U.S. The life cycle of each fuel type was categorized into three stages: Well-to-Tank (WtT), Tank-to-Wake (TtW), and Well-to-Wake (WtW). With the process modelling, the environmental impact of each stage was analyzed based on the five environmental impact categorizes: Global Warming Potential (GWP), Acidification Potential (AP), Photochemical Potential (POCP), Eutrophication Potential (EP) and Particulate Matter (PM). Analysis results reveal that emission levels for the LNG cases are significantly lower than the MGO cases in all potential impact categories. Particularly, Case 1 (LNG import to Korea from Qatar) is identified as the best option as producing the lowest emission levels per 1.0 × 107 MJ of fuel consumption: 977 tonnages of CO2 equivalent (for GWP), 1.76 tonnages of SO2 equivalent (for AP), 1.18 tonnages of N equivalent (for EP), 4.28 tonnages of NMVOC equivalent (for POCP) and 26 kg of PM 2.5 equivalent (for PM). On the other hand, the results also point out that the selection of the fuel supply routes could be an important factor contributing to emission levels since longer distances for freight transportation result in more emissions. It is worth noting that the life cycle assessment can offer us better understanding of holistic emission levels contributed by marine fuels from the cradle to the grave, which are highly believed to remedy the shortcomings of current marine emission indicators.

Verified
Journal Article
Open access
PDF file
GLGang Nam Lee
Gang Nam Lee
JKJong Mu Kim
Jong Mu Kim
Kwang Hyo JungKwang Hyo Jung
Kwang Hyo Jung
HPHyun Park
Hyun Park
HJHag Soo Jang
Hag Soo Jang
JLJi Won Lee
Ji Won Lee
With increasing concerns about environmental pollution, the shipping industry has been considering various fuels as alternative power sources. This paper presents a study of the holistic environmental impacts of eco-friendly alternative ship fuels of marine gas oil (MGO), liquefied natural gas (LNG), and hydrogen across each of their life cycles, from their production to the operation of the ship. The environmental impacts of the fuels were estimated by life-cycle assessment (LCA) analysis in the categories of well-to-tank, tank-to-wake, and well-to-wake phases. The LCA analysis was targeted for a 170 gross tonnage (GT) nearshore ferry operating in the ROK, which was conceptually designed in the study to be equipped with the hydrogen fuel cell propulsion system. The environmental impact performance was presented with comparisons for the terms of global warming potential (GWP), acidification potential (AP), photochemical ozone creation potential (POCP), eutrophication potential (EP), and particulate matter (PM). The results showed that the hydrogen showed the highest GWP level during its life cycle due to the large amount of emissions in the hydrogen generation process through the steam methane reforming (SMR) method. The paper concludes with suggestions of an alternative fuel for the nearshore ferry and its production method based on the results of the study.

20 July 2020 in Processes
Verified
Journal Article
Open access
PDF file
QNQuang Khai Nguyen
Quang Khai Nguyen
Kwang Hyo JungKwang Hyo Jung
Kwang Hyo Jung
GLGang Nam Lee
Gang Nam Lee
SSSung Bu Suh
Sung Bu Suh
PTPeter To
Peter To
In this study, the pressure distribution and flow coefficient of a globe valve are investigated with a series of experiments conducted in a flow test loop. The experiments are performed on a three-inch model test valve from an eight-inch ANSI (American National Standards Institute) B16.11—Class 2500# prototype globe valve with various pump speeds and full range of valve openings. Both inherent and installed flow characteristics are measured, and the results show that the flow coefficient depends not only on the valve geometry and valve opening but also on the Reynolds number. When the Reynolds number exceeds a certain value, the flow coefficients are stable. In addition, the pressures at different positions in the upstream and the downstream of the valve are measured and compared with recommendation per ANSI/ISA-75.01 standard. The results show that, in single-phase flow, the discrepancies in pressure between different measurement locations within close range of 10 nominal diameter from the valve are inconsiderable.
1

11 July 2024 in Science of The Total Environment
Verified
Journal Article
Closed access
GLGang Nam Lee
Gang Nam Lee
JKJong Mu Kim
Jong Mu Kim
Kwang Hyo JungKwang Hyo Jung
Kwang Hyo Jung
HPHyun Park
Hyun Park

12 December 2016 in Concurrent Engineering
Verified
Journal Article
Closed access
JCJian Chai
Jian Chai
HCHung-Lin Chi
Hung-Lin Chi
XWXiangyu Wang
Xiangyu Wang
CWChangzhi Wu
Changzhi Wu
Kwang Hyo JungKwang Hyo Jung
Kwang Hyo Jung
Jae-Myung LeeJae-Myung Lee
Jae-Myung Lee
The application of automatic as-built modeling based on laser scanning can potentially facilitate progress tracking and control in industrial plant construction. Although notable work has been conducted in the as-built modeling field, the level of automation and ability for programs to recognize semantic information is low. Semantic information, such as an installation schedule for industrial components, is vital for identifying actual construction progress. Unfortunately, as the current practices lack the ability to use robust process mapping to turn such information into corresponding as-built models, the current successful rate of recognition remains low. To fill these gaps, this article describes a new as-built modeling process for industrial components by incorporating segmentation and three-dimensional object recognition techniques from computer vision fields. Following the generation of the as-built model, the tracking process is able to identify schedule delays through deviation analysis between the as-built and four-dimensional as-designed models. The modeling process can be integrated in a concurrent construction environment, which provides precise feedback for planners and site managers to simultaneously maintain the quality of construction plans. A case study is conducted, which demonstrates that the developed process enables as-built modeling with semantic information and automatic construction progress tracking. With a certain number of as-built components of a dehydration module being captured, a successful recognition rate of over 90% is achieved. Furthermore, the processing time of the case study lies within an acceptable time period, which supports efficient progress tracking. The results show the feasibility of the developed process, which promises to save time and labor costs during construction.