Md Nurunnabi

Mr. Md Nurunnabi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2019 in IEEE Access
Verified
Journal Article
Open access
MNMd Nurunnabi
Md Nurunnabi
NRNaruttam Kumar Roy
Naruttam Kumar Roy
Eklas HossainEklas Hossain
Eklas Hossain
HPHemanshu Roy Pota
Hemanshu Roy Pota
This paper presents a feasibility and sensitivity analysis of renewable energy-based off-grid and grid-connected microgrids by investigating the potentials of wind and solar energy at different areas, namely, Kuakata, Sitakunda, Magnama, Dinajpur and Rangpur in Bangladesh -a country that experiences a tropical climate. A specialized neural network algorithm has been employed to track the wind speed and solar irradiance all year round in two salient regions and the promising results have been analyzed for making the decision whether the data are reliable for forecasting or not. Four different types of models including PV-Grid, Wind-Grid, Wind-PV-Grid, and off-grid hybrid renewables are designed using the Hybrid Optimization of Multiple Energy Resources (HOMER Pro) software. By considering the key factors: net present cost, cost of energy, renewable fraction, local load demand, availability of renewable energy resources, system economics and greenhouse gas emissions, the optimal hybrid renewable energy system (HRES) configurations (Wind/PV/Grid/Battery) for the mentioned regions are determined. Various sensitivity and optimization variables, such as RE resources, local load demand, grid energy price, nominal discount rate, the life-time of wind turbine, the capacity of wind turbine, PV arrays, converter, and battery, are used to make the decision. Detailed sensitivity analyses are performed to investigate how the optimal system configurations change with a tiny variation in input variables and results show output results are more sensitive on the variations in long-term average wind speed and solar irradiance, nominal discount rate, and the lifetime of wind turbines than the other inputs which is definitely a vital finding of this investigation. Finally, considering several decision making factors, a detailed feasibility chart is presented for two distinct nominal discount rates, i.e., 9% and 10%, which depicts the economically viable renewable energy based plant size in the mentioned regions. Although the crux of this paper is based on providing low-cost electricity to people living in rural areas of Bangladesh, our propositions carry with them certain concomitant benefits, not least of which are environmental benefits and social benefits.

17 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
HDHimadry Shekhar Das
Himadry Shekhar Das
MNMd Nurunnabi
Md Nurunnabi
Mohamed Zidan Mohamed SalemMohamed Zidan Mohamed Salem
Mohamed Zidan Mohamed Salem
Shuhui LiShuhui Li
Shuhui Li
Mohammad Mominur RahmanMohammad Mominur Rahman
Mohammad Mominur Rahman
Electric vehicle grid integration (EVGI) is one of the most important parts of transportation electrification. However, large-scale EV charging/discharging can have an adverse effect on the distribution grid, due to a large amount of load being drawn from or fed back to the power grid. Additionally, the power electronics used in the grid interaction may impose additional complications, such as voltage and frequency deviation, harmonic distortion, etc. With proper control scheme designs for the grid-connected inverters, such complications can be mitigated, and several grid ancillary services, such as voltage and frequency support, reactive power support, and harmonic mitigation, can be facilitated from large-scale EVGI. In this study, a large-scale EVGI system is developed where the vector control implementation of a grid-connected inverter in the d-q reference frame is presented for providing different grid ancillary services using the EVGI system. The EVGI system is operated in different control modes to ensure multiple ancillary services of the power grid. The study is supported by the electromagnetic transient simulation performed in Matlab/Simulink of a large-scale EVGI system. The simulation shows that with the proper control mechanism of grid-connected inverters, EVGI can be used to provide several useful grid ancillary services.

28 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
MNMd Nurunnabi
Md Nurunnabi
Shuhui LiShuhui Li
Shuhui Li
The rapid rise of inverter-based resources (IBRs) such as solar, wind, and battery energy storage is transforming power grids and creating new challenges for protection. Unlike synchronous generators, many IBRs are interfaced through grid-following (GFL) inverters that operate as controlled current sources and rely on an external voltage reference, resulting in fault responses that are current-limited and controller-shaped. These characteristics reduce fault current magnitude and can undermine conventional protection schemes. In contrast, emerging grid-forming (GFM) inverters behave as voltage sources that establish local voltage and frequency, offering improved disturbance support but still transitioning to current-limited operation under severe faults. This review summarizes GFL versus GFM operating principles and deployments, compares their behavior under balanced and unbalanced faults, and evaluates protection impacts using a protection-relevant taxonomy supported by illustrative electromagnetic transient (EMT) case studies. Key challenges, including underreach/overreach of impedance-based elements, reduced overcurrent sensitivity, and directional misoperation, are identified. Mitigation options are discussed, spanning adaptive/supervised relaying, communication-assisted and differential protection, and inverter-side fault current shaping and GFM integration. The implications of IEEE 1547-2018 and IEEE 2800-2022 are reviewed to clarify ride-through and support requirements that constrain protection design in high-IBR systems.

10 September 2026 in Electronics
Verified
Journal Article
Open access
PDF file
Md Rumman RafiMd Rumman Rafi
Md Rumman Rafi
Shuhui LiShuhui Li
Shuhui Li
MNMd Nurunnabi
Md Nurunnabi
YHYang-Ki Hong
Yang-Ki Hong
ZLZhenghao Liu
Zhenghao Liu
The application of DC power electronics has expanded significantly across modern transmission and distribution systems, spanning medium-voltage direct current (MVDC) and high-voltage direct current (HVDC) networks, as well as low-power DC supplies for nanoscale applications, in which experimental validation remains indispensable for verifying system performance and control strategies. However, developing experimental platforms for high-power, high-voltage, or nanoscale DC systems is technically challenging and expensive and has not been adequately addressed in the existing literature. To overcome these limitations, this paper presents a per-unit-based experimental twin (Ex-Twin) framework for Buck converters implemented with a nested-loop control architecture. By transforming the converter dynamics from the time domain to an angular-domain representation, the proposed per-unit framework enables the development of dynamically equivalent experimental twins across a wide range of operating scales. The feasibility and effectiveness of the proposed Ex-Twin framework are validated through comprehensive electromagnetic (EMT) simulation studies and hardware experimental results, demonstrating its potential as a scalable and cost-effective platform for the development, testing, and validation of advanced DC power electronic systems. EMT simulations verify the cross-scale dynamic equivalence of the converter models over power ratings from 2 kW to 2 MW and voltage levels from 54 V to 54 kV, provided that the corresponding per-unit parameters and normalized disturbances are preserved. Under the investigated operating conditions, the systems achieved efficiencies of 95.3%, 96.7%, and 94.3% at 2 kW, 20 kW, and 2 MW, respectively, using both the real-scale and corresponding per-unit controllers. These results demonstrate consistent performance across the evaluated power scales. In addition, laboratory tests conducted on a 1 kW, 50 V Buck-converter platform validate the real-time implementation of both the real-scale and per-unit controllers under reference-voltage and load disturbances. An experimentally measured efficiency of 92.1% was achieved with both controllers, further demonstrating their consistent performance.

18 April 2026 in Electronics
Verified
Journal Article
Open access
PDF file
BKBishal Karmakar
Bishal Karmakar
Shuhui LiShuhui Li
Shuhui Li
MNMd Nurunnabi
Md Nurunnabi
Data-center power lines are nearing their thermal and operational limits, creating a need for higher transfer capability, lower voltage regulation, and improved transmission efficiency. Although series capacitor compensation is a well-established transmission technique, its application to large data-center interconnections requires a clearer understanding of how compensation level affects controllable power delivery under practical voltage regulation requirements. This paper develops analytical transmission-line models without and with series compensation and applies them to the grid-to-data-center transmission interface. The study quantifies how series compensation affects voltage regulation, reactive power requirement, transferable power, and transmission efficiency under two operating regimes: an unconstrained receiving-end voltage case and a constrained terminal-voltage case. The results show that, when the receiving-end voltage is not strictly regulated, increasing the degree of series compensation significantly reduces voltage regulation and reactive power demand while enhancing power transfer capability. However, when the sending-end and receiving-end voltages are constrained to remain at or near nominal values, the maximum transferable power increases only up to an optimal compensation level, beyond which it declines as compensation approaches 100%. The analysis further shows that coordinated regulation of voltage magnitude and angle becomes necessary at high compensation levels to maintain controllable and efficient power transfer. Overall, the paper provides a data-center-oriented framework for identifying when series compensation improves power delivery and when additional transmission control becomes necessary.