Microfluidic devices are gaining increasing popularity due to their wide applications in various research areas. Herein, we propose a two-layer multi-channel microfluidic device allowing for direct-contact cell-vessel co-culture. Using the device, we built a co-culture model of the outer blood-retina barrier (oBRB), mimicking the in vivo retinal pigment epithelial cells-Bruch membrane-fenestrated choroids. To demonstrate the versatility of the design, we further modified the device by inserting platinum electrodes for trans-epithelial electrical resistance (TEER) measurement, demonstrating the feasibility of on-chip assessment of the epithelial barrier integrity. Our proposed design allows for direct-contact co-culture of cell–cell or cell–vessel, modifiable for real-time evaluation of the state of the epithelial monolayers.
Genetically modified (GM) crops like corn and soy offer enhanced resistance traits but require consistent monitoring to manage gene flow, prevent resistant pests/weeds, and ensure regulatory compliance. In this study, we present a novel loop-mediated isothermal amplification (LAMP)-based microfluidic paper-based analytical device (μPAD) biosensor for the rapid and cost-effective detection of hybrid corn (Roundup Hybridization System 1, RHS1) and soy (Roundup-Ready 1 and 2, RR1 and RR2) traits directly from crude leaf extracts. Our μPAD-LAMP assay offers a promising solution for GM detection, characterized by its speed (within 60 min), simplicity (straightforward design), and affordability ($2.90 per test). We developed μPAD-LAMP cartridges and utilized an image analysis algorithm for time-resolved quantification of colorimetric changes, improving objectivity and accuracy. Our platform detected GM traits at 65 °C using a 1:7 dilution of leaf extracts in 0.12-0.25 % SDS in water, without needing DNA purification. The limit of detection (LoD) for RHS1, RR1, and RR2 targets was 1.40 × 103, 1.10 × 103, and 1.00 × 103 genomic copies per reaction, respectively, with our μPAD-LAMP system. This portable μPAD-LAMP platform achieves 100 % specificity, sensitivity, and accuracy in detecting GM corn and soy from leaf extracts, demonstrating its potential as a reliable on-site detection tool. Its adaptability to other GM crops or gene targets positions it as a promising standard for point-of-need (PON) assays in the GM industry.
Self-sustainable release of brain-derived neurotrophic factor (BDNF) to the retina using minimally invasive cell-encapsulation devices is a promising approach to treat retinal degenerative diseases (RDD). Herein, we describe such a self-sustainable drug delivery device with human retinal pigment epithelial (ARPE-19) cells (cultured on collagen coated polystyrene (PS) sheets) enclosed inside a 3D printed semi-porous capsule. The capsule was 3D printed with two photo curable polymers: triethylene glycol dimethacrylate (TEGDM) and polyethylene glycol dimethylacrylate (PEGDM). The capsule’s semi-porous membrane (PEGDM) could serve three functions: protecting the cells from body’s immune system by limiting diffusion (5.97 ± 0.11%) of large molecules like immunoglobin G (IgG)(150 kDa); helping the cells to survive inside the capsule by allowing diffusion (43.20 ± 2.16%) of small molecules (40 kDa) like oxygen and necessary nutrients; and helping in the treatment of RDD by allowing diffusion of cell-secreted BDNF to the outside environment. In vitro results showed a continuous BDNF secretion from the device for at least 16 days, demonstrating future potential of the cell-encapsulation device for the treatment of RDD in a minimally invasive and self-sustainable way through a periocular transplant.
This study provides design of a low-cost and open source add-on device that enhances the functionality of the popular EVOM® instrument for transepithelial/endothelial electrical resistance (TEER) measurement. The original EVOM® instrument is designed for measuring TEER in transwell samples manually using a pair of Ag/AgCl electrodes. The inconsistency in electrode placement, temperature variation, and a typically large (12–24 h) time interval between measurements result in large data variabilities. Thus, to solve the current limitation of the EVOM® instrument, we built an add-on device using a custom designed electronic board and a 3D printed electrode holder that allowed automated TEER measurements in multiple transwell samples. To demonstrate the functionality of the device prototype, we monitored TEER in 4 transwell samples containing retinal cells (ARPE-19) for 67 h. Furthermore, by monitoring temperature of the cell culture medium, we were able to detect fluctuations in TEER due to temperature change after the medium change process, and were able to correct the data offset. Although we demonstrated the use of our add-on device on EVOM® instrument only, the concept (multiplexing using digitally controlled relays) and hardware (custom data logger) presented here can be applied to more advanced TEER instruments to improve the performance of those devices.
Microfluidic paper-based analytical devices (µPADs) are an attractive format for colorimetric nucleic acid amplification tests (NAATs) because they enable low-cost, portable diagnostics in resource-limited settings. However, researchers often optimize colorimetric assays in liquid reactions in tubes before translating them to µPADs. Since both formats require separate instruments for incubation and real-time sensing, direct comparison of reactions between the two formats is difficult. To address these cross-platform limitations, we developed ThermiQuant™ AquaStream, a portable benchtop device (15 × 20 × 16 cm, ~ 5 kg; cost: USD 327) that supports seamless colorimetric loop-mediated isothermal amplification (LAMP) reactions in both µPADs and tubes under a common workflow. The system enables real-time reaction tracking (every 30 seconds) through onboard image processing, precise isothermal control (±0.5 °C) using a repurposed consumer-grade sous-vide heater, and medium-throughput (24 tubes or 42 µPADs). Testing with synthetic SARS-CoV-2 orf7ab DNA fragments demonstrated a limit of detection corresponding to a 95% probability of detection (LOD95) of 110 copies per reaction in tube (22 copies/µL) and 39 copies per reaction in µPADs (5 copies/µL), estimated using probit regression. In both formats the limit of quantification (LOQ), defined as the lowest concentration yielding a coefficient of variation (CV) of quantification time (Tq) ≤ 10%, was 250 copies/reaction resulting in a strong linear (R 2 = 0.98 & R 2 = 0.96 respectively for tube and µPADs) standard calibration curves. ThermiQuant™ AquaStream provides an affordable and versatile benchtop platform capable of supporting both tube- and µPAD-based colorimetric LAMP assays, serving as a proof-of-concept research tool for assay development and molecular diagnostics in One Health settings such as clinics, farms, and field environments.
ThermiQuant™ VitroMini combines dual-sided thin-film heating with a transparent imaging window to minimize through-thickness temperature gradients and enable real-time quantitative analysis of isothermal nucleic acid amplification reactions.