ThermiQuant™ VitroMini combines dual-sided thin-film heating with a transparent imaging window to minimize through-thickness temperature gradients and enable real-time quantitative analysis of isothermal nucleic acid amplification reactions.
African swine fever virus (ASFV) poses a major transboundary threat to global swine production, underscoring the need for rapid and field-deployable diagnostic tools. Although quantitative polymerase chain reaction (qPCR)-based assays are the standard molecular assay for ASFV detection, their reliance on centralized laboratory infrastructure, multi-step sample preparation, and trained personnel limit their utility for timely decision-making at the point of need (PON). Here, we report a portable molecular diagnostic platform that enables colorimetric quantitative loop-mediated isothermal amplification (qLAMP) directly from diluted whole blood on microfluidic paper-based analytical devices (μPADs). The assay targets the conserved ASFV viral protein 72 (VP72) and topoisomerase II (TOPII) genes and incorporates objective image-based colorimetric signal analysis to reduce user-dependent interpretation. Using plasmid DNA spiked into whole blood diluted to 5% (v/v) in 5% D-mannitol, the μPAD-LAMP assay achieved a limit of detection (LOD) of 25 copies per reaction (67 copies/μL of whole blood sample) for VP72 targets with no observed cross-reactivity against nine common swine pathogens, demonstrating 100% analytical sensitivity and specificity during in-house testing and 90% and 92% analytical sensitivity and specificity respectively in an external laboratory evaluation. The complete assay was performed within 60 minutes using a portable heating and imaging platform. Together, these results demonstrate a simple, DNA extraction-free molecular diagnostic approach that enables rapid and reliable ASFV detection from whole blood applicable to field-relevant conditions.
Maintaining precise isothermal conditions in portable nucleic acid amplification tests (NAATs) is critical for reproducible results but remains challenging with conventional single-sided thin-film heaters, which exhibit temperature gradients and strong dependence on ambient conditions. To close this gap, we engineered ThermiQuant™ VitroMini, a dual-sided heater design that achieves volumetric-level temperature uniformity using thin-film heaters while preserving optical transparency for real-time colorimetric loop-mediated isothermal amplification (LAMP) analysis on microfluidic paper-based analytical devices (µPADs). The device integrates two independently regulated indium tin oxide (ITO) heaters (8 Ω each) controlled by independent proportional–integral–derivative (PID) algorithms. Heaters were evaluated under controlled ambient environments of 4 °C (refrigerated), 23 °C (room temperature), and 50 °C (oven). Analytical tests were performed using a colorimetric LAMP assay targeting the SARS-CoV-2 orf7ab gene on µPADs preloaded with dried LAMP reagents, with time-lapse images (30 seconds interval) analyzed via Amplimetrics™ software. VitroMini maintained 65 ± 0.5 °C across 4 to 50 °C ambient conditions and achieved a limit of detection of 34 copies/reaction (4.5 copies/µL) and limit of quantification of 1000 copies/reaction (133 copies/µL), with quantification time (Tq) linearly correlated with log 10 DNA concentration. Dual-sided heating eliminated temperature bias, condensation artifacts, and ambient-dependent variability while preserving optical transparency for real-time quantitative LAMP reaction. ThermiQuant™ VitroMini bridges the gap between benchtop volumetric heaters and portable diagnostic devices, offering a compact, low-power platform for quantitative colorimetric molecular analysis on paper with potential for decentralized and field-deployable applications.