Amged Abdelatif

Dr. Amged Abdelatif

University of Khartoum, Sudan
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Tunnelling and Underground Space Technology
Verified
Journal Article
Open access
AFAndrea Franza
Andrea Franza
AMAlec M. Marshall
Alec M. Marshall
THTwana Haji
Twana Haji
Amged AbdelatifAmged Abdelatif
Amged Abdelatif
Sandro CarbonariSandro Carbonari
Sandro Carbonari
Michele MoriciMichele Morici
Michele Morici
In urban areas, engineers often need to assess tunnelling-induced displacements of piled structures and the resulting potential for damage. This paper presents an elastic study of tunnel-pile-structure interaction through Winkler-based Two-Stage Analysis Methods (TSAMs), focusing on structural displacements resulting from tunnel excavation beneath piled frames or simple equivalent beams. Comparison of results with 3D finite element analyses shows that the simple TSAM models are able to provide a good assessment of tunnelling-induced building displacements. Parametric analyses highlight the role of tunnel-pile interaction and the superstructure (stiffness, configuration, and pile-structure connections) in the global response of the tunnel-soil-building system. In particular, the effect that key parameters have on deflection ratios and horizontal strains are investigated. Results illustrate how piled foundations increase the risk of structural damage compared to shallow foundations, whereas structural stiffness can reduce building deformations. Flexural deformations are predominately induced by tunnel excavations beneath piles whereas horizontal strains at the ground level are negligible when a continuous foundation is included. Furthermore, it is illustrated that results based on buildings modelled as equivalent beams can differ considerably compared to when they are modelled as framed structures. Simple design charts are provided to estimate horizontal strains and deflection ratio modification factors based on newly defined relative axial and bending stiffness parameters which account for the presence of the piles

1 February 2015 in Finite Elements in Analysis and Design
Verified
Journal Article
Open access
Amged AbdelatifAmged Abdelatif
Amged Abdelatif
John OwenJohn Owen
John Owen
MHM.F.M. Hussein
M.F.M. Hussein
Three models were developed to simulate the transfer of prestress force from steel to concrete in pre-tensioned concrete elements. The first is an analytical model based on the thick-walled cylinder theory and considers linear material properties for both steel and concrete. The second is an axi-symmetric finite element (FE) model with linear material properties; it is used to verify the analytical model. The third model is a three dimensional nonlinear FE model. This model considers the post-cracking behaviour of concrete as well as concrete shrinkage and the time of prestress releasing. A new expression from the analytical model is developed to estimate the transmission length as well as the stress distribution along the tendon. The paper also presents a parametric study to illustrate the impact of diameter of prestressing steel, concrete cover, concrete strength, initial prestress, section size, surface roughness of prestressing steel, time of prestress release, and the member length on the transfer of stress in pre-tensioned concrete elements

21 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Zafar KhanZafar Khan
Zafar Khan
Muhammad ImranMuhammad Imran
Muhammad Imran
Abdullah AltamimiAbdullah Altamimi
Abdullah Altamimi
Ogheneruona DiemuodekeOgheneruona Diemuodeke
Ogheneruona Diemuodeke
Amged AbdelatifAmged Abdelatif
Amged Abdelatif
In addition to zero-carbon generation, the plummeting cost of renewable energy sources (RES) is enabling the increased use of distributed-generation sources. Although the RES appear to be a cheaper source of energy, without the appropriate design of the RES with a true understanding of the nature of the load, they can be an unreliable and expensive source of energy. Limited research has been aimed at designing small-scale hybrid energy systems for irrigation pumping systems, and these studies did not quantify the water requirement, or in turn the energy required to supply the irrigation water. This paper provides a comprehensive feasibility analysis of an off-grid hybrid renewable energy system for the design of a water-pumping system for irrigation applications in Sudan. A systematic and holistic framework combined with a techno-economic optimization analysis for the planning and design of hybrid renewable energy systems for small-scale irrigation water-pumping systems is presented. Different hybridization cases of solar photovoltaic, wind turbine and battery storage at 12 different sites in Sudan are simulated, evaluated, and compared, considering the crop water requirement for different crops, the borehole depth, and the stochasticity of renewable energy resources. Soil, weather, and climatic data from 12 different sites in Sudan were used for the case studies, with the key aim to find the most robust and reliable solution with the lowest system cost. The results of the case studies suggest that the selection of the system is highly dependent on the cost, the volatility of the wind speed, solar radiation, and the size of the system; at present, hybridization is not the primary option at most of sites, with the exception of two. However, with the reduction in price of wind technology, the possibility of hybrid generation will rise.

4 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Zafar KhanZafar Khan
Zafar Khan
Muhammad ImranMuhammad Imran
Muhammad Imran
Jamal UmerJamal Umer
Jamal Umer
SASaeed Ahmed
Saeed Ahmed
Ogheneruona DiemuodekeOgheneruona Diemuodeke
Ogheneruona Diemuodeke
Amged AbdelatifAmged Abdelatif
Amged Abdelatif
Climate change is changing global weather patterns, with an increase in droughts expected to impact crop yields due to water scarcity. Crops can be provided with water via underground pumping systems to mitigate water shortages. However, the energy required to pump water tends to be expensive and hazardous to the environment. This paper explores different sites in Sudan to assess the crop water requirements as the first stage of developing renewable energy sources based on water pumping systems. The crop water requirements are calculated for different crops using the CROPWAT and CLIMWAT simulation tools from the Food and Agriculture Organization (FAO) of the United Nations. Further, the crop water requirements are translated into electrical energy requirements. Accurate calculations of the energy needed will help in developing cost-effective energy systems that can help in improving yields and reducing carbon emissions. The results suggest that the northern regions tend to have higher energy demands and that the potential for renewable energy should be explored in these regions, which are more susceptible to drought and where crops tend to be under higher stress due to adverse climate conditions.

1 April 2018 in Construction and Building Materials
Verified
Journal Article
Closed access
Amged AbdelatifAmged Abdelatif
Amged Abdelatif
JOJoško Ožbolt
Joško Ožbolt
SGSerena Gambarelli
Serena Gambarelli

1 December 2017 in Journal of Structural Engineering
Verified
Journal Article
Closed access
Amged AbdelatifAmged Abdelatif
Amged Abdelatif
John OwenJohn Owen
John Owen
Mohammed HusseinMohammed Hussein
Mohammed Hussein
The contribution of ruptured tendons to the residual strength of bonded posttensioned concrete structures is currently assessed based on pretensioned concrete bond models. However, this approach is inaccurate due to the inherent differences between pretensioned and posttensioned concrete. In this paper, a nonlinear three-dimensional (3D) finite-element model is developed for the reanchoring of a ruptured tendon in posttensioned concrete. The model is validated using full-field displacement measurement from 33 posttensioned concrete prisms and previous experimental data on beams from the literature. The influence of different parameters is investigated, including tendon properties (i.e., diameter, roughness), duct properties (i.e., diameter, thickness, material), initial prestress, concrete strength, grout strength, grout voids, stirrups, and strands on the tendon reanchorage. The most influential parameters are found to be tendon and duct properties.