7 October 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
KLKye-Sung Lee
Kye-Sung Lee
PMPanomsak Meemon
Panomsak Meemon
JRJannick P. Rolland
Jannick P. Rolland
We analyze the three most common profiles of scanning functions for galvanometer-based scanners (GSs): the sawtooth, triangular and sinusoidal functions. They are determined experimentally with regard to the scan parameters of the input signal (i.e., frequency and amplitude). We study the differences of the output function of the GS measured as the positional error of the oscillatory mirror from the ideal function given by the input signal of the device. The limits in achieving the different types of scanning functions in terms of duty cycle and linearity are determined experimentally for the possible range of scan parameters. Of particular importance are the preservation of an imposed duty cycle and profile for the sawtooth function, the quantification of the linearity for the sinusoidal function, and the effective duty cycle for the triangular, as well as for the other functions. The range of scan amplitudes for which the stability of the oscillatory regime of the galvo mirror is stable for different frequencies is also highlighted. While the use of the device in certain scanning regimes is studied, certain rules of thumb are deduced to make the best out of the galvoscanner. Finally, the three types of scanning functions are tested with a Fourier domain optical coherence tomography (FD OCT) setup and the conclusions of the study are demonstrated in an imaging application by correlating the determined limits of the scanning regimes with the requirements of OCT.

8 June 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
ACAndrea Cogliati
Andrea Cogliati
CCCristina Canavesi
Cristina Canavesi
AHAdam Hayes
Adam Hayes
PTPatrice Tankam
Patrice Tankam
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
JRJannick P. Rolland
Jannick P. Rolland
High-speed scanning in optical coherence tomography (OCT) often comes with either compromises in image quality, the requirement for post-processing of the acquired images, or both. We report on distortion-free OCT volumetric imaging with a dual-axis micro-electro-mechanical system (MEMS)-based handheld imaging probe. In the context of an imaging probe with optics located between the 2D MEMS and the sample, we report in this paper on how pre-shaped open-loop input signals with tailored non-linear parts were implemented in a custom control board and, unlike the sinusoidal signals typically used for MEMS, achieved real-time distortion-free imaging without post-processing. The MEMS mirror was integrated into a compact, lightweight handheld probe. The MEMS scanner achieved a 12-fold reduction in volume and 17-fold reduction in weight over a previous dual-mirror galvanometer-based scanner. Distortion-free imaging with no post-processing with a Gabor-domain optical coherence microscope (GD-OCM) with 2 μm axial and lateral resolutions over a field of view of 1 × 1 mm2 is demonstrated experimentally through volumetric images of a regular microscopic structure, an excised human cornea, and in vivo human skin.

8 June 2015 in Applied Optics
Verified
Journal Article
Open access
PDF file
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
PTPatrice Tankam
Patrice Tankam
JHJinxin Huang
Jinxin Huang
JWJungeun Won
Jungeun Won
JRJannick P. Rolland
Jannick P. Rolland
We study experimentally the effective duty cycle of galvanometer-based scanners (GSs) with regard to three main parameters of the scanning process: theoretical/imposed duty cycle (of the input signal), scan frequency, and scan amplitude. Sawtooth and triangular input signals for the device are considered. The effects of the mechanical inertia of the oscillatory element of the GS are analyzed and their consequences are discussed in the context of optical coherence tomography (OCT) imaging. When the theoretical duty cycle and the scan amplitude are increased to the limit, the saturation of the device is demonstrated for a useful range of scan frequencies by direct measurement of the position of the galvomirror. Investigations of OCT imaging of large samples also validate this saturation, as examplified by the gaps/blurred portions obtained between neighboring images when using both triangular and sawtooth scanning at high scan frequencies. For this latter aspect, the necessary overlap between neighboring B-scans, and therefore between the corresponding volumetric reconstructions of the sample, are evaluated and implemented with regard to the same parameters of the scanning process. OCT images that are free of these artifacts are thus obtained.

28 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
Ralph-Alexandru ErdelyiRalph-Alexandru Erdelyi
Ralph-Alexandru Erdelyi
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
Cosmin SinescuCosmin Sinescu
Cosmin Sinescu
GDGeorge Mihai Dobre
George Mihai Dobre
Adrian BraduAdrian Bradu
Adrian Bradu
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
A correct diagnosis in dental medicine is typically provided only after clinical and radiological evaluations. They are also required for treatment assessments. The aim of this study is to establish the boundaries from which a modern, although established, imaging technique, Optical Coherence Tomography (OCT), is more suitable than the common X-ray radiography to assess dental issues and treatments. The most common methods for daily-basis clinical imaging are utilized in this study for extracted teeth (but also for other dental samples and materials), i.e., panoramic, intraoral radiography, and three-dimensional (3D) cone beam computed tomography (CBCT). The advantages of using OCT as an imaging method in dentistry are discussed, with a focus on its superior image resolution. Drawbacks related to its limited penetration depth and Field-of-View (FOV) are pointed out. High-quality radiological investigations are performed, measurements are done, and data collected. The same teeth and samples are also imaged (mostly) with an in-house developed Swept Source (SS)-OCT system, Master-Slave enhanced. Some of the OCT investigations employed two other in-house developed OCT systems, Spectral Domain (SD) and Time Domain (TD). Dedicated toolbars from Romexis software (Planmeca, Helsinki, Finland) are used to perform measurements using both radiography and OCT. Clinical conclusions are drawn from the investigations. Upsides and downsides of the two medical imaging techniques are concluded for each type of considered diagnosis. For treatment assessments, it is concluded that OCT is more appropriate than radiography in all applications, except bone-related investigations and periodontitis that demand data from higher-penetration depths than possible with the current level of OCT technology.

8 August 2014 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
DDDorin Demian
Dorin Demian
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
CSCosmin Sinescu
Cosmin Sinescu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
RCRamona Cernat
Ramona Cernat
Adrian PodoleanuAdrian Podoleanu
Adrian Podoleanu
Three simple and low-cost configurations of handheld scanning probes for optical coherence tomography have been developed. Their design and testing for dentistry applications are presented. The first two configurations were built exclusively from available off-the-shelf optomechanical components, which, to the best of our knowledge, are the first designs of this type. The third configuration includes these components in an optimized and ergonomic probe. All the designs are presented in detail to allow for their duplication in any laboratory with a minimum effort, for applications that range from educational to high-end clinical investigations. Requirements that have to be fulfilled to achieve configurations which are reliable, ergonomic—for clinical environments, and easy to build are presented. While a range of applications is possible for the prototypes developed, in this study the handheld probes are tested ex vivo with a spectral domain optical coherence tomography system built in-house, for dental constructs. A previous testing with a swept source optical coherence tomography system has also been performed both in vivo and ex vivo for ear, nose, and throat—in a medical environment. The applications use the capability of optical coherence tomography to achieve real-time, high-resolution, non-contact, and non-destructive interferometric investigations with micrometer resolutions and millimeter penetration depth inside the sample. In this study, testing the quality of the material of one of the most used types of dental prosthesis, metalo-ceramic is thus demonstrated.

12 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
Alexandru Lucian DimbAlexandru Lucian Dimb
Alexandru Lucian Dimb
Rotational Risley prisms are one of the fastest two-dimensional (2D) optomechanical scanning systems. Their drawback is the strong non-linearity of the scan patterns they produce, in contrast to the most common (but slower) raster scanning modalities of 2D dual axis galvanometer scanners (GSs) or Micro-Electro-Mechanical Systems (MEMS) with oscillatory mirrors. The aim of this work is to develop a graphical method, which, to our knowledge, we have introduced to determine and characterize, using a commercially-available mechanical design program (for example CATIA V5R20 (Dassault Systems, Paris, France)) to simulate the exact scan patterns of rotational Risley prisms. Both the maximum and minimum angular and linear deviations of this type of scanner are deduced theoretically to characterize the outer diameter/Field-of-View (FOV) and the inner diameter (of the blind zone) of its ring-shaped patterns, respectively. This multi-parameter analysis is performed in correlation with the shape of the scan patterns, considering the four possible configurations of laser scanners with a pair of rotational Risley prisms, as well as all their parameters: prisms angles, refractive indexes, rotational speeds, distance between the two prisms, and the distance from the system to the scanned plane. Marshall’s synthetic parameters are also considered, i.e., the ratios of the rotational velocities and of the angles of the prisms. Rules-of-thumb for designing this optomechanical scanner are extracted from this analysis, regarding both shapes and dimensions of the scan patterns to be produced. An example of experimental validation completes the mathematical analysis and the performed simulations.