Deivis Plaušinaitis

Prof. Deivis Plaušinaitis

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Vilma RatautaiteVilma Ratautaite
Vilma Ratautaite
UPURTE PRENTICE
URTE PRENTICE
Deivis PlaušinaitisDeivis Plaušinaitis
Deivis Plaušinaitis
RBRaimonda Boguzaite
Raimonda Boguzaite
DBDomas Balčiūnas
Domas Balčiūnas
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
The review focuses on the overview of electrochemical sensors based on molecularly imprinted polymers (MIPs) for the determination of uric acid. The importance of robust and precise determination of uric acid is highlighted, a short description of the principles of molecular imprinting technology is presented, and advantages over the others affinity-based analytical methods are discussed. The review is mainly concerned with the electro-analytical methods like cyclic voltammetry, electrochemical impedance spectroscopy, amperometry, etc. Moreover, there are some scattered notes to the other electrochemistry-related analytical methods, which are capable of providing additional information and to solve some challenges that are not achievable using standard electrochemical methods. The significance of these overviewed methods is highlighted. The overview of the research that is employing MIPs imprinted with uric acid is mainly targeted to address these topics: (i) type of polymers, which are used to design uric acid imprint structures; (ii) types of working electrodes and/or other parts of signal transducing systems applied for the registration of analytical signal; (iii) the description of the uric acid extraction procedures applied for the design of final MIP-structure; (iv) advantages and disadvantages of electrochemical methods and other signal transducing methods used for the registration of the analytical signal; (vi) overview of types of interfering molecules, which were analyzed to evaluate the selectivity; (vi) comparison of analytical characteristics such as linear range, limits of detection and quantification, reusability, reproducibility, repeatability, and stability. Some insights in future development of uric acid sensors are discussed in this review.

1 April 2018 in Science of The Total Environment
Verified
Journal Article
Closed access
Deivis PlaušinaitisDeivis Plaušinaitis
Deivis Plaušinaitis
APAleksandr Prokopchik
Aleksandr Prokopchik
AKAlgimantas Karaliunas
Algimantas Karaliunas
LBLeonid Bohdan
Leonid Bohdan
YBYuliya Balashevska
Yuliya Balashevska

26 March 2026 in Polymers
Verified
Journal Article
Open access
PDF file
GKGreta Kaspute
Greta Kaspute
Deivis PlaušinaitisDeivis Plaušinaitis
Deivis Plaušinaitis
Vilma RatautaiteVilma Ratautaite
Vilma Ratautaite
EVEvelina Vaicekauskaite
Evelina Vaicekauskaite
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
UPURTE PRENTICE
URTE PRENTICE
Molecularly imprinted polymers (MIPs) are widely employed for selective adsorption of target molecules in sensing and separation applications. The architecture of MIP films can influence adsorption behavior, interfacial stability, and reusability, yet systematic investigations of these effects are limited. This study aimed to evaluate how different polypyrrole (PPy) MIP film architectures affect the adsorption, stability, and regeneration characteristics of geraniol-imprinted layers on gold electrodes. Geraniol-imprinted and non-imprinted PPy films were electropolymerized onto quartz crystal microbalance (QCM) substrates. Two film architectures were compared: (i) a single-layer geraniol-imprinted PPy film, and (ii) a double-layer film consisting of a non-imprinted PPy underlayer followed by a geraniol-imprinted layer. Film characterization was performed using cyclic voltammetry (CV) and electrochemical quartz crystal microbalance (EQCM) measurements. Adsorption–desorption cycles were conducted to assess mass uptake, signal stability, and regeneration performance. EQCM analysis revealed that the double-layer architecture exhibited enhanced frequency signal stability during repeated adsorption–desorption cycles compared to single-layer films, suggesting a stabilizing effect of the underlying non-imprinted PPy layer at the electrode interface. Geraniol-imprinted films demonstrated significantly higher mass uptake than non-imprinted controls, confirming the sensitivity provided by molecular imprinting. Single-layer films showed more variability in signal response and less consistent regeneration performance. The architecture of MIP films significantly affects adsorption behavior, stability, and regeneration on electrode surfaces. Incorporating a non-imprinted PPy underlayer can improve signal reproducibility and enhance the robustness of MIP-based sensing interfaces. These findings provide guidance for the rational design of MIP coatings for electrochemical sensors and QCM-active platforms.

23 February 2018 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
Deivis PlaušinaitisDeivis Plaušinaitis
Deivis Plaušinaitis
BKBirute Knasiene
Birute Knasiene
APAleksandr Prokopchik
Aleksandr Prokopchik
ENEvaldas Naujalis
Evaldas Naujalis
ACAdrián Vicent Claramunt
Adrián Vicent Claramunt

Verified
Journal Article
Open access
PDF file
GKGreta Kaspute
Greta Kaspute
Deivis PlaušinaitisDeivis Plaušinaitis
Deivis Plaušinaitis
Vilma RatautaiteVilma Ratautaite
Vilma Ratautaite
EVEvelina Vaicekauskaite
Evelina Vaicekauskaite
Vytautas BucinskasVytautas Bucinskas
Vytautas Bucinskas
UPURTE PRENTICE
URTE PRENTICE
To develop molecularly imprinted polymer (MIP)-based biosensors effectively, it is necessary to evaluate the potential adsorption of materials onto the electrode surface. Therefore, we investigated the adsorption of geraniol and pyrrole and compared them. In addition to determining adsorption constants, particular focus was placed on adsorption mechanisms, as they directly influence monolayer or multilayer formation, template removal efficiency, and the selectivity of the final imprinted structure. To achieve this, we employed various electrochemical methods, including cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and quartz crystal microbalance (QCM) measurements. Measurements were repeated to ensure reliability. The findings were used to calculate adsorption constants using the Langmuir equation. Geraniol and pyrrole showed adsorption constants of 21.5 L/mol and 31.7 L/mol, respectively, indicating strong molecular interactions. These results indicate strong interactions between the two molecules, suggesting that geraniol influences electrode polymerization. This led to the importance of proper surface preparation, evaluation of analyte–monomer interactions, and the opportunity to reuse materials.

3 January 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
JSJulija Sarvutiene
Julija Sarvutiene
Deivis PlaušinaitisDeivis Plaušinaitis
Deivis Plaušinaitis
Vytautas BucinskasVytautas Bucinskas
Vytautas Bucinskas
Simonas RamanavičiusSimonas Ramanavičius
Simonas Ramanavičius
ARAlma Rucinskiene
Alma Rucinskiene
UPURTE PRENTICE
URTE PRENTICE
The reusability of enzymes is a fundamental aspect of sustainable biotechnology and the development of biosensors. This study presents one of the first quantitative evaluations of DNA polymerase reusability by utilizing integrated quartz crystal microbalance (QCM) kinetics and real-time monitoring of exonuclease activity. The results showed that immobilized T7 DNA polymerase retained approximately 50% of its initial activity after three 90-min cycles and around 20% after five cycles. Significantly lower activities were observed for shorter, 45-min cycles. This indicates an unexpected time-dependent enhancement in stability for longer reaction times. The findings suggest a promising trend in enzyme stability and reusability, establishing a quantitative relationship between reaction duration and enzyme performance. This relationship offers a scalable pathway for the regeneration of biosensors and for sustainable enzymatic catalysis. Additionally, the work provides a transferable framework that can be applied to other DNA-processing enzymes, which supports long-term biosensor performance and industrial biocatalysis. The demonstrated approach offers a transferable and scalable methodology for the development of reusable polymerase-based biosensors and sustainable biocatalytic systems.