Mihaela Claudia Spataru

Mrs. Mihaela Claudia Spataru

Iasi University of Life Sciences (IULS), Iaşi, Romania

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Liliana VerestiucLiliana Verestiuc
Liliana Verestiuc
MSMihaela Claudia Spataru
Mihaela Claudia Spataru
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
MBMaria Butnaru
Maria Butnaru
CSCarmen Solcan
Carmen Solcan
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu

10 March 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
BIBaltatu Iustinian
Baltatu Iustinian
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
MVMaria Daniela Vlad
Maria Daniela Vlad
MSMihaela Claudia Spataru
Mihaela Claudia Spataru
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Metals that come into contact with the body can cause reactions in the body, so biomaterials must be tested to avoid side effects. Mo, Zr, and Ta are non-toxic elements; alloyed with titanium, they have very good biocompatibility properties and mechanical properties. The paper aims to study an original Ti20Mo7ZrxTa system (5, 10, 15 wt %) from a mechanical and in vitro biocompatibility point of view. Alloys were examined by optical microstructure, tensile strength, fractographic analysis, and in vitro assay. The obtained results indicate very good mechanical and biological properties, recommending them for future orthopedic medical applications.

10 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
MSMihaela Claudia Spataru
Mihaela Claudia Spataru
FCFlorina Daniela Cojocaru
Florina Daniela Cojocaru
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
CSCarmen Solcan
Carmen Solcan
Ioana A. DuceacIoana A. Duceac
Ioana A. Duceac
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Ti-based alloys are widely used in medical applications. When implant devices are used to reconstruct disordered bone, prevent bone resorption and enhance good bone remodeling, the Young’s modulus of implants should be close to that of the bone. To satisfy this requirement, many titanium alloys with different biocompatible elements (Zr, Ta, Mo, Si etc.) interact well with adjacent bone tissues, promoting an adequate osseointegration. Four new different alloys were obtained and investigated regarding their microstructure, mechanical, chemical and biological behavior (in vitro and in vivo evaluation), as follows: Ti20Mo7Zr15Ta, Ti20Mo7Zr15Ta0.5Si, Ti20Mo7Zr15Ta0.75Si and Ti20Mo7Zr15TaSi. 60 days after implantation, both in control and experimental rabbits, at the level of implantation gap and into the periimplant area were found the mesenchymal stem cells which differentiate into osteoblasts, then osteocytes and osteoclasts which are involved in the new bone synthesis and remodeling, the periimplant fibrous capsule being continued by newly spongy bone tissue, showing a good osseointegration of alloys. A 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay confirmed the in vitro cytocompatibility of the prepared alloys.

8 November 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
CSCarmen Solcan
Carmen Solcan
LHLuminita Diana Hritcu
Luminita Diana Hritcu
MSMihaela Claudia Spataru
Mihaela Claudia Spataru
Biomaterials are currently a unique class of materials that are essential to improving the standard of human life and extending it. In the assent of the appearance of biomaterials that contain non-toxic elements, in this study, we examine a system of Ti25Mo7Zr15TaxSi (x = 0, 0.5, 0.75, 1 wt.%) for future medical applications. The alloys were developed in a vacuum electric arc furnace and then studied from a structural, mechanical and in vivo assessment (on rabbits) perspective. The effect of the silicon addition was clearly seen in both the structural and the mechanical characteristics, standing out as beta alloys with a dendritic structure and lowering the mechanical properties as a result of the silicon addition. In experimental rabbits, the proliferation of mesenchymal stem cells was observed in the periosteum and peri-implant area, differentiating into osteoblasts and then into osteocytes. Osteoclasts were discovered within the cartilaginous islands that provide structural support to newly formed bone, playing a primary role in bone remodeling. The newly formed spongy tissue adhered to the fibrous capsule that surrounds the alloy, ensuring good osseointegration of metallic implants. The overexpression of Osteopontin, Metalloproteinase-2 (also known as gelatinase A), and Metallopeptidase-9 (also known as gelatinase B) underscores the processes of osteogenesis, bone mineralization, and normal bone remodeling.

7 January 2024 in Animals
Verified
Journal Article
Open access
PDF file
NMNicoleta Manuta
Nicoleta Manuta
BÇBuket Çakar
Buket Çakar
Ozan GündemirOzan Gündemir
Ozan Gündemir
MSMihaela Claudia Spataru
Mihaela Claudia Spataru
Studies on the structure of the distal phalanx help explain the development of laminitis. Additionally, examining the structure of the distal phalanx from a taxonomic perspective also contributes to veterinary anatomy. In this study, we examined shape variation in the medial and lateral distal phalanx of both fore- and hindlimbs using the geometric morphometry method. We investigated whether the shape of the distal phalanx differed between phalanx positions and how much of the shape variation in this bone depends on size. For this purpose, distal phalanges from 20 Holstein cattle were used, and the bones were digitized in 3D. A draft containing 176 semi-landmarks was prepared for shape analysis, and this draft was applied to all samples using automated landmarking through point cloud alignment and correspondence analysis. A principal component analysis was performed to obtain general patterns of morphological variation. The centroid size (CS) was employed as an approximation of size. Although distal phalanx groups generally showed close variations, PC1 statistically separated the hindlimb lateral distal phalanx (HL) and the forelimb medial distal phalanx (FM) from each other in shape. While PC2 separated HL from other distal phalanx groups, PC3 separated fore- and hindlimb groups. The shape (Procrustes distance) of the hindlimb medial distal phalanx (HM) is markedly less variable than the other three phalanges. The smallest distal phalanx in size was HL. For both forelimb and hindlimb, the medial distal phalanges were larger than the lateral ones. Size (CS) was found to have an effect on PC1 and PC3. In this study, a reference model of the same breeds for distal phalanx was created. These results can provide useful information, especially in terms of veterinary anatomy, zooarchaeology, and paleontology.

17 July 2024 in Animals
Verified
Journal Article
Open access
PDF file
BÇBuket Çakar
Buket Çakar
Faruk TandirFaruk Tandir
Faruk Tandir
BGBarış can Guzel
Barış can Guzel
CBCaner Bakıcı
Caner Bakıcı
BÜBurak Ünal
Burak Ünal
Ozan GündemirOzan Gündemir
Ozan Gündemir
This study aimed to reveal the morphological characteristics of pure Holstein and Simmental skulls and to obtain reference values for morphometric analysis. Moreover, 54 skulls from 12- to 14-month-old male Holstein (n = 25) and Simmental (n = 29) cattle were collected from Turkey’s Southeastern Anatolia Region between 2023 and 2024. Linear measurements indicated that Holsteins had longer skulls compared to Simmentals. Holsteins exhibited significantly higher values for the greatest length of nasals and the shortest skull length. The facial breadth was wider in Holsteins and statistically distinctive between the breeds. Holsteins had a more oval orbital bony roof, while Simmentals exhibited a wider orbital structure. The orbital index was higher in Holsteins, distinguishing between the two breeds. It was observed that Simmental cattle had a wider occipital region. This difference is likely due to the larger lateral appearance of the Simmental skull, which has more body weight and provides a larger surface area for muscle attachment. These differences not only aid in breed identification but also offer insights into the functional adaptations of each breed. Future research should explore the genetic and environmental factors contributing to these morphological traits, further enriching our knowledge of cattle morphology and its implications for breeding and conservation efforts.