JUAN ANTONIO PAZ

Dr. JUAN ANTONIO PAZ

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
JPJUAN ANTONIO PAZ
JUAN ANTONIO PAZ
CVCarlos Velasco-Santos
Carlos Velasco-Santos
Luis Jesús Villarreal-GómezLuis Jesús Villarreal-Gómez
Luis Jesús Villarreal-Gómez
EAEnrique Alcudia-Zacarias
Enrique Alcudia-Zacarias
AOAmelia Olivas-Sarabia
Amelia Olivas-Sarabia
GGGochi-Ponce Gochi-Ponce
Gochi-Ponce Gochi-Ponce

22 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
AÁAlan Saúl Álvarez-Suárez
Alan Saúl Álvarez-Suárez
SDSyed Gulam Dastager
Syed Gulam Dastager
NBNina Bogdanchikova
Nina Bogdanchikova
Daniel GrandeDaniel Grande
Daniel Grande
Alexey PestryakovAlexey Pestryakov
Alexey Pestryakov
Luis Jesús Villarreal-GómezLuis Jesús Villarreal-Gómez
Luis Jesús Villarreal-Gómez
Skin burns and ulcers are considered hard-to-heal wounds due to their high infection risk. For this reason, designing new options for wound dressings is a growing need. The objective of this work is to investigate the properties of poly (ε-caprolactone)/poly (vinyl-pyrrolidone) (PCL/PVP) microfibers produced via electrospinning along with sorbents loaded with Argovit™ silver nanoparticles (Ag-Si/Al2O3) as constituent components for composite wound dressings. The physicochemical properties of the fibers and sorbents were characterized using scanning electron microscopy (SEM), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR) and inductively coupled plasma optical emission spectroscopy (ICP-OES). The mechanical properties of the fibers were also evaluated. The results of this work showed that the tested fibrous scaffolds have melting temperatures suitable for wound dressings design (58–60 °C). In addition, they demonstrated to be stable even after seven days in physiological solution, showing no macroscopic damage due to PVP release at the microscopic scale. Pelletized sorbents with the higher particle size demonstrated to have the best water uptake capabilities. Both, fibers and sorbents showed antimicrobial activity against Gram-negative bacteria Pseudomona aeruginosa and Escherichia coli, Gram-positive Staphylococcus aureus and the fungus Candida albicans. The best physicochemical properties were obtained with a scaffold produced with a PCL/PVP ratio of 85:15, this polymeric scaffold demonstrated the most antimicrobial activity without affecting the cell viability of human fibroblast. Pelletized Ag/Si-Al2O3-3 sorbent possessed the best water uptake capability and the higher antimicrobial activity, over time between all the sorbents tested. The combination of PCL/PVP 85:15 microfibers with the chosen Ag/Si-Al2O3-3 sorbent will be used in the following work for creation of wound dressings possessing exudate retention, biocompatibility and antimicrobial activity.

27 February 2023 in Polymer-Plastics Technology and Materials
Verified
Journal Article
Closed access
AVAnayanci Mendoza Villicana
Anayanci Mendoza Villicana
GGGochi-Ponce Gochi-Ponce
Gochi-Ponce Gochi-Ponce
Daniel GrandeDaniel Grande
Daniel Grande
Jose Cornejo-BravoJose Cornejo-Bravo
Jose Cornejo-Bravo
AZArturo Zizumbo
Arturo Zizumbo
Luis Jesús Villarreal-GómezLuis Jesús Villarreal-Gómez
Luis Jesús Villarreal-Gómez
Currently, wound dressing technology is of significant interest in order to avoid undesired effects when burns or skin wounds are treated, especially their risk for microbial contamination and subsequent infection. Silver nanoparticles (AgNPs) have claimed importance as antimicrobial agents. For these reasons, a comparative study of different methods to synthesize electrospun polymeric fibers loaded with AgNPs (Ag+/PCLPVP) such as direct blending, ultraviolet irradiation, thermal treatment, and silver mirror reaction methods were done. The morphology and size of the fibers were investigated using the SEM, where the loading of the AgNPs in the fibers was measured with EDS analysis. FTIR, Raman spectroscopy, XRD, and TGA analysis were applied to measure the physicochemical properties of the fibers. DLS study allowed us to measure the size and surface charge of the obtained materials. The antimicrobial efficiency was carried out against Staphylococcus aureus and Escherichia coli bacteria for 24 h. Cytotoxicity was evaluated with the MTT assay using HFF1 cells. The results showed that the method with the best antimicrobial effect in both bacteria is the UV irradiation conducted before the electrospinning process. The UV radiation method also promotes good distribution efficiency, the physicochemical properties obtained were desirable for wound dressings, and the particle size within nanoparticle interval (~17 nm). Therefore, the most promising method for the preparation of Ag+/PCLPVPbased wound dressings was UV irradiation.

Verified
Journal Article
Open access
PDF file
JPJUAN ANTONIO PAZ
JUAN ANTONIO PAZ
GGGochi-Ponce Gochi-Ponce
Gochi-Ponce Gochi-Ponce
CVCarlos Velasco-Santos
Carlos Velasco-Santos
EAEnrique Alcudia-Zacarias
Enrique Alcudia-Zacarias
AZArturo Zizumbo
Arturo Zizumbo
Luis Jesús Villarreal-GómezLuis Jesús Villarreal-Gómez
Luis Jesús Villarreal-Gómez
The limited mechanical properties of composite materials, including stiffness, strength, and biocompatibility, restrict their effectiveness in biomedical applications. This research enhanced the mechanical properties and biocompatibility of polylactic acid and carbon fiber-reinforced composites (PLA/CFRCs) by incorporating multi-walled carbon nanotube (MWCNT) fillers. The methodology involved synthesizing MWCNTs and integrating them into PLA/CFRC laminates using fusion-blending, dispersion, and interlaminar spray-coating. Raman spectroscopy confirmed the presence of MWCNTs, with characteristic D and G band peaks and an ID/IG of 1.44 ± 0.089. SEM revealed MWCNTs in the PLA/CFRC matrix and allowed size determination, with an outer diameter range of 125–150 nm and a length of 14,407 ± 2869 nm. FTIR identified interactions between the matrix and the MWCNTs, evidenced by band shifts. TGA/DSC analysis showed thermal stability above 338 °C for all composites. The tensile tests revealed that all composites had values greater than 19 GPa for the elastic modulus and 232 MPa for the ultimate strength. Cytotoxicity assays confirmed biocompatibility, and all samples maintained a cell growth rate greater than 80%. This study highlighted the potential of nanotechnology to optimize the mechanical behavior of polymer-based composites, expanding their applicability in biomedical fields.

26 September 2018 in REVISTA DE CIENCIAS TECNOLÓGICAS
Verified
Journal Article
Open access
PDF file
MRManuel-Javier Rosel-Solis
Manuel-Javier Rosel-Solis
JSJavier Molina Salazar
Javier Molina Salazar
JPJUAN ANTONIO PAZ
JUAN ANTONIO PAZ
JOJuan Antonio Ruiz Ochoa
Juan Antonio Ruiz Ochoa
En el presente trabajo se revisa el estado del arte que guarda la manufactura aditiva en cuanto a sus avances en la mejora de sus materiales, específicamente, a través de la incorporación de materiales compuestos, como la fibra de carbono. Además, se hace una revisión de los procesos convencionales de manufactura de materiales compuestos y se analiza el grado de aplicación de la manufactura aditiva y los materiales compuestos en la manufactura de prótesis transtibiales prostéticas y de uso deportivo, con el objetivo de identificar oportunidades de mejora.

31 December 2023 in REVISTA DE CIENCIAS TECNOLÓGICAS
Verified
Journal Article
Open access
PDF file
MJMaría Fernanda De Jesús-Ramírez
María Fernanda De Jesús-Ramírez
APArturo Abundez Pliego
Arturo Abundez Pliego
EAEnrique Alcudia-Zacarias
Enrique Alcudia-Zacarias
JPJUAN ANTONIO PAZ
JUAN ANTONIO PAZ
SBSalomón Blanco-Figueroa
Salomón Blanco-Figueroa
En esta investigación se presenta el análisis y comparación de los resultados reportados en la literatura de 1987 al 2023 relacionados con la capacidad de absorción de energía específica de columnas tubulares de materiales compuestos, los cuales se clasificaron en tres categorías: a) laminados con fibras en orientación de [0,90], b) laminados con fibras unidireccionales, y 3) laminados con laminados multidireccionales. Se examinó la absorción de energía específica (SEA) y se realizaron comparaciones entre los estudios. Los resultados exhibieron una amplia dispersión en los datos, incluso para configuraciones aparentemente similares. Las diferencias se atribuyen a factores como dimensiones de probetas, materiales utilizados y técnicas de ensayo. Además, se observó la falta de normativas estandarizadas, lo que dificulta la comparación y la identificación de patrones consistentes. Se concluye que la implementación de estándares unificados mejoraría la coherencia y comparabilidad de los resultados, proporcionando una comprensión más profunda de estos materiales en aplicaciones futuras.