Laura Favilli

Dr. Laura Favilli

Università degli Studi di Torino, Turin, Piedmont, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Frontiers in Chemistry
Verified
Journal Article
Open access
LFLaura Favilli
Laura Favilli
AGAgnese Giacomino
Agnese Giacomino
MMMery Malandrino
Mery Malandrino
Paolo InaudiPaolo Inaudi
Paolo Inaudi
ADAleandro Diana
Aleandro Diana
OAOrnella Abollino
Ornella Abollino
Mercury (Hg) and its compounds are highly toxic for humans and ecosystems, and their chemical forms determine both their behavior and transportation as well as their potential toxicity for human beings. Determining the various species of an element is therefore more crucial than understanding its overall concentration in samples. For this reason, several studies focus on the development of new analytical techniques for the identification, characterization, and quantification of Hg compounds. Commercially available, hyphenated technology, such as HPLC-ICP-MS, supports the rapid growth of speciation analysis. This review aims to summarize and critically examine different approaches for the quantification of mercury species in different samples using HPLC-ICP-MS. The steps preceding the quantification of the analyte, namely sampling and pretreatment, will also be addressed. The scenarios evaluated comprehend single and multi-element speciation analysis to create a complete guide about mercury content quantification.

27 December 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ADAleandro Diana
Aleandro Diana
SBStefano Bertinetti
Stefano Bertinetti
Ornella AbollinoOrnella Abollino
Ornella Abollino
Agnese GiacominoAgnese Giacomino
Agnese Giacomino
SBSandro Buoso
Sandro Buoso
Mery MalandrinoMery Malandrino
Mery Malandrino
In this work, an evaluation of the air of two Italian industrial cities, Turin and Biella, has been performed to identify the main sources affecting its quality and to evaluate its evolution along 15 years. These two cities are placed at the border of the Po valley, one of the most polluted areas of Europe, and the automotive and textile industries have been their main economic sectors. The elemental analysis of the PM10 collected there in 2007 has been performed by ICP-MS and ICP-AES. The results identify the urban activities and the soil/road dust resuspension as the main sources of metals. Biella was overall less polluted in PM10 than Turin, probably because of its smaller size, its smaller traffic volume, and the lower number of industries. However, the limit value imposed by the European legislation for daily average PM10 mass concentration (50 μg m−3) was frequently exceeded in the collected samples: 22% and 50%, respectively for Biella and Turin. The concentration of specific toxic metals regulated by Italian legislation was never higher than the limit value for Cd (4 ng m−3) and Pb (0.5 μg m−3), whereas it was exceeded for Ni (20 ng m−3) in 22% of the samples from Turin and only in the 5% of those from Biella. In the same way, the risk analysis, performed using the target hazard quotient (THQ), calculated for children and adult populations, did not reveal warning values. Only for Cd in children were concerning values found (median THQ = 4.9). Element concentrations showed a seasonal trend, with higher values in November and December due to a combination of stable atmospheric conditions and strengthening of anthropic sources (e.g., combustion for heat generation). Finally, data concerning the amount of Cd, Ni, and Pb in the atmosphere provided by the regional agency for environmental protection (ARPA Piedmont) have been used to follow the evolution of these elements from 2007 to 2021 in the two cities. The data reveal a significant reduction of the concentrations of all considered metals in all the sites (higher than 50%), however maintaining the seasonal variability observed in PM10 samples of 2007, with higher concentrations during the cold months and lower concentrations during the summer.

29 October 2024 in Toxics
Verified
Journal Article
Open access
PDF file
RCRiccardo Cecire
Riccardo Cecire
ADAleandro Diana
Aleandro Diana
Agnese GiacominoAgnese Giacomino
Agnese Giacomino
Ornella AbollinoOrnella Abollino
Ornella Abollino
Paolo InaudiPaolo Inaudi
Paolo Inaudi
Mery MalandrinoMery Malandrino
Mery Malandrino
Rice husk is a waste byproduct of rice production. This material has a moderate cost and is readily available, representing 20–22% of the biomass produced by rice cultivation. This study focused on the properties of rice husk in the remediation of soils contaminated by heavy metals. The effect of particle size, pH, and the presence of organic ligands on sorption efficiency was evaluated for Cd, Cu, and Mn. The continuous flow method was used to select suitable operative conditions and maximize the retention of heavy metals. Subsequently, pot experiments were carried out by growing two broadleaf plants, Lactuca sativa and Spinacia oleracea, in aliquots of soil collected in a Piedmont (Northwest Italy) site heavily contaminated by Cu, Cr, and Ni. Rice husk was added to the contaminated soil to evaluate its effectiveness in immobilizing heavy metals. The availability of Cr, Mn, Ni, Cu, Zn, Cd, and Pb in soil was studied using Tessier’s sequential extraction protocol. The content of the elements was also analyzed in plants and the uptake of heavy metals was evaluated in relation to the addition of rice husk. The growth of both plants was more efficient in the presence of rice husk due to its ability to reduce the mobility of heavy metals in the soil. The simplicity, cost-effectiveness, and scalability of its employment make the use of rice husk suitable for practical applications in soil remediation.

16 May 2022 in Molecules
Verified
Journal Article
Open access
PDF file
Paolo InaudiPaolo Inaudi
Paolo Inaudi
EMElio Mondino
Elio Mondino
Ornella AbollinoOrnella Abollino
Ornella Abollino
Mery MalandrinoMery Malandrino
Mery Malandrino
Monica ArgenzianoMonica Argenziano
Monica Argenziano
Agnese GiacominoAgnese Giacomino
Agnese Giacomino
A measurement and speciation procedure for the determination of total mercury (HgTOT), inorganic mercury (HgIN), and methylmercury (CH3Hg) was developed and the applicability for on-site determination was demonstrated. A simple, portable sample pretreatment procedure was optimized to extract the analytes. Home-made columns, packed with a new sorbent material called CYXAD (CYPHOS 101 modified Amberlite XAD), were used to separate the two forms of the analyte. HgTOT and CH3Hg were determined by anodic stripping voltammetry (ASV), using a solid gold electrode (SGE). Two certified reference materials (BCR-463 Tuna Fish and Tuna Fish ERM-CE 464) and eight fresh fishes were analyzed. Then, the results that were obtained following the optimized portable procedure were compared with the concentrations obtained, using a direct mercury analyzer (DMA). This quantification, using the two techniques, demonstrated the good performance of the proposed method.

4 March 2025 in Talanta
Verified
Journal Article
Open access
Paolo InaudiPaolo Inaudi
Paolo Inaudi
CEChristian Esposito
Christian Esposito
Mery MalandrinoMery Malandrino
Mery Malandrino
LFLaura Favilli
Laura Favilli
Agnese GiacominoAgnese Giacomino
Agnese Giacomino
Ornella AbollinoOrnella Abollino
Ornella Abollino
The aim of this study was to develop a differential pulse anodic stripping voltammetry (DPASV) method for the rapid, sensitive and cost-effective determination and speciation of inorganic arsenic in aquatic environments. The electrochemical determination of arsenite and arsenate was investigated using a rotating solid gold electrode (SGE). As(III) was selectively determined at +0.1 V by ASV after a deposition at -0.3 V. The total As content (As(V) + As(III)) was electrochemically reduced at -1.2 V by nascent hydrogen to As0, and then As(V) was evaluated indirectly by subtraction. Electrochemical reduction of As(V), instead of chemical reduction, was chosen to minimize the consumption of chemical reagents, reduce analysis time and provide a method suitable for on-site analysis. First, the operating parameters were optimized, and the method was characterized in terms of selectivity, sensitivity, linearity, precision and accuracy. A Limit of Detection (LOD) of 0.10 μg L-1 was found for the developed technique for As(tot). The method was then applied to the direct quantitative determination and speciation of inorganic arsenic in real water samples; the results obtained showed satisfactory agreement with those produced by the hydride generation technique coupled with inductively coupled plasma atomic emission spectroscopy (HG-ICP-OES). Subsequently, the voltammetric determination of arsenic was explored with a portable potentiostat to evaluate the reliability of the procedure for on-site detection.

3 November 2023 in Molecules
Verified
Journal Article
Open access
PDF file
Paolo InaudiPaolo Inaudi
Paolo Inaudi
Ornella AbollinoOrnella Abollino
Ornella Abollino
Monica ArgenzianoMonica Argenziano
Monica Argenziano
Mery MalandrinoMery Malandrino
Mery Malandrino
CGCaterina Guiot
Caterina Guiot
Agnese GiacominoAgnese Giacomino
Agnese Giacomino
Iron, a crucial element in our environment, plays a vital role in numerous natural processes. Understanding the presence and concentration of iron in the environment is very important as it impacts various aspects of our planet’s health. The on-site detection and speciation of iron are significant for several reasons. In this context, the present work aims to evaluate the applicability of voltammetry for the on-site determination of iron and its possible speciation using a portable voltammetric analyzer. Voltammetry offers the advantage of convenience and cost-effectiveness. For iron (III) determination, the modification of a glassy carbon electrode (GCE) with an antimony-bismuth film (SbBiFE) using the acetate buffer (pH = 4) as a supporting electrolyte was used. The technique adopted was Square Wave Adsoptive Cathodic Stripping Voltammetry (SW-AdCSV), and we used 1-(2-piridylazo)-2-naphthol (PAN) as the iron (III) ligand. Linearity, repeatability, detection limit, and accuracy were determined using synthetic solutions; then, a Standard Reference Material (SRM) of 1643f Trace Elements in Water (iron content: 93.44 ± 0.78 µg L−1) was used for validation measurements in the real matrix. the accuracy of this technique was found to be excellent since we obtained a recovery of 103.16%. The procedure was finally applied to real samples (tap, lake, and seawater), and the results obtained were compared via Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). The amount of iron found was 207.8 ± 6.6 µg L−1 for tap water using voltammetry and 200.9 ± 1.5 µg L−1 with ICP-OES. For lake water, 171.7 ± 3.8 µg L−1, 169.8 ± 4.1 µg L−1, and 187.5 ± 5.7 µg L−1 were found using voltammetry in the lab both on-site and using ICP-OES, respectively. The results obtained demonstrate the excellent applicability of the proposed on-site voltammetric procedure for the determination of iron and its speciation in water.