Bo Liu

Bo Liu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
XWXiaoxiong Wu
Xiaoxiong Wu
BLBo Liu
Bo Liu
BZBotao Zhang
Botao Zhang
XMXiaochen Mao
Xiaochen Mao
Numerical simulations have been performed to study the effect of the circumferential single-grooved casing treatment (CT) at multiple locations on the tip-flow stability and the corresponding control mechanism at three tip-clearance-size (TCS) schemes in a transonic axial flow compressor rotor. The results show that the CT is more efficient when its groove is located from 10% to 40% tip axial chord, and G2 (located at near 20% tip axial chord) is the best CT scheme in terms of stall-margin improvement for the three TCS schemes. For effective CTs, the tip-leakage-flow (TLF) intensity, entropy generation and tip-flow blockage are reduced, which makes the interface between TLF and mainstream move downstream. A quantitative analysis of the relative inlet flow angle indicates that the reduction of flow incidence angle is not necessary to improve the flow stability for this transonic rotor. The control mechanism may be different for different TCS schemes due to the distinction of the stall inception process. For a better application of CT, the blade tip profile should be further modified by using an optimization method to adjust the shock position and strength during the design of a more efficient CT.

21 January 2020 in Entropy
Verified
Journal Article
Open access
PDF file
BZBotao Zhang
Botao Zhang
BLBo Liu
Bo Liu
CHChangfu Han
Changfu Han
HZHang Zhao
Hang Zhao
To investigate the influence of the change of tip clearance size on the control effect of the endwall suction, the effects of endwall suction on the aerodynamic performance of the axial compressor cascade were studied numerically. Three tip clearance sizes of 0.5% h, 1.0% h, and 2.0% h (h is the blade height) were mainly considered. The results show that the endwall suction scheme whose coverage range was 8–33% axial chord can reduce the leakage flow and improve the aerodynamic performance by directly influencing the structure of tip leakage vortex. The overall total pressure loss coefficients of the three clearance size schemes at 0° angle of incidence with 0.4 inlet Mach number are reduced by about 10.3%, 10.8%, and 6.0%, respectively, at the suction flow rate of 0.7%. Under the same suction flow rate, the onset position of the tip leakage vortex of the cascade with small clearance is shifted from the 15% of the axial chord length of original to the 48% of the axial chord length, which with large clearance is nearly no changed. The leakage flow rate and the distance from the leakage vortex to the suction slot are the main reasons for the different control effect of the endwall suction under different tip clearance sizes. The difference of the spanwise distribution of flow field parameters may also cause the difference of flow control effect.

4 April 2024 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
XMXiaochen Mao
Xiaochen Mao
YJYingchen Jiao
Yingchen Jiao
HCHao Cheng
Hao Cheng
BZBotao Zhang
Botao Zhang
BLBo Liu
Bo Liu
Gap shape is an important factor affecting the tandem cascade performance. This paper uses the gap expansion angle (Kb−b) to define gap shape and studies the effect of Kb−b on the two-dimensional flow field and flow characteristic near the endwall in a highly-loaded subsonic tandem cascade. By changing the incidence angle from −20 to 10°, the Kb−b value increases, and the two-dimensional tandem cascade performance improves at positive incidence angles, while it descends at zero and negative incidence angles. Due to the influence of Kb−b on the camber of front and rear blades (RB), the optimal Kb−b should provide appropriate load distribution and sufficient gap flow strength. The corner stall more likely appears on the front blade near the endwall, which can suppress the flow separation on the rear blade to a certain extent. The Kb−b value near the endwall should be slightly larger than in the midspan to ensure a sufficient operating range for the front blade. For a highly loaded subsonic tandem cascade, the overall optimal range of Kb−b is between −12 and 0°.

18 August 2026 in Journal of the Global Power and Propulsion Society
Verified
Journal Article
Open access
PDF file
FCFei Chen
Fei Chen
XMXiaochen Mao
Xiaochen Mao
LFLei Fu
Lei Fu
LGLimin Gao
Limin Gao
BLBo Liu
Bo Liu
This study investigates the complete stall process of a counter-rotating axial compressor through multi-passage unsteady numerical simulations, integrating the Liutex vortex identification method and reduced-order variational mode decomposition (RVMD) technique. The analysis reveals that the tip secondary vortex (TSV) plays a pivotal role in stall inception. During stall initiation, two TSVs emerge within the tip passage: the upstream TSV generates backflow and undergoes periodic vortex shedding, while the downstream TSV interacts with adjacent blades, triggering leading-edge spillage that produces stall spikes. These TSVs collectively form an axially fluctuating structure with periodic and self-sustained unsteadiness, propagating circumferentially. The accumulation of fluctuation energy disrupts the stability of tip leakage vortex, ultimately causing complete blockage at the rotor 2 tip and initiating compressor stall. Furthermore, the RVMD technique proves effective in identifying non-periodic and transitional features during stall evolution, enabling efficient extraction of dominant flow structures from large-scale unsteady data. To address the high computational complexity of RVMD, singular value decomposition is employed for spatial dimensionality reduction. However, challenges persist in parameter optimization, often leading to over- or under-decomposition of flow characteristics. The findings highlight the dynamic interplay of TSV-driven mechanisms in stall development and demonstrate the potential of RVMD for complex flow diagnostics, while underscoring the need for improved adaptive parameter selection to enhance its practicality. This work provides insights into compressor stall dynamics and advances data-driven methods for turbomachinery flow analysis.