Virendra Kumar

Virendra Kumar

Auto-generated profile, based on publicly available information

Virendra Kumar

Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN 47906, USA

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2026 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
JWJiangshan Wang
Jiangshan Wang
SCSkyler Campbell
Skyler Campbell
VKVirendra Kumar
Virendra Kumar
MVMohit Verma
Mohit Verma
Microfluidic paper-based analytical devices (µPADs) are an attractive format for colorimetric nucleic acid amplification tests (NAATs) because they enable low-cost, portable diagnostics in resource-limited settings. However, researchers often optimize colorimetric assays in liquid reactions in tubes before translating them to µPADs. Since both formats require separate instruments for incubation and real-time sensing, direct comparison of reactions between the two formats is difficult. To address these cross-platform limitations, we developed ThermiQuant™ AquaStream, a portable benchtop device (15 × 20 × 16 cm, ~ 5 kg; cost: USD 327) that supports seamless colorimetric loop-mediated isothermal amplification (LAMP) reactions in both µPADs and tubes under a common workflow. The system enables real-time reaction tracking (every 30 seconds) through onboard image processing, precise isothermal control (±0.5 °C) using a repurposed consumer-grade sous-vide heater, and medium-throughput (24 tubes or 42 µPADs). Testing with synthetic SARS-CoV-2 orf7ab DNA fragments demonstrated a limit of detection corresponding to a 95% probability of detection (LOD95) of 110 copies per reaction in tube (22 copies/µL) and 39 copies per reaction in µPADs (5 copies/µL), estimated using probit regression. In both formats the limit of quantification (LOQ), defined as the lowest concentration yielding a coefficient of variation (CV) of quantification time (Tq) ≤ 10%, was 250 copies/reaction resulting in a strong linear (R 2 = 0.98 & R 2 = 0.96 respectively for tube and µPADs) standard calibration curves. ThermiQuant™ AquaStream provides an affordable and versatile benchtop platform capable of supporting both tube- and µPAD-based colorimetric LAMP assays, serving as a proof-of-concept research tool for assay development and molecular diagnostics in One Health settings such as clinics, farms, and field environments.

16 September 2026 in Lab on a Chip
Verified
Journal Article
Open access
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
DNDan Van Nguyen
Dan Van Nguyen
RMRachel A. Munds
Rachel A. Munds
ABAbdullah Bayram
Abdullah Bayram
MVMohit Verma
Mohit Verma
ThermiQuant™ VitroMini combines dual-sided thin-film heating with a transparent imaging window to minimize through-thickness temperature gradients and enable real-time quantitative analysis of isothermal nucleic acid amplification reactions.

9 January 2026 in bioRxiv
Verified
Preprint
Open access
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
VKVirendra Kumar
Virendra Kumar
AFAndrew Fleck
Andrew Fleck
Bilal AhmedBilal Ahmed
Bilal Ahmed
MVMohit Verma
Mohit Verma
Isothermal nucleic acid amplification tests (NAATs), such as loop-mediated isothermal amplification (LAMP) implemented on microfluidic paper-based analytical devices (µPADs), enable inexpensive and rapid (≤60 min) colorimetric molecular diagnostics; however, no existing instrument supports high-throughput (>100 reactions) quantitative analysis of colorimetric isothermal assays on paper substrates under controlled laboratory conditions. To address this gap, we developed ThermiQuant™ MegaScan, a scanner- and water-bath–based platform that accommodates a 160-reaction µPAD cartridge, maintains uniform incubation at 65 ± 0.5 °C, and enables real-time imaging every 30 s. We also developed accompanying software, Amplimetrics™, for automated µPAD detection and kinetic colorimetric analysis. Using paper-based colorimetric LAMP targeting the SARS-CoV-2 orf7ab region, the assay achieved a limit of detection at 95% probability (LOD95) of 34 copies per reaction (5 copies/µL) and a limit of quantification (LOQ) of 250 copies per reaction (33 copies/µL) using purified synthetic DNA targets, and achieved 72% sensitivity and 100% specificity relative to digital PCR (dPCR) for diluted human nasopharyngeal (NP) swab virus samples. We further evaluated the effects of viral and universal transport media (VTM/UTM) on assay performance and found that linear calibration derived from synthetic targets do not reliably translate to clinical samples in these media. Together, these results establish ThermiQuant™ MegaScan as a high-throughput laboratory research platform for standardized evaluation, optimization, and benchmarking of paper-based colorimetric nucleic acid amplification assays.

17 June 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
NRNafisa Rafiq
Nafisa Rafiq
JWJiangshan Wang
Jiangshan Wang
VKVirendra Kumar
Virendra Kumar
MVMohit Verma
Mohit Verma
African swine fever virus (ASFV) poses a major transboundary threat to global swine production, underscoring the need for rapid and field-deployable diagnostic tools. Although quantitative polymerase chain reaction (qPCR)-based assays are the standard molecular assay for ASFV detection, their reliance on centralized laboratory infrastructure, multi-step sample preparation, and trained personnel limit their utility for timely decision-making at the point of need (PON). Here, we report a portable molecular diagnostic platform that enables colorimetric quantitative loop-mediated isothermal amplification (qLAMP) directly from diluted whole blood on microfluidic paper-based analytical devices (μPADs). The assay targets the conserved ASFV viral protein 72 (VP72) and topoisomerase II (TOPII) genes and incorporates objective image-based colorimetric signal analysis to reduce user-dependent interpretation. Using plasmid DNA spiked into whole blood diluted to 5% (v/v) in 5% D-mannitol, the μPAD-LAMP assay achieved a limit of detection (LOD) of 25 copies per reaction (67 copies/μL of whole blood sample) for VP72 targets with no observed cross-reactivity against nine common swine pathogens, demonstrating 100% analytical sensitivity and specificity during in-house testing and 90% and 92% analytical sensitivity and specificity respectively in an external laboratory evaluation. The complete assay was performed within 60 minutes using a portable heating and imaging platform. Together, these results demonstrate a simple, DNA extraction-free molecular diagnostic approach that enables rapid and reliable ASFV detection from whole blood applicable to field-relevant conditions.

15 January 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
JWJiangshan Wang
Jiangshan Wang
SCSkyler Campbell
Skyler Campbell
VKVirendra Kumar
Virendra Kumar
MVMohit Verma
Mohit Verma
Microfluidic paper-based analytical devices (µPADs) are an attractive format for colorimetric nucleic acid amplification tests (NAATs) because they enable low-cost, portable diagnostics in resource-limited settings. However, researchers often optimize colorimetric assays in liquid reactions in tubes before translating them to µPADs. Since both formats require separate instruments for incubation and real-time sensing, direct comparison of reactions between the two formats is difficult. To address these cross-platform limitations, we developed ThermiQuant™ AquaStream, a portable benchtop device (15 × 20 × 16 cm, ∼5 kg; cost: USD 327) that supports seamless colorimetric loop-mediated isothermal amplification (LAMP) reactions in both µPADs and tubes under a common workflow. The system enables real-time reaction tracking (every 30 seconds) through onboard image processing, precise isothermal control (±0.5 °C) using a repurposed consumer-grade sous-vide heater, and medium-throughput (24 tubes or 42 µPADs). Testing with synthetic SARS-CoV-2 orf7ab DNA fragments demonstrated a limit of detection corresponding to a 95% probability of detection (LOD95) of 110 copies per reaction in tube (22 copies/µL) and 39 copies per reaction in µPADs (5 copies/µL), estimated using probit regression. In both formats the limit of quantification (LOQ), defined as the lowest concentration yielding a coefficient of variation (CV) of Tq ≤ 10%, was 250 copies/reaction resulting in a strong linear (R 2 = 0.98 & R 2 = 0.96 respectively for tube and µPADs) standard calibration curves. ThermiQuant™ AquaStream provides an affordable and versatile benchtop platform capable of supporting both tube- and µPAD-based colorimetric LAMP assays, serving as a proof-of-concept research tool for assay development and molecular diagnostics in One Health settings such as clinics, farms, and field environments.

9 March 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
DNDan Van Nguyen
Dan Van Nguyen
RMRachel A Munds
Rachel A Munds
ABAbdullah Bayram
Abdullah Bayram
MVMohit Verma
Mohit Verma
Maintaining precise isothermal conditions in portable nucleic acid amplification tests (NAATs) is critical for reproducible results but remains challenging with conventional single-sided thin-film heaters, which exhibit temperature gradients and strong dependence on ambient conditions. To close this gap, we engineered ThermiQuant™ VitroMini, a dual-sided heater design that achieves volumetric-level temperature uniformity using thin-film heaters while preserving optical transparency for real-time colorimetric loop-mediated isothermal amplification (LAMP) analysis on microfluidic paper-based analytical devices (µPADs). The device integrates two independently regulated indium tin oxide (ITO) heaters (8 Ω each) controlled by independent proportional–integral–derivative (PID) algorithms. Heaters were evaluated under controlled ambient environments of 4 °C (refrigerated), 23 °C (room temperature), and 50 °C (oven). Analytical tests were performed using a colorimetric LAMP assay targeting the SARS-CoV-2 orf7ab gene on µPADs preloaded with dried LAMP reagents, with time-lapse images (30 seconds interval) analyzed via Amplimetrics™ software. VitroMini maintained 65 ± 0.5 °C across 4 to 50 °C ambient conditions and achieved a limit of detection of 34 copies/reaction (4.5 copies/µL) and limit of quantification of 1000 copies/reaction (133 copies/µL), with quantification time (Tq) linearly correlated with log 10 DNA concentration. Dual-sided heating eliminated temperature bias, condensation artifacts, and ambient-dependent variability while preserving optical transparency for real-time quantitative LAMP reaction. ThermiQuant™ VitroMini bridges the gap between benchtop volumetric heaters and portable diagnostic devices, offering a compact, low-power platform for quantitative colorimetric molecular analysis on paper with potential for decentralized and field-deployable applications.