Abasin Ulasyar

Dr. Abasin Ulasyar


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
MNMuhammad Nadeem
Muhammad Nadeem
KIKashif Imran
Kashif Imran
AKABRAIZ KHATTAK
ABRAIZ KHATTAK
AUAbasin Ulasyar
Abasin Ulasyar
APAnamitra Pal
Anamitra Pal
MPMalhar Padhee
Malhar Padhee
Flexible AC Transmission Systems (FACTS) play an important role in minimizing power losses and voltage deviations while increasing the real power transfer capacity of transmission lines. The extent to which these devices can provide benefits to the transmission network depend on their optimal location and sizing. However, finding appropriate locations and sizes of these devices in an electrical network is difficult since it is a nonlinear problem. This paper proposes a technique for the optimal placement and sizing of FACTS, namely the Thyristor-Controlled Series Compensators (TCSCs), Shunt VARs Compensators (SVCs), and Unified Power Flows Controllers (UPFCs). To find the optimal locations of these devices in a network, weak buses and lines are determined by constructing PV curves of load buses, and through the line stability index. Then, the whale optimization algorithm (WOA) is employed not only to find an ideal ratings for these devices but also the optimal coordination of SVC, TCSC, and UPFC with the reactive power sources already present in the network (tap settings of transformers and reactive power from generators). The objective here is the minimization of the operating cost of the system that consists of active power losses and FACTS devices cost. The proposed method is applied to the IEEE 14 and 30 bus systems. The presented technique is also compared with Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The findings showed that total system operating costs and transmission line losses were considerably reduced by WOA as compared to existing metaheuristic optimization techniques.

19 July 2021 in IEEE Access
Verified
Journal Article
Open access
WAWaleed Ali
Waleed Ali
AUAbasin Ulasyar
Abasin Ulasyar
MMMussawir Ul Mehmood
Mussawir Ul Mehmood
AKAbraiz Khattak
Abraiz Khattak
KIKashif Imran
Kashif Imran
SNShibli Nisar
Shibli Nisar
Due to the increase in penetration of renewable energy sources, the control technique plays a vital role to determine the performance of Microgrid (MG). Recently, the Internet of Things (IoT) and cloud computing has gained significance in solving various industrial problems. Robust and scalable Information Communication Technology (ICT) infrastructure is critical for efficient control of MG. IoT Devices with efficient measurement and control capability can play a key role in the MG environment. In this paper three layers hierarchical control of inverter based MG was developed using cloud-based IoT infrastructure and machine learning (ML) based islanding detection scheme. MG was operated in both island and grid connected mode. In the Primary layer, a voltage frequency (V-F) droop control with virtual impedance control was applied to avoid the disturbances in island mode. Moreover, Active Reactive (P-Q) power control was used for grid connected mode. In the secondary layer voltage and frequency deviations were removed by using the decentralized averaging based method. Voltage and frequency from each distributed generator (DG) were communicated by using a lightweight IoT-based protocol through an edge device (ED). Context-aware policy (CAP) was adopted in ED to optimize traffic flow over a communication network (CN) by comparing the difference in the present and previous data values. In the tertiary layer, a cloud-based ML model was developed using an artificial neural network (ANN) for islanding detection. ANN model was trained by data produced by simulating islanding scenarios in Matlab. Phasor measurement unit (PMU) data was communicated to the cloud for island prediction. The Proposed scheme was implemented on a modified IEEE-13 bus system with four inverter-based distributed generators (DGs) in Matlab, and Microsoft cloud services were used. The successful implementation of MG hierarchical control using an IoT feedback network with less data traffic along with cloud-based islanding detection using machine learning are the main contributions in this work. The whole system achieves stability within 2 seconds of islanding according to IEEE 1547 standards.

14 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MKMuhammad Haris Khan
Muhammad Haris Khan
AUAbasin Ulasyar
Abasin Ulasyar
AKABRAIZ KHATTAK
ABRAIZ KHATTAK
HZHaris Sheh Zad
Haris Sheh Zad
MAMohammad Alsharef
Mohammad Alsharef
NUNasim Ullah
Nasim Ullah
There is increasing growth in load demands and financial strain to upgrade the present power distribution system. It faces challenges such as power losses, voltage deviations, lack of reliability and voltage instability. There is also a sense of responsibility in the wake of environmental and energy crises to adopt distributed renewable resources for power generation. These challenges can be resolved by optimally allocating distributed generators (DGs) at different suitable locations in the radial power distribution system. Optimal allocation is a non-linear problem which is solved by powerful metaheuristic optimization algorithms. In this work, an objective function is introduced to optimally size four different types of DGs by utilizing honey badger algorithm (HBA), and comparison is drawn with grey wolf optimization (GWO) and whale optimization algorithm (WOA). The objective is to boost the voltage profile and minimize the power losses of the standard IEEE 33bus and 69-bus radial power distribution system. It is observed from the simulation results that honey badger algorithm is faster than grey wolf optimization and whale optimization algorithm in reaching accurate and optimum results in a mere one and two iterations for IEEE 33-bus and 69-bus systems, respectively. Additionally, power losses are reduced to 71% and 70% for IEEE 33-bus and 69-bus, respectively.

26 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
MMMussawir Mehmood
Mussawir Mehmood
AUAbasin Ulasyar
Abasin Ulasyar
AKABRAIZ KHATTAK
ABRAIZ KHATTAK
KIKashif Imran
Kashif Imran
HZHaris Sheh Zad
Haris Sheh Zad
SNShibli Nisar
Shibli Nisar
Power restoring time in power distribution systems (PDS) can be minimized by using efficient fault localization techniques. This paper proposes a novel, robust and scalable cloud based internet of things (IoT) solution for identification and localization of faults in PDS. For this purpose, a new algorithm is developed that can detect single and multiple simultaneous faults in the presence of single and multiple device or sensor failures. The algorithm has utilized a zone based approach that divides a PDS into different zones. A current sensing device (CSD) was deployed at the boundary of a zone. The function of CSD is to provide time synchronized current measurements and communicate with a cloud server through an edge device (ED). Another contribution of this research work is the unique implementation of context aware policy (CAP) in ED. Due to CAP, only those measurements are transmitted to cloud server that differ from the previously transmitted measurements. The cloud server performed calculations at regular intervals to detect faults in PDS. A relational database model was utilized to log various fault events that occur in PDS. An IEEE 37 node test feeder was selected as PDS to observe the performance of our solution. Two test cases were designed to simulate individual and multiple simultaneous faults in PDS. A third test case was implemented to demonstrate the robustness and scalability of proposed solution to detect multiple simultaneous faults in PDS when single and multiple sensor failures were encountered. It was observed that the new algorithm successfully localized the faults for all the three cases. Consequently, significant reductions were noticed in the amount of data that was sent to the cloud server. In the end, a comparison study of a proposed solution was performed with existing methods to further highlight the benefits of our technique.

2 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
ZHZeeshan Haider
Zeeshan Haider
AUAbasin Ulasyar
Abasin Ulasyar
AKABRAIZ KHATTAK
ABRAIZ KHATTAK
HZHaris Sheh Zad
Haris Sheh Zad
AMAlsharef Mohammad
Alsharef Mohammad
NUNasim Ullah
Nasim Ullah
High conversion gain is often required for the grid integration of renewable energy resources such as PV, fuel cells, and wind. It is desired that the stress across switches is lower when higher voltage gain is attained. Similarly, it is also preferred that the converter can achieve high voltage gain without operating at higher duty cycle values. This article presents a novel high-gain CUK converter (HGCC) that uses voltage-multiplier units. The HGCC is a combination of a modified CUK converter and voltage-multiplier units (VMUs). The converter utilizes a boost converter as an input to the modified CUK converter, resulting in an increase in the gain value. The voltage gain of HGCC is increased further by placing VMUs. Based on its overall design, the HGCC inherits various advantages of the CUK converter, such as continuous input and output current, resulting in low input and output current ripples. A mathematical model is developed for the HGCC, which helps calculate its voltage gain at different stages. The model is developed considering ideal elements without conduction and switching losses. Generalized equations for output voltage and gain are derived for n level converter. A simulation study was performed in MATLAB/Simulink that further highlights the advantages of the HGCC. Voltage stresses across different components and the switching of MOSFET and diodes are studied in simulations. An experimental setup is established for hardware prototyping of the converter and validation with the simulation and Mathematical models.

16 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
MMMussawir Mehmood
Mussawir Mehmood
AUAbasin Ulasyar
Abasin Ulasyar
WAWaleed Ali
Waleed Ali
Kamran ZebKamran Zeb
Kamran Zeb
HZHaris Sheh Zad
Haris Sheh Zad
Hee-Je KimHee-Je Kim
Hee-Je Kim
Solar energy is considered the most abundant form of energy available on earth. However, the efficiency of photovoltaic (PV) panels is greatly reduced due to the accumulation of dust particles on the surface of PV panels. The optimization of the cleaning cycles of a PV power plant through condition monitoring of PV panels is crucial for its optimal performance. Specialized equipment and weather stations are deployed for large-scale PV plants to monitor the amount of soil accumulated on panel surface. However, not much focus is given to small- and medium-scale PV plants, where the costs associated with specialized weather stations cannot be justified. To overcome this hurdle, a cost-effective and scalable solution is required. Therefore, a new centralized cloud-based solar conversion recovery system (SCRS) is proposed in this research work. The proposed system utilizes the Internet of Things (IoT) and cloud-based centralized architecture, which allows users to remotely monitor the amount of soiling on PV panels, regardless of the scale. To improve scalability and cost-effectiveness, the proposed system uses low-cost sensors and an artificial neural network (ANN) to reduce the amount of hardware required for a soiling station. Multiple ANN models with different numbers of neurons in hidden layers were tested and compared to determine the most suitable model. The selected ANN model was trained using the data collected from an experimental setup. After training the ANN model, the mean squared error (MSE) value of 0.0117 was achieved. Additionally, the adjusted R-squared (R2) value of 0.905 was attained on the test data. Furthermore, data is transmitted from soiling station to the cloud server wirelessly using a message queuing telemetry transport (MQTT) lightweight communication protocol over Wi-Fi network. Therefore, SCRS depicts a complete wireless sensor network eliminating the need for extra wiring. The average percentage error in the soiling ratio estimation was found to be 4.33%.