Purpose: The aim of this study was to define the subjective and objective clinical results of all-inside surgical technique at a medium-term follow-up and to compare these results with those obtained from antero-medial (AM) ACL reconstruction technique using hamstrings (HS) or bone-patellar tendon-bone (BpTB) grafts to detect eventual superiority of one technique to another. Methods: A retrospective analysis of routinely collected data was conducted. Inclusion criteria were ACL reconstruction through all-inside technique or AM technique with HS or BpTB performed between January 2015 and May 2018; age between 15 and 30 year old; minimum 24 months’ available follow-up. Exclusion criteria were contralateral ACL reconstruction; need for any other associated procedures during surgery. Clinical outcomes were assessed with KOOS, Lysholm, Tegner scores and KT-1000 device. Results: According to the selection criteria, 157 patients were enrolled and divided subsequently into 3 groups: all-inside (51 patients), AM-HS (53 patients) and AM-BpTB (53 patients). A significant postoperative improvement of each score in all groups was detected. The mean KT-1000 was 3.1 ± 1.0 mm in all-inside group, while 3.3 ± 1.4 mm and 2.5 ± 0.4 mm in AM-HS and AM-BpTB groups, respectively. Comparing the results obtained, no statistically significant difference was found between the three techniques (p = 0.27). Statistically significant differences were highlighted in surgical duration: all-inside method was the longest (117′), followed by AM-BpTB surgery (101′) and AM-HS technique (87′). Conclusions: The all-inside technique showed good postoperative results at medium-term follow-up. It could be a valuable solution for ACL reconstruction, especially in young patients due to its less invasiveness, despite surgical skills and time needed. Levels of evidence: Level IV.
Sensor technology was introduced to intraoperatively analyse the differential pressure between the medial and lateral compartments of the knee during primary TKA using a sensor to assess if further balancing procedures are needed to achieve a “balanced” knee. The prognostic role of epidemiological and radiological parameters was also analysed. A consecutive series of 21 patients with primary knee osteoarthritis were enrolled and programmed for TKA in our unit between 1 September 2020 and 31 March 2021. The VERASENSE Knee System (OrthoSensor Inc., Dania Beach, FL, USA) has been proposed as an instrument that quantifies the differential pressure between the compartments of the knee intraoperatively throughout the full range of motion during primary TKA, designed with a J-curve anatomical femoral design and a PS “medially congruent” polyethylene insert. Thirteen patients (61.90%) showed a “balanced” knee, and eight patients (38.10%) showed an intra-operative “unbalanced” knee and required additional procedures. A total of 13 additional balancing procedures were performed. At the end of surgical knee procedures, a quantitatively balanced knee was obtained in all patients. In addition, a correlation was found between the compartment pressure of phase I and phase II at 10° of flexion and higher absolute pressures were found in the medial compartment than in the lateral compartment in each ROM degree investigated. Moreover, those pressure values showed a trend to decrease with the increase in flexion degrees in both compartments. The “Kinetic Tracking” function displays the knee’s dynamic motion through the full ROM to evaluate joint kinetics. The obtained kinetic traces reproduced the knee’s medial pivot and femoral rollback, mimicking natural knee biomechanics. Moreover, we reported a statistically significant correlation between the need for soft tissue or bone resection rebalancing and severity of the initial coronal deformity (>10°) and a preoperative JLCA value >2°. The use of quantitative sensor-guided pressure evaluation during TKA leads to a more reproducible “balanced” knee. The surgeon, evaluating radiological parameters before surgery, may anticipate difficulties in knee balance and require those devices to achieve the desired result objectively.
Objective: kinematic alignment technique has been recently described as a new surgical procedure able to restore the patient specific physiological knee alignment; furthermore, new prosthesis, as medial stabilized (MS) third generation TKA, were designed to better reproduce the anatomical shape of the knee. In this prospective study, the authors evaluated early clinical improvement and radiological outcomes of patients having pre-operative small coronal limb deformity underwent TKA using a surgical technique combining a “restricted kinematic alignment” with medial stabilized polyethylene insert. Fifteen consecutive patients (8 female and 7 male) scheduled for a total knee replacement have been enrolled for this study and treated using a modern third generation knee implant with a medial congruent tibial polyethylene. Clinical improvements have been assessed pre-operatively and at 6 and 12 months Follow up (FU) using the Oxford knee Score (OKS)( Ishikawa et al., Jun. 2015) 12 the Knee Society Score (KSS)( Pinskerova and et al., Aug. 2004) 13 and Forgotten Joint Score (FJS) as patient reported outcomes measurement system (PROMs). A radiological evaluation was made by a single physician at 6 months. Average improvement in OKS was from 20.2 (SD 5.5) pre-operatively to 41.3 (SD 2.1) at the final FU. KSS pain/motion improved with a mean score from 40.1 (SD 4.0) pre-op to 89.1 (SD 6.3) while KSS function improved with an average score from 51.0 (SD 6.2) pre-op to 81.8 (SD 8.4) showing good to excellent results in all the knee treated. The mean FJS at 6 months follow up was 75.1 (SD 4.2) improving to 79.3 (SD 3.3) at one year FU. Post-operative XR showing an average varus Hip-Knee-Ankle (HKA) angle of 178.8° (range from 176° to 182°, SD 2,3°); We found no statistically significant difference between pre-operative and post-operative HKA (p < 0,05). The current authors assumed appropriate to combine a modern TKA implant designed replicating the anatomical shape of the native knee with a surgical technique able to better reproduce the physiological, patient specific, knee biomechanics. Our findings suggest that combining MS implant with KA technique may results in better short-term functional results, helping the patient to “forget” their replaced joint and restoring their pre-arthritic quality of life.
Review Article Tibial condylar valgus osteotomy for the treatment of intra-articular varus deformity of the knee Marcello Capella, Salvatore Risitano, Luigi Sabatini, Carlotta Faccenda, Luca Barberis, Daniele Camazzola, Francesco Bosco, Fortunato Giustra, Alessandro Massè