Halim Sghaier

Prof. Halim Sghaier

University of Monastir, Monastir, Tunisia

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SKSinda Kaziz
Sinda Kaziz
Pietro RomanoPietro Romano
Pietro Romano
Antonino ImburgiaAntonino Imburgia
Antonino Imburgia
Guido AlaGuido Ala
Guido Ala
HSHalim Sghaier
Halim Sghaier
Fares TounsiFares Tounsi
Fares Tounsi
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors’ outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made.

28 November 2014 in International Journal of Speech Technology
Verified
Journal Article
Closed access
PDF file
MNMohsen Nasri
Mohsen Nasri
AHAbdelhamid Helali
Abdelhamid Helali
HSHalim Sghaier
Halim Sghaier
HMHassen Maaref
Hassen Maaref

6 April 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
ZAZeineb Ben Abdallah
Zeineb Ben Abdallah
HSHalim Sghaier
Halim Sghaier
IGIbtissem Gammoudi
Ibtissem Gammoudi
FMFabien Moroté
Fabien Moroté
SCSébastien Cassagnère
Sébastien Cassagnère
TCTouria Cohen-Bouhacina
Touria Cohen-Bouhacina
This work describes the complete elaboration of an immunosensor for the detection of the fungal B1 aflatoxin (AFB1). In a first step, a system made of three screen-printed electrodes (SPEs) was manufactured using gold, silver/silver chloride, and carbon pastes. Raman spectroscopy showed that the thermal treatment applied to the electrodes enabled a strong decrease in the amount of undesirable organic molecules for each paste. Atomic Force Microscopy was also used to reveal the morphology of the electrode surfaces. In a second step, an autonomous and cheap electronic system was designed for the control of the sensor and electrochemical measurements, showing current variations significantly higher than those observed with a commercial system. In a last step, the gold working electrode of this system was functionalized by a simple self-assembly method, optimized in a previous work, with a molecular architecture including an antibody recognizing specifically AFB1. The complete device was finally realized by combining the SPEs and the electronic platform. The resulting setup was able to detect AFB1 toxin in a buffer with an LOD of about 50 fg/mL. It was then applied to the detection of AFB1 in rice milk, a more realistic medium comparable with those met in an agrifood context. The electrochemical detection of AFB1 was possible in a range of concentration between 0.5 pg/mL and 2.5 pg/mL, with the sensor behaving linearly in this range.

16 May 2012 in International Journal of Wireless Information Networks
Verified
Journal Article
Closed access
PDF file
MNMohsen Nasri
Mohsen Nasri
AHAbdelhamid Helali
Abdelhamid Helali
HSHalim Sghaier
Halim Sghaier
HMHassen Maaref
Hassen Maaref