Lourdes Farrugia

Dr. Lourdes Farrugia

University of Malta, Valletta, Malta
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCJeantide Said Camilleri
Jeantide Said Camilleri
LFLourdes Farrugia
Lourdes Farrugia
Sergio CurtoSergio Curto
Sergio Curto
DRDario Rodrigues
Dario Rodrigues
Laura FarinaLaura Farina
Laura Farina
CHARLES SAMMUTCHARLES SAMMUT
CHARLES SAMMUT
Electromagnetic thermal therapies for cancer treatment, such as microwave hyperthermia, aim to heat up a targeted tumour site to temperatures within 40 and 44 °C. Computational simulations used to investigate such heating systems employ the Pennes’ bioheat equation to model the heat exchange within the tissue, which accounts for several tissue properties: density, specific heat capacity, thermal conductivity, metabolic heat generation rate, and blood perfusion rate. We present a review of these thermal and physiological properties relevant for hyperthermia treatments of breast including fibroglandular breast, fatty breast, and breast tumours. The data included in this review were obtained from both experimental measurement studies and estimated properties of human breast tissues. The latter were used in computational studies of breast thermal treatments. The measurement methods, where available, are discussed together with the estimations and approximations considered for values where measurements were unavailable. The review concludes that measurement data for the thermal and physiological properties of breast and tumour tissue are limited. Fibroglandular and fatty breast tissue properties are often approximated from those of generic muscle or fat tissue. Tumour tissue properties are mostly obtained from approximating equations or assumed to be the same as those of glandular tissue. We also present a set of reliable data, which can be used for more accurate modelling and simulation studies to better treat breast cancer using thermal therapies.

29 June 2016 in Electromagnetic Biology and Medicine
Verified
Journal Article
Closed access
PDF file
LFLourdes Farrugia
Lourdes Farrugia
PWP. Schembri Wismayer
P. Schembri Wismayer
LML. Zammit Mangion
L. Zammit Mangion
CHARLES SAMMUTCHARLES SAMMUT
CHARLES SAMMUT
In this article, we report on the characterization of the dielectric properties of in vivo rat liver at 36.4°C from 500 MHz up to 40 GHz with less than 5% uncertainty. The measured data were fitted to a Cole–Cole model and dielectric parameters are presented together with their respective 95% confidence interval. The root mean square error is 0.42. Moreover, ex vivo measurements were conducted in situ at 1, 2, 4 and 6 min after animal death and are compared to in vivo measurements. The results show that immediate changes in and are within experimental uncertainty, and therefore changes between in vivo and published ex vivo dielectric properties can be attributed to tissue hydration.

11 January 2024 in IEEE Access
Verified
Journal Article
Open access
LFLourdes Farrugia
Lourdes Farrugia
Emily PorterEmily Porter
Emily Porter
RCRaquel C. Conceição
Raquel C. Conceição
Simona Di MeoSimona Di Meo
Simona Di Meo
DGDaniela M. Godinho
Daniela M. Godinho
APAzadeh Peyman
Azadeh Peyman
Despite the significant number of studies published on the measurements of complex permittivity of biological tissues in the last thirty years, implementing a successful measurement program for dielectric measurements can still present a challenge for researchers. Most problems are not theoretical but of methodological or practical nature. In this article, lessons learned from experiences with goal-oriented measurements are presented by structuring them into practical guidelines for efficient and useful measurements of dielectric properties of biological tissues, aimed at addressing gaps in knowledge. Issues related to calibration, validation of the measurement system and data collection procedures are addressed from a practical perspective. This will help support reproducibility of measurements. In addition, guidelines for data analysis and data reporting are provided. The latter is also supported by a data analysis tool developed in MATLAB, made available as open source. This facilitates the harmonisation and merging of different datasets, ease of interpreting and re-using of data and comparison of data across studies. Additionally, a data repository is presented for uploading of dielectric data of biological tissues, along with the corresponding meta-data describing the experiments. These guidelines are the result of the work carried out by a dedicated working group in the project COST Action MyWAVE.

18 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Julian BonelloJulian Bonello
Julian Bonello
Andrea DeMarcoAndrea DeMarco
Andrea DeMarco
IFIman Farhat
Iman Farhat
LFLourdes Farrugia
Lourdes Farrugia
CHARLES SAMMUTCHARLES SAMMUT
CHARLES SAMMUT
Medical devices making use of radio frequency (RF) and microwave (MW) fields have been studied as alternatives to existing diagnostic and therapeutic modalities since they offer several advantages. However, the lack of accurate knowledge of the complex permittivity of different biological tissues continues to hinder progress in of these technologies. The most convenient and popular measurement method used to determine the complex permittivity of biological tissues is the open-ended coaxial line, in combination with a vector network analyser (VNA) to measure the reflection coefficient (S11) which is then converted to the corresponding tissue permittivity using either full-wave analysis or through the use of equivalent circuit models. This paper proposes an innovative method of using artificial neural networks (ANN) to convert measured S11 to tissue permittivity, circumventing the requirement of extending the VNA measurement plane to the coaxial line open end. The conventional three-step calibration technique used with coaxial open-ended probes lacks repeatability, unless applied with extreme care by experienced persons, and is not adaptable to alternative sensor antenna configurations necessitated by many potential diagnostic and monitoring applications. The method being proposed does not require calibration at the tip of the probe, thus simplifying the measurement procedure while allowing arbitrary sensor design, and was experimentally validated using S11 measurements and the corresponding complex permittivity of 60 standard liquid and 42 porcine tissue samples. Following ANN training, validation and testing, we obtained a prediction accuracy of 5% for the complex permittivity.

1 January 2024 in ASME Open Journal of Engineering
Verified
Journal Article
Closed access
PDF file
Emily PorterEmily Porter
Emily Porter
LFLourdes Farrugia
Lourdes Farrugia
PPPunit Prakash
Punit Prakash
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
DSDevashish Shrivastava
Devashish Shrivastava
Sergio CurtoSergio Curto
Sergio Curto
The dielectric properties of biological tissues are key parameters that support the design and usability of a wide range of electromagnetic-based medical applications, including for diagnostics and therapeutics, and allow the determination of safety and health effects due to exposure to electromagnetic fields. While an extensive body of literature exists that reports on values of these properties for different tissue types under different measurement conditions, it is now evident that there are large uncertainties and inconsistencies between measurement reports. Due to varying measurement techniques, limited measurement validation strategies, and lack of metadata reporting and confounder control, reported dielectric properties suffer from a lack of repeatability and questionable accuracy. Recently, the American Society of Mechanical Engineers (ASME) Thermal Medicine Standards Committee was formed, which included a Tissue Properties working group. This effort aims to support the translation and commercialization of medical technologies, through the development of a standard lexicon and standard measurement protocols. In this work, we present initial results from the Electromagnetic Tissue Properties subgroup. Specifically, this paper reports a critical gap analysis facing the standardization pathway for the dielectric measurement of biological tissues. All established measurement techniques are examined and compared, and emerging ones are assessed. Perspectives on the importance and challenges in measurement validation, accuracy calculation, metadata collection, and reporting are also discussed.

14 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea CataldoAndrea Cataldo
Andrea Cataldo
IFIman Farhat
Iman Farhat
LFLourdes Farrugia
Lourdes Farrugia
Raffaele PersicoRaffaele Persico
Raffaele Persico
RSRaissa Schiavoni
Raissa Schiavoni
Soil monitoring is a key topic from several perspectives, such as moisture level control for irrigation management and anti-contamination purposes. Monitoring the latter is becoming even more important due to increasing environmental pollution. As a direct consequence, there is a strong demand for innovative monitoring systems that are low cost, provide for quasi-real time and in situ monitoring, high sensitivity, and adequate accuracy. Starting from these considerations, this paper addresses the implementation of a microwave reflectometry based-system utilizing a customized bifilar probe and a miniaturized Vector Network Analyzer (m-VNA). The main objective is to relate frequency-domain (FD) measurements to the features of interest, such as the water content and/or the percentage of some polluting substances, through an innovative automatable procedure to retrieve the Debye dielectric parameters of the soil under different conditions. The results from this study confirm the potential of microwave reflectometry for moisture monitoring and contamination detection.