Sunghwan Kim

Prof. Sunghwan Kim

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
MAMohammed H. Alsharif
Mohammed H. Alsharif
HAHilary Anabi
Hilary Anabi
PAProf. Mahmoud A. M. Albreem
Prof. Mahmoud A. M. Albreem
Shehzad Ashraf ChaudhryShehzad Ashraf Chaudhry
Shehzad Ashraf Chaudhry
MZM. Sultan Zia
M. Sultan Zia
SKSunghwan Kim
Sunghwan Kim
The standardization activities of the fifth generation communications are clearly over and deployment has commenced globally. To sustain the competitive edge of wireless networks, industrial and academia synergy have begun to conceptualize the next generation of wireless communication systems (namely, sixth generation, (6G)) aimed at laying the foundation for the stratification of the communication needs of the 2030s. In support of this vision, this study highlights the most promising lines of research from the recent literature in common directions for the 6G project. Its core contribution involves exploring the critical issues and key potential features of 6G communications, including: (i) vision and key features; (ii) challenges and potential solutions; and (iii) research activities. These controversial research topics were profoundly examined in relation to the motivation of their various sub-domains to achieve a precise, concrete, and concise conclusion. Thus, this article will contribute significantly to opening new horizons for future research directions.

8 August 2019 in IEEE Access
Verified
Journal Article
Open access
AIAmjad Iqbal
Amjad Iqbal
ABAbdul Basir
Abdul Basir
ASAmor Smida
Amor Smida
NMNazih Khaddaj Mallat
Nazih Khaddaj Mallat
Issa ElferganiIssa Elfergani
Issa Elfergani
SKSunghwan Kim
Sunghwan Kim
A millimeter-wave (mm-Wave) multiple input multiple output (MIMO) antenna operating at 24 GHz (ISM band), suitable for wearable applications, is proposed in this paper. The proposed MIMO antenna consists of two elements, designed with an edge-to-edge distance of 5.14 mm, backed by a $5\times 5$ cell electromagnetic bandgap (EBG) structure. The antenna is fabricated on a flexible Rogers 6002 material ( $\epsilon _{r}=$ 2.94 , tan $\delta =$ 0.0012 , thickness = 0.254 mm ). The proposed antenna retains its performance when bent along the x-axis and y-axis. The performance of the antenna in term of s-parameters and radiation properties is studied in free space as well as on a human phantom. Good impedance matching of the antenna at the resonating frequency (24 GHz) is observed when it is bent and when worn on the body. The introduction of the EBG improves the gain by 1.9 dBi, reduces the backward radiation by 8 dB, reduces the power density on the back towards the body from > 200 W/m 2 to < 10 W/m 2 , and also enhances the 10 dB bandwidth by 100 MHz. The antenna possesses a low envelope correlation coefficient (ECC) of 0.24, high diversity gain (DG) of 9.7 dB, reasonable multiplexing efficiency of −0.684 dB and a good peak gain of 6 dBi at 24 GHz. The proposed antenna is suitable for wearable applications at mm-Wave range due to its simple geometry and good performance in bending and on-body worn scenarios.

17 January 2020 in IEEE Access
Verified
Journal Article
Open access
ASAMOR SMIDA
AMOR SMIDA
AIAmjad Iqbal
Amjad Iqbal
AAAbdullah Alazemi
Abdullah Alazemi
MWMohamed Waly
Mohamed Waly
Ridha GhayoulaRidha Ghayoula
Ridha Ghayoula
SKSunghwan Kim
Sunghwan Kim
This paper presents a wideband, low-profile and semi-flexible antenna for wearable biomedical telemetry applications. The antenna is designed on a semi-flexible material of RT/duroid 5880 (r = 2.2, tanδ = 0.0004) with an overall dimensions of 17 mm × 25 mm × 0.787 mm (0.2λ∘×0.29λ∘×0.009λ∘). A conventional rectangular patch is modified by adding rectangular slots to lower the resonant frequency, and the partial ground plane is modified to enhance the operational bandwidth. The final antenna model operates at 2.4 GHz with a 10-dB bandwidth (fractional bandwidth) of 1380 MHz (59.7 % at the centre frequency of 2.4 GHz). The proposed antenna maintains high gain (2.50 dBi at 2.4 GHz) and efficiency (93 % at 2.4 GHz). It is proved from the simulations and experimental results that the antenna has negligible effects in terms of reflection coefficient, bandwidth, gain, and efficiency when it is bent. Moreover, the antenna is simulated and experimentally tested in proximity of the human body, which shows good performance. The proposed wideband antenna is a promising candidate for compact wearable biomedical devices.

17 January 2020 in IEEE Access
Verified
Journal Article
Open access
AIAmjad Iqbal
Amjad Iqbal
ASAMOR SMIDA
AMOR SMIDA
AAAbdullah Alazemi
Abdullah Alazemi
MWMohamed Waly
Mohamed Waly
NMNazih Khaddaj Mallat
Nazih Khaddaj Mallat
SKSunghwan Kim
Sunghwan Kim
This paper presents a miniaturized circularly polarized multiple-input multiple-output (MIMO) antenna for wearable biotelemetric devices. The proposed MIMO antenna consists of four elements, which are placed orthogonally to the adjacent elements. The proposed antenna has a wideband response [10-dB bandwidth of 2210 MHz (fractional bandwidth (FBW) = 92.08%) in free space and 10-dB bandwidth of 2200 MHz (FBW = 91.66%) when worn on human-body], this frequency range covers the important and unlicensed industrial, scientific and medical (ISM) band (2.40-2.48 GHz). The antenna exhibits a wideband 3-dB circularly polarized bandwidth of 1300 MHz (FBW=54.16%) and 1040 MHz (FBW=43.33%) in free space and when worn on the body, respectively. The optimized antenna in free space (on-body) has an envelop correlation coefficient (ECC) less than 0.21 (0.23), a diversity gain (DG) greater than 9.77 dB (9.71 dB), a multiplexing efficiency (ME) greater than -0.85 dB (-0.63 dB), and a channel capacity loss (CCL) less than 0.13 bps/Hz (0.13 bps/Hz). The stable radiation, high gain, high efficiency, and good MIMO properties in free space and on human-body make the proposed antenna a suitable choice for use in high data wearable biotelemetric devices.

18 March 2020 in IEEE Access
Verified
Journal Article
Open access
BKBilal Khan
Bilal Khan
Rashid NaseemRashid Naseem
Rashid Naseem
FMFazal Muhammad
Fazal Muhammad
Ghulam AbbasGhulam Abbas
Ghulam Abbas
SKSunghwan Kim
Sunghwan Kim
Chronic Kidney Disease (CKD) implies that the human kidneys are harmed and unable to blood filter in the manner which they should. The disease is designated "chronic" in light of the fact that harm to human kidneys happen gradually over a significant time. This harm can make wastes to build up in your body. Many techniques and models have been developed to diagnos the CKD in early-stage. Among all techniques, Machine Learning (ML) techniques play a significant role in the early forecasting of different kinds ailments. ML techniques have been used for achieving analytical results which is one of the instruments utilize in medical analysis and prediction. In this paper, we employ experiential analysis of ML techniques for classifying the kidney patient dataset as CKD or NOTCKD. Seven ML techniques together with NBTree, J48, Support Vector Machine, Logistic Regression, Multi-layer Perceptron, Naïve Bayes, and Composite Hypercube on Iterated Random Projection (CHIRP) are utilized and assessed using distinctive evaluation measures such as mean absolute error (MAE), root mean squared error (RMSE), relative absolute error (RAE), root relative squared error (RRSE), recall, precision, F-measure and accuracy.The experimental outcomes accomplished of MAE are 0.0419 for NB, 0.035 for LR, 0.265 for MLP, 0.0229 for J48, 0.015 for SVM, 0.0158 for NBTree and 0.0025 for CHIRP. Moreover, experimental results using accuracy revealed 95.75% for NB, 96.50% for LR, 97.25% for MLP, 97.75% for J48, 98.25% for SVM, 98.75% for NBTree, and 99.75% for CHIRP. The overall outcomes show that CHIRP performs well in terms of diminishing error rates and improving accuracy.

9 February 2012 in Sensors
Verified
Journal Article
Open access
PDF file
SYSeokhoon Yoon
Seokhoon Yoon
MAMd Abul Kalam Azad
Md Abul Kalam Azad
HOHoon Oh
Hoon Oh
SKSunghwan Kim
Sunghwan Kim
Deploying a multi-hop underwater acoustic sensor network (UASN) in a large area brings about new challenges in reliable data transmissions and survivability of network due to the limited underwater communication range/bandwidth and the limited energy of underwater sensor nodes. In order to address those challenges and achieve the objectives of maximization of data delivery ratio and minimization of energy consumption of underwater sensor nodes, this paper proposes a new underwater routing scheme, namely AURP (AUV-aided underwater routing protocol), which uses not only heterogeneous acoustic communication channels but also controlled mobility of multiple autonomous underwater vehicles (AUVs). In AURP, the total data transmissions are minimized by using AUVs as relay nodes, which collect sensed data from gateway nodes and then forward to the sink. Moreover, controlled mobility of AUVs makes it possible to apply a short-range high data rate underwater channel for transmissions of a large amount of data. To the best to our knowledge, this work is the first attempt to employ multiple AUVs as relay nodes in a multi-hop UASN to improve the network performance in terms of data delivery ratio and energy consumption. Simulations, which are incorporated with a realistic underwater acoustic communication channel model, are carried out to evaluate the performance of the proposed scheme, and the results indicate that a high delivery ratio and low energy consumption can be achieved.