In this paper, a hybrid magnetic bearing (HMB) prototype system is designed and analyzed. Two compact bearings are used to suspend the rotor in five degrees of freedom. Electromagnets are used for axial suspension of the rotor, while permanent magnets are used for the passive radial stability. A brushless DC motor is designed in order to rotate the shaft around its axis. The 3-D finite-element model of the HMB system is established and distribution of magnetic fields in the air gaps and magnetic forces on the rotor under various control currents and displacements is calculated. A nonlinear adaptive sliding-mode controller is designed for the position control of the rotor in axial direction. Since the control characteristics of the active magnetic bearing system are highly nonlinear and time varying with external interference, a radial basis function compensator is designed first, and then, a sliding-mode control law is used to generate the control input. The stability analysis for the designed controller is given based on the Lyapunov theorem. Experimental setup is built to guide the design process. The performance of the HMB system based on the designed control algorithm is evaluated under different operating conditions.
Due to the increase in penetration of renewable energy sources, the control technique plays a vital role to determine the performance of Microgrid (MG). Recently, the Internet of Things (IoT) and cloud computing has gained significance in solving various industrial problems. Robust and scalable Information Communication Technology (ICT) infrastructure is critical for efficient control of MG. IoT Devices with efficient measurement and control capability can play a key role in the MG environment. In this paper three layers hierarchical control of inverter based MG was developed using cloud-based IoT infrastructure and machine learning (ML) based islanding detection scheme. MG was operated in both island and grid connected mode. In the Primary layer, a voltage frequency (V-F) droop control with virtual impedance control was applied to avoid the disturbances in island mode. Moreover, Active Reactive (P-Q) power control was used for grid connected mode. In the secondary layer voltage and frequency deviations were removed by using the decentralized averaging based method. Voltage and frequency from each distributed generator (DG) were communicated by using a lightweight IoT-based protocol through an edge device (ED). Context-aware policy (CAP) was adopted in ED to optimize traffic flow over a communication network (CN) by comparing the difference in the present and previous data values. In the tertiary layer, a cloud-based ML model was developed using an artificial neural network (ANN) for islanding detection. ANN model was trained by data produced by simulating islanding scenarios in Matlab. Phasor measurement unit (PMU) data was communicated to the cloud for island prediction. The Proposed scheme was implemented on a modified IEEE-13 bus system with four inverter-based distributed generators (DGs) in Matlab, and Microsoft cloud services were used. The successful implementation of MG hierarchical control using an IoT feedback network with less data traffic along with cloud-based islanding detection using machine learning are the main contributions in this work. The whole system achieves stability within 2 seconds of islanding according to IEEE 1547 standards.
There is increasing growth in load demands and financial strain to upgrade the present power distribution system. It faces challenges such as power losses, voltage deviations, lack of reliability and voltage instability. There is also a sense of responsibility in the wake of environmental and energy crises to adopt distributed renewable resources for power generation. These challenges can be resolved by optimally allocating distributed generators (DGs) at different suitable locations in the radial power distribution system. Optimal allocation is a non-linear problem which is solved by powerful metaheuristic optimization algorithms. In this work, an objective function is introduced to optimally size four different types of DGs by utilizing honey badger algorithm (HBA), and comparison is drawn with grey wolf optimization (GWO) and whale optimization algorithm (WOA). The objective is to boost the voltage profile and minimize the power losses of the standard IEEE 33bus and 69-bus radial power distribution system. It is observed from the simulation results that honey badger algorithm is faster than grey wolf optimization and whale optimization algorithm in reaching accurate and optimum results in a mere one and two iterations for IEEE 33-bus and 69-bus systems, respectively. Additionally, power losses are reduced to 71% and 70% for IEEE 33-bus and 69-bus, respectively.
12 October 2017 in IEEE Transactions on Industrial Electronics
In this paper, a novel design for the axial flow blood pump is proposed, based on the bearingless permanent magnet (PM) motor concept. The design of the impeller, the rotor, and the stator is explained. The axial length of the impeller is optimized based on the finite-element analysis (FEA), and because of reduced axial length of the rotor, only one radial active magnetic bearing is used, whose functionality is embedded in the same stator, which is used for generating motor torque. A novel design of the rotor and the stator is proposed for measuring the radial position of the rotor using four linear Hall effect sensors. This sensor assembly can measure the radial position of the rotor with good accuracy. The angular position of the rotor is measured with two Hall effect sensors. The 3-D FEA of the complete system is performed, and suspension forces, stiffness, and torques are evaluated under various control conditions. The control strategy for the bearingless PM motor based on the Hall effect position sensors is explained. The experimental setup is built in order to guide the process of design. The experimental results of the system are evaluated under different operating conditions and compared with FEA results.
Power restoring time in power distribution systems (PDS) can be minimized by using efficient fault localization techniques. This paper proposes a novel, robust and scalable cloud based internet of things (IoT) solution for identification and localization of faults in PDS. For this purpose, a new algorithm is developed that can detect single and multiple simultaneous faults in the presence of single and multiple device or sensor failures. The algorithm has utilized a zone based approach that divides a PDS into different zones. A current sensing device (CSD) was deployed at the boundary of a zone. The function of CSD is to provide time synchronized current measurements and communicate with a cloud server through an edge device (ED). Another contribution of this research work is the unique implementation of context aware policy (CAP) in ED. Due to CAP, only those measurements are transmitted to cloud server that differ from the previously transmitted measurements. The cloud server performed calculations at regular intervals to detect faults in PDS. A relational database model was utilized to log various fault events that occur in PDS. An IEEE 37 node test feeder was selected as PDS to observe the performance of our solution. Two test cases were designed to simulate individual and multiple simultaneous faults in PDS. A third test case was implemented to demonstrate the robustness and scalability of proposed solution to detect multiple simultaneous faults in PDS when single and multiple sensor failures were encountered. It was observed that the new algorithm successfully localized the faults for all the three cases. Consequently, significant reductions were noticed in the amount of data that was sent to the cloud server. In the end, a comparison study of a proposed solution was performed with existing methods to further highlight the benefits of our technique.
High conversion gain is often required for the grid integration of renewable energy resources such as PV, fuel cells, and wind. It is desired that the stress across switches is lower when higher voltage gain is attained. Similarly, it is also preferred that the converter can achieve high voltage gain without operating at higher duty cycle values. This article presents a novel high-gain CUK converter (HGCC) that uses voltage-multiplier units. The HGCC is a combination of a modified CUK converter and voltage-multiplier units (VMUs). The converter utilizes a boost converter as an input to the modified CUK converter, resulting in an increase in the gain value. The voltage gain of HGCC is increased further by placing VMUs. Based on its overall design, the HGCC inherits various advantages of the CUK converter, such as continuous input and output current, resulting in low input and output current ripples. A mathematical model is developed for the HGCC, which helps calculate its voltage gain at different stages. The model is developed considering ideal elements without conduction and switching losses. Generalized equations for output voltage and gain are derived for level converter. A simulation study was performed in MATLAB/Simulink that further highlights the advantages of the HGCC. Voltage stresses across different components and the switching of MOSFET and diodes are studied in simulations. An experimental setup is established for hardware prototyping of the converter and validation with the simulation and Mathematical models.