This survey presents a thorough overview of the main types of biomaterials used for the manufacturing of implants. The use of different materials for the creation and refinement of medical devices aims at optimizing their properties and raising the level of safety for the patients. The purpose of the study is to classify the most common bulk materials used in medicine according to their nature, interaction with the host tissues and their function in the organisms. Some important advantages and disadvantages of the different classes of implant materials are considered. In the last few years there is a strong tendency toward the surface modification of biomedical devices. Various trends in processing of the materials are focused on increasing their corrosion resistance, wear resistance, biocompatibility and microbiological properties.
The hydrophobic azo dye 6-hexyl-4-(2-thiazolylazo)resorcinol (HTAR, H2L) was studied as part of a system for the centrifuge-less cloud point extraction (CL-CPE) and spectrophotometric determination of traces of cobalt. The extracted 1:2 (Co:HTAR) complex, [CoIII(HL−)(L2−)]0, shows an absorption maximum at 553 nm and contains HTAR in two different acid–base forms. Optimum conditions for its formation and CL-CPE were found as follows: 1 × 10−5 mol L−1 of HTAR, 1.64% of Triton X-114, pH of 7.8, incubation time of 20 min at ca. 50 °C, and cooling time of 30 min at ca. −20 °C. The linear range, limit of detection, and apparent molar absorptivity coefficient were 5.4–189 ng mL−1, 1.64 ng mL−1, and 2.63 × 105 L mol−1 cm−1, respectively. The developed procedure does not use any organic solvents and can be described as simple, cheap, sensitive, convenient, and environmentally friendly. It was successfully applied to the analysis of artificial mixtures and real samples, such as steel, dental alloy, rainwater, ampoules of vitamin B12, and saline solution for intravenous infusion.
The incessant need for the elimination of pathogenic viruses and multi-drug resistant bacteria has been a critical issue during recent decades, and requires the creation of new antimicrobial materials. Our study describes the production of silver-modified anodic alumina substrates by two methods, and estimation of their bactericidal activity. Aluminum oxide coatings were obtained via an anodization process of low-purity aluminum in an acidic bath for different time periods. The realization of silver infiltration into the pores of the alumina layers was carried out employing two different routes—electrochemical deposition, and in situ thermal reduction. The obtained films were characterized using scanning electron microscopy (SEM). Changes in the surface morphology and thickness of the initial oxide structures after hot water sealing procedure were observed. The presence of silver inside the pores of the alumina layers was also assessed. It was found that silver electrodeposition resulted in greater surface saturation. Large silver accumulations were observed on the thinner anodic films which experienced electroplating for longer time periods. Finally, the antibacterial activity of the modified alumina structures against Gram-negative (Escherichia coli) and Gram-positive (Bacillus cereus) bacteria was evaluated. The results demonstrate that silver deposits acquired by the electrochemical technique improve the bactericidal efficiency of the anodic aluminum oxide (AAO) layers. On the contrary, alumina structures with chemically embedded Ag particles did not show significant antibacterial properties. Overall, the present studies demonstrate that biological activity of silver-doped AAO films depends on the techniques used for their modification.
A novel centrifuge-less cloud point extraction (CL-CPE) method was developed for the spectrophotometric determination of copper(II) using 4-nitrocatechol (4NC) as the chelating agent. The extraction system utilizes a mixed micellar phase composed of the nonionic surfactant Triton X-114 and the ionic liquid (IL) Aliquat® 336 (A336). The extracted ternary ion-association complex, identified as (A336+)2[Cu(4NC)2], exhibits a maximum absorbance at 451 nm, with a molar absorption coefficient of 8.9 × 104 M−1 cm−1 and a Sandell’s sensitivity of 0.71 ng cm−2. The method demonstrates a linear response in the copper(II) concentration range of 32–763 ng mL−1 and a limit of detection of 9.7 ng mL−1. The logarithmic extraction constant (log Kex) was determined to be 7.9, indicating efficient extraction. Method performance, evaluated by the Blue Applicability Grade Index (BAGI) and the Click Analytical Chemistry Index (CACI), confirmed its feasibility, practicality, simplicity, convenience, cost-effectiveness, environmental friendliness, and analytical competitiveness. The proposed IL-CL-CPE method was successfully applied to the analysis of a dietary supplement, a solution for infusion, and synthetic mixtures simulating various copper alloys.
Introduction: The use of diverse materials for medical purposes is continuously expanding. The modification of materials which are routinely applied in medical practice as well as the development and introduction of new materials require studies on their biological activity. The first steps in this process are the preliminary short-term screening tests for cytotoxicity and biocompatibility performed on cell cultures. Methods: Coating of stainless steel (316 L) scaffolds with chromium-cobalt was performed by electroplating using the non-standard electrolyte Chromispel. The process was carried through at different cathode current densities and deposition times. The modified surface of the metal scaffolds was studied for cytoxicity and cell vitality on the serum-free McCoy-Plovdiv and the immortalized PDL cell cultures. Results: Our results indicate no cytotoxic effect of the coated metal scaffolds. Even more, three of the samples stimulated the proliferation and growth of McCoy-Plovdiv cells. Conclusion: We have strong reasons to believe that chromium-cobalt coatings are promising for future studies and reliable for medical purposes.