Dan Van Nguyen

Dan Van Nguyen

Auto-generated profile, based on publicly available information

Dan Van Nguyen

Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN 47906, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
HNHau Van Nguyen
Hau Van Nguyen
NHNguyen Quoc Huynh
Nguyen Quoc Huynh
VNVan Dan Nguyen
Van Dan Nguyen
Tae Seok SeoTae Seok Seo
Tae Seok Seo

16 September 2026 in Lab on a Chip
Verified
Journal Article
Open access
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
DNDan Van Nguyen
Dan Van Nguyen
RMRachel A. Munds
Rachel A. Munds
ABAbdullah Bayram
Abdullah Bayram
MVMohit Verma
Mohit Verma
ThermiQuant™ VitroMini combines dual-sided thin-film heating with a transparent imaging window to minimize through-thickness temperature gradients and enable real-time quantitative analysis of isothermal nucleic acid amplification reactions.

17 June 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
NRNafisa Rafiq
Nafisa Rafiq
JWJiangshan Wang
Jiangshan Wang
VKVirendra Kumar
Virendra Kumar
MVMohit Verma
Mohit Verma
African swine fever virus (ASFV) poses a major transboundary threat to global swine production, underscoring the need for rapid and field-deployable diagnostic tools. Although quantitative polymerase chain reaction (qPCR)-based assays are the standard molecular assay for ASFV detection, their reliance on centralized laboratory infrastructure, multi-step sample preparation, and trained personnel limit their utility for timely decision-making at the point of need (PON). Here, we report a portable molecular diagnostic platform that enables colorimetric quantitative loop-mediated isothermal amplification (qLAMP) directly from diluted whole blood on microfluidic paper-based analytical devices (μPADs). The assay targets the conserved ASFV viral protein 72 (VP72) and topoisomerase II (TOPII) genes and incorporates objective image-based colorimetric signal analysis to reduce user-dependent interpretation. Using plasmid DNA spiked into whole blood diluted to 5% (v/v) in 5% D-mannitol, the μPAD-LAMP assay achieved a limit of detection (LOD) of 25 copies per reaction (67 copies/μL of whole blood sample) for VP72 targets with no observed cross-reactivity against nine common swine pathogens, demonstrating 100% analytical sensitivity and specificity during in-house testing and 90% and 92% analytical sensitivity and specificity respectively in an external laboratory evaluation. The complete assay was performed within 60 minutes using a portable heating and imaging platform. Together, these results demonstrate a simple, DNA extraction-free molecular diagnostic approach that enables rapid and reliable ASFV detection from whole blood applicable to field-relevant conditions.

9 March 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
Bibek RautBibek Raut
Bibek Raut
GPGopal Palla
Gopal Palla
DNDan Van Nguyen
Dan Van Nguyen
RMRachel A Munds
Rachel A Munds
ABAbdullah Bayram
Abdullah Bayram
MVMohit Verma
Mohit Verma
Maintaining precise isothermal conditions in portable nucleic acid amplification tests (NAATs) is critical for reproducible results but remains challenging with conventional single-sided thin-film heaters, which exhibit temperature gradients and strong dependence on ambient conditions. To close this gap, we engineered ThermiQuant™ VitroMini, a dual-sided heater design that achieves volumetric-level temperature uniformity using thin-film heaters while preserving optical transparency for real-time colorimetric loop-mediated isothermal amplification (LAMP) analysis on microfluidic paper-based analytical devices (µPADs). The device integrates two independently regulated indium tin oxide (ITO) heaters (8 Ω each) controlled by independent proportional–integral–derivative (PID) algorithms. Heaters were evaluated under controlled ambient environments of 4 °C (refrigerated), 23 °C (room temperature), and 50 °C (oven). Analytical tests were performed using a colorimetric LAMP assay targeting the SARS-CoV-2 orf7ab gene on µPADs preloaded with dried LAMP reagents, with time-lapse images (30 seconds interval) analyzed via Amplimetrics™ software. VitroMini maintained 65 ± 0.5 °C across 4 to 50 °C ambient conditions and achieved a limit of detection of 34 copies/reaction (4.5 copies/µL) and limit of quantification of 1000 copies/reaction (133 copies/µL), with quantification time (Tq) linearly correlated with log 10 DNA concentration. Dual-sided heating eliminated temperature bias, condensation artifacts, and ambient-dependent variability while preserving optical transparency for real-time quantitative LAMP reaction. ThermiQuant™ VitroMini bridges the gap between benchtop volumetric heaters and portable diagnostic devices, offering a compact, low-power platform for quantitative colorimetric molecular analysis on paper with potential for decentralized and field-deployable applications.