Maria Gragnaniello

Ms. Maria Gragnaniello

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Maria GragnanielloMaria Gragnaniello
Maria Gragnaniello
ALESSANDRO BORGHESEALESSANDRO BORGHESE
ALESSANDRO BORGHESE
VMVincenzo Romano Marrazzo
Vincenzo Romano Marrazzo
LMLuca Maresca
Luca Maresca
Giovanni BreglioGiovanni Breglio
Giovanni Breglio
Michele RiccioMichele Riccio
Michele Riccio
Myocardial Infarction (MI), commonly known as heart attack, is a cardiac condition characterized by damage to a portion of the heart, specifically the myocardium, due to the disruption of blood flow. Given its recurring and often asymptomatic nature, there is the need for continuous monitoring using wearable devices. This paper proposes a single-microcontroller-based system designed for the automatic detection of MI based on the Edge Computing paradigm. Two solutions for MI detection are evaluated, based on Machine Learning (ML) and Deep Learning (DL) techniques. The developed algorithms are based on two different approaches currently available in the literature, and they are optimized for deployment on low-resource hardware. A feasibility assessment of their implementation on a single 32-bit microcontroller with an ARM Cortex-M4 core was examined, and a comparison in terms of accuracy, inference time, and memory usage was detailed. For ML techniques, significant data processing for feature extraction, coupled with a simpler Neural Network (NN) is involved. On the other hand, the second method, based on DL, employs a Spectrogram Analysis for feature extraction and a Convolutional Neural Network (CNN) with a longer inference time and higher memory utilization. Both methods employ the same low power hardware reaching an accuracy of 89.40% and 94.76%, respectively. The final prototype is an energy-efficient system capable of real-time detection of MI without the need to connect to remote servers or the cloud. All processing is performed at the edge, enabling NN inference on the same microcontroller.

24 December 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Maria GragnanielloMaria Gragnaniello
Maria Gragnaniello
VMVincenzo Romano Marrazzo
Vincenzo Romano Marrazzo
ALESSANDRO BORGHESEALESSANDRO BORGHESE
ALESSANDRO BORGHESE
LMLuca Maresca
Luca Maresca
Giovanni BreglioGiovanni Breglio
Giovanni Breglio
Michele RiccioMichele Riccio
Michele Riccio
Diabetes is a chronic condition, and traditional monitoring methods are invasive, significantly reducing the quality of life of the patients. This study proposes the design of an innovative system based on a microcontroller that performs real-time ECG acquisition and evaluates the presence of diabetes using an Edge-AI solution. A spectrogram-based preprocessing method is combined with a 1-Dimensional Convolutional Neural Network (1D-CNN) to analyze the ECG signals directly on the device. By applying quantization as an optimization technique, the model effectively balances memory usage and accuracy, achieving an accuracy of 89.52% with an average precision and recall of 0.91 and 0.90, respectively. These results were obtained with a minimal memory footprint of 347 kB flash and 23 kB RAM, showcasing the system’s suitability for wearable embedded devices. Furthermore, a custom PCB was developed to validate the system in a real-world scenario. The hardware integrates high-performance electronics with low power consumption, demonstrating the feasibility of deploying Edge-AI for non-invasive, real-time diabetes detection in resource-constrained environments. This design represents a significant step forward in improving the accessibility and practicality of diabetes monitoring.

27 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ECEliana Cinotti
Eliana Cinotti
Maria GragnanielloMaria Gragnaniello
Maria Gragnaniello
Salvatore ParlatoSalvatore Parlato
Salvatore Parlato
JCJessica Centracchio
Jessica Centracchio
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
Daniele EspositoDaniele Esposito
Daniele Esposito
Atrial fibrillation (AF) is the most common type of heart rhythm disorder worldwide. Early recognition of brief episodes of atrial fibrillation can provide important diagnostic information and lead to prompt treatment. AF is mainly characterized by an irregular heartbeat. Today, many personal devices such as smartphones, smartwatches, smart rings, or small wearable medical devices can detect heart rhythm. Sensors can acquire different types of heart-related signals and extract the sequence of inter-beat intervals, i.e., the instantaneous heart rate. Various algorithms, some of which are very complex and require significant computational resources, are used to recognize AF based on inter-beat intervals (RR). This study aims to verify the possibility of using neural networks algorithms directly on a microcontroller connected to sensors for AF detection. Sequences of 25, 50, and 100 RR were extracted from a public database of electrocardiographic signals with annotated episodes of atrial fibrillation. A custom 1D convolutional neural network (1D-CNN) was designed and then validated via a 5-fold subject-wise split cross-validation scheme. In each fold, the model was tested on a set of 3 randomly selected subjects, which had not previously been used for training, to ensure a subject-independent evaluation of model performance. Across all folds, all models achieved high and stable performance, with test accuracies of 0.963 ± 0.031, 0.976 ± 0.022, and 0.980 ± 0.023, respectively, for models using 25 RR, 50 RR, and 100 RR sequences. Precision, recall, F1-score, and AUC-ROC exhibited similarly high performance, confirming robust generalization across unseen subjects. Performance systematically improved with longer RR windows, indicating that richer temporal context enhances discrimination of AF rhythm irregularities. A complete Edge AI prototype integrating a low-power ECG analog front-end, an ARM Cortex M7 microcontroller and an IoT transmitting module was utilized for realistic tests. Inferencing time, peak RAM usage, flash usage and current absorption were measured. The results obtained show the possibility of using neural network algorithms directly on microcontrollers for real-time AF recognition with very low power consumption. The prototype is also capable of sending the suspicious ECG trace to the cloud for final validation by a physician. The proposed methodology can be used for personal screening not only with ECG signals but with any other signal that reproduces the sequence of heartbeats (e.g., photoplethysmographic, pulse oximetric, pressure, accelerometric, etc.).