Mohamed Waly

Dr. Mohamed Waly

Department of Medical Equipment Technology, College of Applied Medical Sciences Majmaah University, Al Majmaah 11952 - Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2020 in IEEE Access
Verified
Journal Article
Open access
ASAMOR SMIDA
AMOR SMIDA
AIAmjad Iqbal
Amjad Iqbal
AAAbdullah Alazemi
Abdullah Alazemi
MWMohamed Waly
Mohamed Waly
Ridha GhayoulaRidha Ghayoula
Ridha Ghayoula
SKSunghwan Kim
Sunghwan Kim
This paper presents a wideband, low-profile and semi-flexible antenna for wearable biomedical telemetry applications. The antenna is designed on a semi-flexible material of RT/duroid 5880 (r = 2.2, tanδ = 0.0004) with an overall dimensions of 17 mm × 25 mm × 0.787 mm (0.2λ∘×0.29λ∘×0.009λ∘). A conventional rectangular patch is modified by adding rectangular slots to lower the resonant frequency, and the partial ground plane is modified to enhance the operational bandwidth. The final antenna model operates at 2.4 GHz with a 10-dB bandwidth (fractional bandwidth) of 1380 MHz (59.7 % at the centre frequency of 2.4 GHz). The proposed antenna maintains high gain (2.50 dBi at 2.4 GHz) and efficiency (93 % at 2.4 GHz). It is proved from the simulations and experimental results that the antenna has negligible effects in terms of reflection coefficient, bandwidth, gain, and efficiency when it is bent. Moreover, the antenna is simulated and experimentally tested in proximity of the human body, which shows good performance. The proposed wideband antenna is a promising candidate for compact wearable biomedical devices.

17 January 2020 in IEEE Access
Verified
Journal Article
Open access
AIAmjad Iqbal
Amjad Iqbal
ASAMOR SMIDA
AMOR SMIDA
AAAbdullah Alazemi
Abdullah Alazemi
MWMohamed Waly
Mohamed Waly
NMNazih Khaddaj Mallat
Nazih Khaddaj Mallat
SKSunghwan Kim
Sunghwan Kim
This paper presents a miniaturized circularly polarized multiple-input multiple-output (MIMO) antenna for wearable biotelemetric devices. The proposed MIMO antenna consists of four elements, which are placed orthogonally to the adjacent elements. The proposed antenna has a wideband response [10-dB bandwidth of 2210 MHz (fractional bandwidth (FBW) = 92.08%) in free space and 10-dB bandwidth of 2200 MHz (FBW = 91.66%) when worn on human-body], this frequency range covers the important and unlicensed industrial, scientific and medical (ISM) band (2.40-2.48 GHz). The antenna exhibits a wideband 3-dB circularly polarized bandwidth of 1300 MHz (FBW=54.16%) and 1040 MHz (FBW=43.33%) in free space and when worn on the body, respectively. The optimized antenna in free space (on-body) has an envelop correlation coefficient (ECC) less than 0.21 (0.23), a diversity gain (DG) greater than 9.77 dB (9.71 dB), a multiplexing efficiency (ME) greater than -0.85 dB (-0.63 dB), and a channel capacity loss (CCL) less than 0.13 bps/Hz (0.13 bps/Hz). The stable radiation, high gain, high efficiency, and good MIMO properties in free space and on human-body make the proposed antenna a suitable choice for use in high data wearable biotelemetric devices.

15 December 2022 in PeerJ
Verified
Journal Article
Open access
PDF file
Mohamed Sherif SirajudeenMohamed Sherif Sirajudeen
Mohamed Sherif Sirajudeen
MAMsaad Alzhrani
Msaad Alzhrani
AAAhmad Alanazi
Ahmad Alanazi
MAMazen Alqahtani
Mazen Alqahtani
MWMohamed Waly
Mohamed Waly
NANasser M. Al-Hussinan
Nasser M. Al-Hussinan
The smartphone emerges as an inevitable gadget in modern society and its increased usage results in neck disorders among its users. However, the factors associated with neck disorders among smartphone users are ambiguous and less explored in the literature. The purpose of this research was to determine the prevalence of text neck posture, smartphone addiction/overuse, and its association with neck disorders among university students in the Kingdom of Saudi Arabia during the COVID-19 pandemic. A total of 313 university students who were aged 18 years and older, owned a smartphone, and used it during the preceding 12 months participated in this cross-sectional study. A self-administered questionnaire was used to collect data regarding the prevalence of text neck posture, smartphone addiction/overuse, neck disorders, and the level of physical activity. Binary logistic regression was used to determine the association between the prevalence of neck disorders and text neck posture, smartphone addiction/overuse, and level of physical activity. The 12 months prevalence of neck disorders due to smartphone use among the participants was found to be 46%. The neck disorders were more prevalent among participants who reported text neck posture (P < 0.001) and categorized as smartphone-addicted/overuse (P < 0.001). Measures to promote the awareness of healthy use of smartphones including postural education and to decrease its screen time are warranted to reduce neck disorders.

25 November 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
Mohamed Sherif SirajudeenMohamed Sherif Sirajudeen
Mohamed Sherif Sirajudeen
MAMsaad Alzhrani
Msaad Alzhrani
AAAhmad Alanazi
Ahmad Alanazi
MAMazen Alqahtani
Mazen Alqahtani
MWMohamed Waly
Mohamed Waly
MMMohammad Miraj
Mohammad Miraj
This study aimed to investigate the prevalence of upper limb musculoskeletal disorders (MSDs) and their association with smartphone addiction and smartphone usage among university students in the Kingdom of Saudi Arabia during the COVID-19 pandemic. A total of 313 university students aged 18 years and older who owned a smartphone and used it during the preceding 12 months participated in this cross-sectional study. The prevalence of upper limb MSDs, smartphone addiction/overuse, and levels of physical activity were recorded using the standardized Nordic musculoskeletal questionnaire, the smartphone addiction scale (short version), and the international physical activity questionnaire (short form), respectively. Data collection was performed on campus between March and May 2021. Binary logistic regression was used to determine the association between the prevalence of upper limb MSDs and smartphone addiction/overuse and levels of physical activity. The 12-month prevalence of MSDs of the shoulder, elbow, and wrist/hand regions due to smartphone use among participants was found to be 20.13%, 5.11%, and 13.42%, respectively. Shoulder (odds ratio (OR) = 11.39, 95% confidence interval (CI) = 4.64–27.94, p < 0.001), elbow (OR = 15.38, 95% CI = 1.92–123.26, p = 0.01), and wrist/hand MSDs (OR = 7.65, 95% CI = 2.75–21.22, p < 0.001) were more prevalent among participants who were categorized as having smartphone addiction/overuse measures. Promoting awareness about the healthy use of smartphones, including postural education and decreasing screen time, is necessary to reduce smartphone-related MSDs.

1 December 2020 in Results in Physics
Verified
Journal Article
Open access
MAMuhammad Azam
Muhammad Azam
FMFazle Mabood
Fazle Mabood
TXTianzhou Xu
Tianzhou Xu
MWMohamed Waly
Mohamed Waly
ITIskander Tlili
Iskander Tlili

29 July 2024 in IEEE Access
Verified
Journal Article
Open access
MWMohamed Waly
Mohamed Waly
JSJamel A.S SMIDA
Jamel A.S SMIDA
MBMohsen Bakouri
Mohsen Bakouri
BABakheet Awad Alresheedi
Bakheet Awad Alresheedi
TATariq Mohammed Alqahtani
Tariq Mohammed Alqahtani
ASAMOR SMIDA
AMOR SMIDA
This study introduces an innovative and compact wearable Long-Range (LoRa) patch antenna developed for monitoring vital signs, with a focus on heart rate and body temperature, in medical applications of Wireless Body Area Networks (WBAN). The antenna functions within the 868 MHz and 915 MHz LoRa bands, filling a notable gap in current literature regarding compact, wearable antennas operating below 1 GHz. Fabricated on a Rogers Duroid RO3003™ substrate, the antenna incorporates a U-slot on a conventional rectangular patch, a matching stub, and a partial ground plane to enhance impedance matching and performance efficiency. Furthermore, the antenna displays a bidirectional radiation pattern in the E -plane and an omnidirectional pattern in the H -plane at both frequencies, achieving a peak gain of 2.12 dBi and a radiation efficiency of 99.8% at 868 MHz. The antenna, measuring 80×60mm 2 (0.23 λ 0 × 0.17 λ 0 ), was designed, simulated, and optimized using CST Microwave Studio (MWS) software. The performance under bending conditions was also assessed, revealing a bending an excellent efficiency with minimal impact on bandwidth and gain. Specific Absorption Rate (SAR) analysis indicated that all values were within the safety limits set by FCC and ICNIRP standards. Supervised regression machine learning models, specifically the ensemble regression model, were employed to predict resonance frequencies based on various antenna parameters, resulting in an R-squared score of 87.68%. This approach significantly reduced the computational time required for full-wave simulations, streamlining the design process. Real-world experimental validation involved open-field testing of the fabricated prototype for WBAN LoRa applications. The performance, evaluated on a LoRa transceiver system utilizing the LoRa SX1276, demonstrated the superior capabilities of the proposed antenna in heart rate and temperature monitoring, with an average RSSI improvement of -5 dBm at various points within a range of up to 1 km. This confirmed its improved signal transmission and reception capabilities in vital sign monitoring. The proposed antenna shows strong performance metrics and significant potential for WBAN in long-range applications, as evidenced by thorough experimental validations.