Enrique Angel Rodriguez Jara

Dr. Enrique Angel Rodriguez Jara

University of Cádiz, Cádiz, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Applied Energy
Verified
Journal Article
Closed access
LRLaura Romero Rodríguez
Laura Romero Rodríguez
JLJosé Manuel Salmerón Lissen
José Manuel Salmerón Lissen
JRJose Sanchez Ramos
Jose Sanchez Ramos
Enrique Angel Rodriguez JaraEnrique Angel Rodriguez Jara
Enrique Angel Rodriguez Jara
SDServando Álvarez Domínguez
Servando Álvarez Domínguez

1 October 2016 in Energy and Buildings
Verified
Journal Article
Closed access
Enrique Angel Rodriguez JaraEnrique Angel Rodriguez Jara
Enrique Angel Rodriguez Jara
Fran SanchezFran Sanchez
Fran Sanchez
SDServando Álvarez Domínguez
Servando Álvarez Domínguez
JFJosé L. Molina Félix
José L. Molina Félix
JLJosé Manuel Salmerón Lissen
José Manuel Salmerón Lissen

9 August 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
Enrique Angel Rodriguez JaraEnrique Angel Rodriguez Jara
Enrique Angel Rodriguez Jara
Fran SanchezFran Sanchez
Fran Sanchez
SDServando Ávarez Domínguez
Servando Ávarez Domínguez
JLJosé Manuel Salmerón Lissen
José Manuel Salmerón Lissen
ACAlejandro Rincón Casado
Alejandro Rincón Casado
As microclimate modifiers, courtyards may be a good passive strategy for enhancing thermal comfort and reducing the energy demands of buildings. Thus, it is necessary to be able to quantify their tempering effect in dominant summer climates. This is frequently done using calculation methods based on CFD, but these have the drawback of their high computational cost and complexity, so their use is limited to advanced users with a high level of knowledge. Thus, an alternative is required based on a simplified method that can explain and predict the air temperature drop in courtyards. This would be extremely useful for professionals looking for the optimal design of this kind of space through energy assessment programs integrating these methods. This study proposes a simplified method of characterization that aims to identify the functional dependencies of the decrease in air temperatures in courtyards, and so to predict the air temperature inside them from that outside, if available. From the results of several experimental campaigns, three variables have been identified that characterize the decrease in the air temperature in courtyards, all of which depend on the confinement factor of the courtyard. Finally, the proposed predictive method was validated by means of an additional monitoring campaign. The results show a good fit of the calculated values to the measured ones, R2 being equal to 0.98.

23 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ÁRÁlvaro Ruíz-Pardo
Álvaro Ruíz-Pardo
Enrique Angel Rodriguez JaraEnrique Angel Rodriguez Jara
Enrique Angel Rodriguez Jara
MCMarta Conde
Marta Conde
JTJosé A. Tenorio
José A. Tenorio
Radiant floor heating is becoming increasingly popular in cold climates because it delivers higher comfort levels more efficiently than conventional systems. Wood is one of the surface coverings most frequently used in radiant flooring, despite the widely held belief that in terms of thermal performance it is no match for higher conductivity materials if a high energy performance is intended. Given that the highest admissible thermal resistance for flooring finishes or coverings is generally accepted to be 0.15 m2K/W, wood would appear to be a scantly appropriate choice. Nonetheless, the evaluation of the thermal performance of wooden radiant floor heating systems in conjunction with the building in terms of energy demand, thermal comfort, and start-up period, has been insufficiently explored in research. This has led to the present knowledge gap around its potential to deliver lower energy consumption and higher thermal comfort than high-thermal-conductivity materials, depending on building characteristics. This article studies the thermal performance of wood radiant floors in terms of three parameters: energy demand, thermal comfort, and start-up lag time, analysing the effect of wood properties in conjunction with building construction on each. An experimentally validated radiant floor model was coupled to a simplified building thermal model to simulate the performance of 60 wood coverings and one reference granite covering in 216 urban dwellings differing in construction features. The average energy demand was observed to be lower in the wood than in the granite coverings in 25% of the dwellings simulated. Similarly, on average, wood lagged behind granite in thermal comfort by less than 1 h/day in 50% of the dwellings. The energy demand was minimised in a significant 18% and thermal comfort maximised in 14% of the simulations at the lowest thermal conductivity value. The vast majority of the wooden floors lengthened the start-up lag time relative to granite in only 30 min or less in all the dwellings. Wood flooring with the highest thermal resistance (even over the 0.15 m2K/W cited in standard EN 1264-2) did not significantly affect the energy demand or thermal comfort. On average, wood flooring lowered energy demand by 6.4% and daily hours of thermal comfort by a mere 1.6% relative to granite coverings. The findings showed that wood-finished flooring may deliver comparable or, in some cases, higher thermal performance than high-conductivity material coverings, even when their thermal resistance is over 0.15 m2K/W. The suggestion is that the aforementioned value, presently deemed the maximum admissible thermal resistance, may need to be revised.

27 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Enrique Angel Rodriguez JaraEnrique Angel Rodriguez Jara
Enrique Angel Rodriguez Jara
ÁRÁlvaro Ruíz-Pardo
Álvaro Ruíz-Pardo
MCMarta Conde
Marta Conde
JTJosé A. Tenorio
José A. Tenorio
Due to its relatively lower thermal conductivity, the suitability of wood is called into question when selecting the flooring material best suited to radiant heating systems. The European standard EN 1264 considers floorings with a thermal resistance over 0.15 m2 K/W to be out of scope. This belief was partially disproved in a previous article that studied wooden floors for Madrid’s climate. However, the effect of climate still needs to be addressed. The present study extends the previous research to worldwide climates and aimed to answer the following questions: (1) Do the lowest thermal conductivity woods present good thermal performance when used in radiant floors? (2) Should the flooring have a maximum thermal resistance value? (3) Is the standard thermal resistance limit of 0.15 m2 K/W objectively justified? And (4) Do the answers of the preceding questions depend on the climate and the construction characteristics? To answer these questions, 28 cities were selected according to the Köppen–Geiger climate classification. In each city, 216 different dwellings were simulated with 60 wood floorings and one of low thermal resistance as a reference, comprising a total of 368,928 cases. Thermal performance was evaluated in terms of three parameters: energy demand, thermal comfort, and start-up lag time. Consequently, the answers to the previous questions were: (1) The lowest thermal conductivity woods can be used efficiently worldwide in radiant floor heating systems with start-up lag times close to that of the reference flooring; (2) There is no limit value for thermal resistance for floorings that can be applied to all dwellings and climates; (3) No objective justification was found for establishing a thermal resistance limit for flooring of 0.15 m2 K/W; and (4) Climate and construction characteristics can play an important role in the correct selection of flooring properties, especially in severe winters and dwellings with the greatest outdoor-exposed envelope and the worst insulation.

1 November 2020 in DYNA Ingenieria e Industria
Verified
Journal Article
Closed access
Alberto Cerezo-NarváezAlberto Cerezo-Narváez
Alberto Cerezo-Narváez
JVJosé María Piñero Vilela
José María Piñero Vilela
Enrique Angel Rodriguez JaraEnrique Angel Rodriguez Jara
Enrique Angel Rodriguez Jara
Manuel Otero-MateoManuel Otero-Mateo
Manuel Otero-Mateo
Andres Pastor-FernandezAndres Pastor-Fernandez
Andres Pastor-Fernandez
PBPablo Ballesteros-Perez
Pablo Ballesteros-Perez
Spanish residential buildings built during the real estate bubble (200-2009) complied with the Spanish Basic Building Standard on building thermal conditions NBE-CT-79. In 2006, the Basic Energy Saving Document of the Spanish Technical Building Code (CTE-DB-HE) came into effect. This code developed the Spanish Organic Law on Buildings 38/1999 and it was also much more restrictive. Recently, this regulatory framework has been updated by the Spanish Royal Decree 732/2019 on energy efficiency. This Royal Decree transposes European Directives 2010/31/EU, 2012/27/EU and 2018/844/EU on nearly-zero-energy consumption buildings (NZEB). In this paper, the energy, emissions and economic impact caused by this legislation change on a standard semi-detached house in the 153 cities of Andalusia is analyzed. In each location, the household’s original thermal behavior with the compliant with current legislation is compared. The calculations are performed with HULC energy simulation tool and the European PVGIS climate data, considering the most adverse orientations. The house adaptation involves a partial modification of the envelope, the inclusion of solar-thermal energy for the domestic hot water supply (DHW) and photovoltaic energy to reduce electricity consumption. Results show that European objectives are largely exceeded. Energy savings vary between 81% and 146%, emissions improve between 71% and 128% and the electricity and natural gas bill is reduced between 67% and 123%. Keywords: Spanish real estate bubble, energy efficiency, nearly-zero-energy building, thermal envelope, thermal insulation, solar-thermal energy, photovoltaic energy, technical building code, housing rehabilitation, Andalusia.